Domonkos Nagy
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Domonkos Nagy has a total of 65 co-authors. Here are the top co-authors by number of shared publications:
- Daniel Refy
HUN-REN Centre for Energy Research
6 shared publications - Miklos Vecsei
Centre for Energy Research, Budapest, Hungary
4 shared publications - Sandor Zoletnik
HUN-REN Centre for Energy Research 1 , Budapest
4 shared publications - Barnabás Csillag
HUN-REN Centre for Energy Research, 1121 Budapest, Hungary
3 shared publications - Erik Walcz
Ctr Energy Res, Budapest, Hungary
3 shared publications - Gábor Anda
HUN-REN Centre for Energy Research, Institute for Atomic Energy Research 1 , Konkoly-Thege M. út 29-33, Budapest 1121
3 shared publications
Latest Publications
- Open Access
- 29 September 2026
- Published by Elsevier in SSRN Electronic Journal
Magnetic Field Compatibility Experiments of Ultrafast, Eddy Current Driven Actuators- ITER DMS Fast Shutter and ITER DMS Support Laboratory Propellant Valve Tests
Ultrafast actuators in the ITER Disruption Mitigation System must operate reliably in external magnetic fields while providing reproducible pellet launch and propellant gas suppression. This study investigates the magnetic-field compatibility of an eddy-current-driven fast propellant valve and fast shutter at the ITER Static Magnetic Field Test Facility. Magnetic-field scans and repeated-actuation tests were performed to assess performance sensitivity, repeatability and thermal effects. The valve exhibited a material-dependent reduction in expelled gas amount with increasing field strength. This reduction could be compensated by a modest increase in capacitor charging voltage, demonstrating sufficient actuation margin under the expected operating conditions. Initial valve pressure and actuator temperature were also identified as relevant factors affecting gas delivery. The shutter showed only weak magnetic-field sensitivity, maintaining reproducible millisecond closure and impact-free braking during extended operation. Neither device exhibited measurable field-related functional degradation during the campaign. These results support the use of eddy-current actuators in the ITER magnetic environment and provide experimental design inputs for the ITER DMS Propellant Valve Prototype, while demonstrating the suitability of the fast shutter concept for fusion applications.
- 29 September 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessMagnetic Field Compatibility Experiments of Ultrafast, Eddy Current Driven Actuators- ITER DMS Fast Shutter and ITER DMS Support Laboratory Propellant Valve Tests
Ultrafast actuators in the ITER Disruption Mitigation System must operate reliably in external magnetic fields while providing reproducible pellet launch and propellant gas suppression. This study investigates the magnetic-field compatibility of an eddy-current-driven fast propellant valve and fast shutter at the ITER Static Magnetic Field Test Facility. Magnetic-field scans and repeated-actuation tests were performed to assess performance sensitivity, repeatability and thermal effects. The valve exhibited a material-dependent reduction in expelled gas amount with increasing field strength. This reduction could be compensated by a modest increase in capacitor charging voltage, demonstrating sufficient actuation margin under the expected operating conditions. Initial valve pressure and actuator temperature were also identified as relevant factors affecting gas delivery. The shutter showed only weak magnetic-field sensitivity, maintaining reproducible millisecond closure and impact-free braking during extended operation. Neither device exhibited measurable field-related functional degradation during the campaign. These results support the use of eddy-current actuators in the ITER magnetic environment and provide experimental design inputs for the ITER DMS Propellant Valve Prototype, while demonstrating the suitability of the fast shutter concept for fusion applications.
- Open Access
- 21 May 2025
- Published by Elsevier in Fusion Engineering and Design
- Vol. 218
Validation of a new propellant valve test bed to support developments for shattered pellet injection technology
- 21 May 2025
- Published by Elsevier in Fusion Engineering and Design
- Vol. 218
Open AccessValidation of a new propellant valve test bed to support developments for shattered pellet injection technology
- 6 September 2024
- Published by Elsevier in Fusion Engineering and Design
- Vol. 208
Analysis of pellet propellant gas expansion in the test bench of the ITER DMS Support Laboratory
- 6 September 2024
- Published by Elsevier in Fusion Engineering and Design
- Vol. 208
Analysis of pellet propellant gas expansion in the test bench of the ITER DMS Support Laboratory
- Open Access
- 7 August 2024
- Published by IOP Publishing in Nuclear Fusion
- Vol. 64 (9) , 096033
Production and launch studies of cryogenic pellets for the ITER disruption mitigation system
A support laboratory has been set up to study pellet production, launch and shattering of cryogenic protium, deuterium, and neon pellets for the ITER disruption mitigation system, which plans to use 28.5 × 57 mm (diameter × length) protium, neon an mixture pellets in the Shattered Pellet Injectors. Such large protium pellets have not been produced and launched before, therefore the desublimation and launch process have been studied in detail in two steps. First 19 mm diameter pellets were produced, followed by the demonstration of the final pellet size. Pellet desublimation recipes were established for all pellet types, and it was found that, under certain conditions, even the large neon pellets can be launched with a propellant gas pulse, without requiring a mechanical punch device. This is attributed to cryogenic snow formation on the surface of the pellet. Conditions for the snow formation are studied and tendencies are understood using simple calculations.
- 7 August 2024
- Published by IOP Publishing in Nuclear Fusion
- Vol. 64 (9) , 096033
Open AccessProduction and launch studies of cryogenic pellets for the ITER disruption mitigation system
A support laboratory has been set up to study pellet production, launch and shattering of cryogenic protium, deuterium, and neon pellets for the ITER disruption mitigation system, which plans to use 28.5 × 57 mm (diameter × length) protium, neon an mixture pellets in the Shattered Pellet Injectors. Such large protium pellets have not been produced and launched before, therefore the desublimation and launch process have been studied in detail in two steps. First 19 mm diameter pellets were produced, followed by the demonstration of the final pellet size. Pellet desublimation recipes were established for all pellet types, and it was found that, under certain conditions, even the large neon pellets can be launched with a propellant gas pulse, without requiring a mechanical punch device. This is attributed to cryogenic snow formation on the surface of the pellet. Conditions for the snow formation are studied and tendencies are understood using simple calculations.
- Open Access
- 1 July 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (7)
Charge exchange recombination spectroscopy on the alkali beam of Wendelstein 7-X
Measurements of ion temperature profiles are required to assess the energy and particle transport processes in the Wendelstein 7-X stellarator. This device is equipped with a diagnostic alkali beam, which can be utilized to determine local impurity temperatures and densities by Charge Exchange Recombination Spectroscopy (CXRS). It could provide such profiles in the edge plasma, where other diagnostics are less efficient. With this contribution, first results of CXRS measurements on the sodium beam from the scientific operation phase OP2.1 are presented. The spectroscopic system was in commissioning phase lacking some of the final optical components. Thus, the aim of the diagnostics during this campaign was to explore the measurement capabilities. Based on the processed spectra, the prospects of C5+ and C6+ ion temperature and concentration measurements are discussed. The results indicate that with the final optical setup under installation, the diagnostics could provide ion temperature profiles in the edge with 3 mm radial resolution and at least 1 s temporal resolution.
- 1 July 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (7)
Open AccessCharge exchange recombination spectroscopy on the alkali beam of Wendelstein 7-X
Measurements of ion temperature profiles are required to assess the energy and particle transport processes in the Wendelstein 7-X stellarator. This device is equipped with a diagnostic alkali beam, which can be utilized to determine local impurity temperatures and densities by Charge Exchange Recombination Spectroscopy (CXRS). It could provide such profiles in the edge plasma, where other diagnostics are less efficient. With this contribution, first results of CXRS measurements on the sodium beam from the scientific operation phase OP2.1 are presented. The spectroscopic system was in commissioning phase lacking some of the final optical components. Thus, the aim of the diagnostics during this campaign was to explore the measurement capabilities. Based on the processed spectra, the prospects of C5+ and C6+ ion temperature and concentration measurements are discussed. The results indicate that with the final optical setup under installation, the diagnostics could provide ion temperature profiles in the edge with 3 mm radial resolution and at least 1 s temporal resolution.
- Open Access
- 29 March 2024
- Published by Elsevier in Fusion Engineering and Design
- Vol. 202
Eddy current actuated fast valve development for disruption mitigation applications
- 29 March 2024
- Published by Elsevier in Fusion Engineering and Design
- Vol. 202
Open AccessEddy current actuated fast valve development for disruption mitigation applications
- Open Access
- 24 November 2023
- Published by IOP Publishing in Nuclear Fusion
- Vol. 64 (1) , 016017
Statistical analysis of plasma filaments in the island divertor of Wendelstein 7-X
Plasma filaments have been measured with alkali beam emission spectroscopy in the plasma edge, divertor island, and scrape-off layer of Wendelstein 7-X. Due to the high intensity of a 1–2 kHz plasma mode, a new, correlation based conditional averaging algorithm was used to search for filaments in the signals. With that method, effects of different magnetic configurations and density levels on filament properties are observed. In configurations where the islands are small and do not play an important role for the connection length topology, filaments behave similar to tokamaks. In contrast, in configurations with larger magnetic islands and more complex connection length profiles, filaments behave quite differently, for instance they may or may not appear in the inner side of the divertor island depending on the plasma parameters. Coupling between the filaments and lower frequency events are also showed. The role of filaments in the global and local particle transport is briefly discussed.
- 24 November 2023
- Published by IOP Publishing in Nuclear Fusion
- Vol. 64 (1) , 016017
Open AccessStatistical analysis of plasma filaments in the island divertor of Wendelstein 7-X
Plasma filaments have been measured with alkali beam emission spectroscopy in the plasma edge, divertor island, and scrape-off layer of Wendelstein 7-X. Due to the high intensity of a 1–2 kHz plasma mode, a new, correlation based conditional averaging algorithm was used to search for filaments in the signals. With that method, effects of different magnetic configurations and density levels on filament properties are observed. In configurations where the islands are small and do not play an important role for the connection length topology, filaments behave similar to tokamaks. In contrast, in configurations with larger magnetic islands and more complex connection length profiles, filaments behave quite differently, for instance they may or may not appear in the inner side of the divertor island depending on the plasma parameters. Coupling between the filaments and lower frequency events are also showed. The role of filaments in the global and local particle transport is briefly discussed.
- Open Access
- 18 January 2023
- Published by MDPI AG in Journal of Nuclear Engineering
- Vol. 4 (1) , 142-151
Development of the W7-X Alkali Metal Beam Diagnostic Observation System for OP2
On a Wendelstein 7-X (W7-X), an alkali metal beam (AMB) diagnostic system was installed in order to measure the plasma edge electron density profiles and turbulence transport. A sodium beam was injected in the plasma, and the light emission was observed by an optical system. During the last operation phase, OP1.2b campaign trial spectral measurements were performed with a dedicated optical branch. The results showed the emergence of potential CX lines in the light spectra during sodium injection. The lines were identified as Carbon III, which were the dominant lines observed by other diagnostics at the edge plasma. Based on these results, an additional dedicated optical system was developed and installed in 2021 for the upcoming operational phase, OP2. The optics were designed for multiple purposes: spectral measurements for the AMB system and for a He/Ne gas jet. The system was designed to allow implementation of further diagnostics on this port later (e.g., coherence imaging system). The details of the implementation of the design requirements and the main challenges of the manufacturing process and installation are discussed in this paper.
- 18 January 2023
- Published by MDPI AG in Journal of Nuclear Engineering
- Vol. 4 (1) , 142-151
Open AccessDevelopment of the W7-X Alkali Metal Beam Diagnostic Observation System for OP2
On a Wendelstein 7-X (W7-X), an alkali metal beam (AMB) diagnostic system was installed in order to measure the plasma edge electron density profiles and turbulence transport. A sodium beam was injected in the plasma, and the light emission was observed by an optical system. During the last operation phase, OP1.2b campaign trial spectral measurements were performed with a dedicated optical branch. The results showed the emergence of potential CX lines in the light spectra during sodium injection. The lines were identified as Carbon III, which were the dominant lines observed by other diagnostics at the edge plasma. Based on these results, an additional dedicated optical system was developed and installed in 2021 for the upcoming operational phase, OP2. The optics were designed for multiple purposes: spectral measurements for the AMB system and for a He/Ne gas jet. The system was designed to allow implementation of further diagnostics on this port later (e.g., coherence imaging system). The details of the implementation of the design requirements and the main challenges of the manufacturing process and installation are discussed in this paper.
- 1 September 2021
- Published by Elsevier in Fusion Engineering and Design
- Vol. 170, 112501
Strength estimation of the ITER Lower Vertical Neutron Camera at thermal loading
- 1 September 2021
- Published by Elsevier in Fusion Engineering and Design
- Vol. 170, 112501
Strength estimation of the ITER Lower Vertical Neutron Camera at thermal loading