GAGábor Anda

Gábor Anda

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Gábor Anda has a total of 48 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Formation of molecular gas jets for proton beam characterization

    by A. Zsákai, G. Anda, D. Ferenczy, G. Pokol

    Beam profile measurements on the ECR microwave H+ ion source at HUN-REN CER have been conducted using a 45°-inclined Faraday cup and an infrared camera. While this setup allows for current and spatial distribution measurements, its resolution is limited by the IR camera and thermal diffusion on Faraday cup’s surface. Emittance has been evaluated through simulations, but no direct measurements are yet available. To address this, a gas-jet-based, non-invasive diagnostic system is being developed to measure both the beam profile and emittance without affecting source performance. Among various diagnostic options—such as scintillating screens, optical transition radiation screen, and residual gas techniques—the gas-jet approach was selected for its robustness under high beam power. The system uses an injector nozzle and skimmers to form a supersonic molecular gas curtain with a thickness of 1–2 mm, a transverse size of 10 × 10 mm2, and a density in the range of 1016−1017particlesm3. As the beam passes through the curtain, it excites the gas atoms (e.g., Ne and Ar), producing photon emission captured by a camera. With proper calibration, this allows reconstruction of the beam current profile. Introducing a mesh before the curtain enables emittance measurement via beamlet formation. This paper presents a semi-analytical model for gas curtain formation and density evolution, along with a design case study tailored to the HUN-REN CER proton ion source.


  • Design and preliminary results of the microwave-driven proton ion source developed at the Center for Energy Research

    by G. Anda, D. Czémán, M. Lampert, M. Miklós, D. Oravecz, A. Zsákai

    A novel medium-current (up to 20 mA), low normalized beam emittance (<1 π mm mrad) electron cyclotron resonance microwave H+ ion source has been developed at the Center for Energy Research in Budapest, Hungary. This high-stability design targets an energy ripple below 1% while delivering a continuous or pulsed proton beam with adjustable pulse duration (0.1–10 ms) and frequency (0.01–40 Hz) at 35 keV beam energy. The design includes a microwave generator, a four-stub tuner, an E-bend, a DC break, a vacuum window, and a four-section matching transformer connected to a 90 mm diameter, 100 mm long cylindrical ionizing chamber. The magnetic field is generated by six axially aligned permanent magnet bars. Additionally, fifteen 4 mm-diameter holes allow discharge observation, pressure monitoring, and gas inlet placement. Magnetic simulations guided the layout of the permanent magnets and ferromagnetic components to shape the desired field. Beam simulations confirmed the feasibility of appropriate focusing. High-voltage insulators are mounted radially to minimize the gap between the extraction slit and ion optics. Experimental tests demonstrated stable beam extraction up to ∼6 mA at ∼250 W microwave power using a 2 mm aperture radius. A novel high-voltage beam chopper was also tested, achieving beam switch-off within ∼10 µs and enabling controlled time-structured beam operation. These results confirm the ion source’s potential for integration into compact accelerator-based neutron generators, targeting applications such as boron neutron capture therapy and materials science investigations.

  • Open Access

    Tunable, unmountable, permanent-magnet-based accelerator magnet

    by Dániel Barna, Gábor Anda

    This paper presents the concept and design of a novel accelerator magnet consisting of two concentric rings of permanent magnets arranged in a Halbach layout. By replacing one component, the device can be converted to any transverse multipole configuration. By the individual rotation of the two rings, both the strength and the direction of the field pattern can be continuously tuned in a wide range, including the special case of polarity reversal. The tuning range can be changed by a parametric change of the design. The device is split into two halves and can be easily opened to allow for its installation and removal around an existing beampipe. The performance of a quadrupole demonstrator prototype is presented, including measurement results of field quality, integrated gradient and hysteresis, and discussion of sensitivity to the remanent magnetization of the permanent magnets.


  • Analysis of pellet propellant gas expansion in the test bench of the ITER DMS Support Laboratory

    by M. Vécsei, G. Anda, G. Bartók, G. Gárdonyi, S. Jachmich, I. Katona, D. Nagy, D. Oravecz, D. Réfy, T. Szepesi, et al.

  • Validation of the synthetic model for the imaging heavy ion beam probe at the ASDEX Upgrade tokamak (invited)

    by P. Oyola, G. Birkenmeier, H. Lindl, J. Galdon-Quiroga, J. Rueda-Rueda, E. Viezzer, A. Rodriguez-Gonzalez, J. Hidalgo-Salaverri, M. Garcia-Munoz, B. Tal, et al.

    Recent experiments at the ASDEX Upgrade tokamak have provided the first ever measurements from the imaging heavy-ion beam probe. In this work, we show that the developed simulation framework can reproduce qualitatively the measurement’s observed shape and position. Quantitatively, we demonstrate that the model reproduces, within the experimental uncertainties, the observed signal levels. A detailed explanation of the synthetic model is presented, along with the calibration of the optical setup that reproduces the measurements.


  • Open Access

    Charge exchange recombination spectroscopy on the alkali beam of Wendelstein 7-X

    by B. G. Csillag, G. Anda, G. Cseh, D. Dunai, O. P. Ford, E. Flom, D. Gradic, F. Henke, M. Krychowiak, D. Nagy, et al.

    Measurements of ion temperature profiles are required to assess the energy and particle transport processes in the Wendelstein 7-X stellarator. This device is equipped with a diagnostic alkali beam, which can be utilized to determine local impurity temperatures and densities by Charge Exchange Recombination Spectroscopy (CXRS). It could provide such profiles in the edge plasma, where other diagnostics are less efficient. With this contribution, first results of CXRS measurements on the sodium beam from the scientific operation phase OP2.1 are presented. The spectroscopic system was in commissioning phase lacking some of the final optical components. Thus, the aim of the diagnostics during this campaign was to explore the measurement capabilities. Based on the processed spectra, the prospects of C5+ and C6+ ion temperature and concentration measurements are discussed. The results indicate that with the final optical setup under installation, the diagnostics could provide ion temperature profiles in the edge with 3 mm radial resolution and at least 1 s temporal resolution.


  • Open Access

    Development of the W7-X Alkali Metal Beam Diagnostic Observation System for OP2

    by Domonkos Nagy, Sándor Zoletnik, Matthias Otte, Miklós Vécsei, Maciej Krychowiak, Ralf König, Dániel Dunai, Gábor Anda, Sándor Hegedűs, Barnabás Csillag, et al.

    On a Wendelstein 7-X (W7-X), an alkali metal beam (AMB) diagnostic system was installed in order to measure the plasma edge electron density profiles and turbulence transport. A sodium beam was injected in the plasma, and the light emission was observed by an optical system. During the last operation phase, OP1.2b campaign trial spectral measurements were performed with a dedicated optical branch. The results showed the emergence of potential CX lines in the light spectra during sodium injection. The lines were identified as Carbon III, which were the dominant lines observed by other diagnostics at the edge plasma. Based on these results, an additional dedicated optical system was developed and installed in 2021 for the upcoming operational phase, OP2. The optics were designed for multiple purposes: spectral measurements for the AMB system and for a He/Ne gas jet. The system was designed to allow implementation of further diagnostics on this port later (e.g., coherence imaging system). The details of the implementation of the design requirements and the main challenges of the manufacturing process and installation are discussed in this paper.