Mariana E. Smith
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Mariana E. Smith has a total of 27 co-authors. Here are the top co-authors by number of shared publications:
- Alan Kuntz
Robotics Center and the Kahlert School of Computing, University of Utah, Salt Lake City, UT, USA
3 shared publications - Axel Krieger
Department of Mechanical Engineering, Johns Hopkins University, Baltimore, USA
3 shared publications - Anton Deguet
Laboratory for Computational Sensing and Robotics, Johns Hopkins University, Baltimore, MD, USA
2 shared publications - Nural Yilmaz
Johns Hopkins University, Baltimore, USA
2 shared publications - Paul Maria Scheikl
Johns Hopkins University
2 shared publications - Adam May
Department of Biomedical Engineering Johns Hopkins University Baltimore Maryland USA
1 shared publication
Latest Publications
- 22 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Robotics and Bionics
- Vol. 8 (1) , 188-197
Integrating Learned Retraction and Model-Based Resection Planning for Automated Central Airway Obstruction Removal
Surgeon shortages have driven significant recent advances in robotic surgical assistance. To progress toward surgical automation, we address transoral central airway obstruction (CAO) removal, selecting this procedure for its relatively constrained environment and clear clinical objectives. Prior work has demonstrated successful CAO removal with single-port, minimally invasive robotic systems, making it a promising target for autonomy. We present a new autonomous system designed for CAO removal that integrates a learning-based tissue retraction policy with a model-based resection planner, deployed on a bimanual robotic platform with vision guidance. While our long-term motivation is minimally invasive intervention, we evaluate our approach in an open-surgery setting, enabling rapid development and testing. We evaluate our system in 12 ex vivo CAO removal procedures running at three distinct levels of autonomy. Our results indicate that the learned retraction policy performs similarly or better than a manually designed heuristic, with a mean surgeon-rated score (1-10) of 8.0± 1.6 compared to 6.8± 2.5, and a mean percent tumor volume removal of 113.9± 18.8% compared to 111.9± 13.3%. The model-based resections performed best when supervised, resulting in less tissue damage and better cutting accuracy. Furthermore, our approach produced clinically successful outcomes in all eight supervised autonomous trials. Notably, in one case, the system achieved complete tumor removal without any human intervention. Our overall findings underscore the importance of high-level supervision, revealing targets for future automation.
- 22 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Robotics and Bionics
- Vol. 8 (1) , 188-197
Integrating Learned Retraction and Model-Based Resection Planning for Automated Central Airway Obstruction Removal
Surgeon shortages have driven significant recent advances in robotic surgical assistance. To progress toward surgical automation, we address transoral central airway obstruction (CAO) removal, selecting this procedure for its relatively constrained environment and clear clinical objectives. Prior work has demonstrated successful CAO removal with single-port, minimally invasive robotic systems, making it a promising target for autonomy. We present a new autonomous system designed for CAO removal that integrates a learning-based tissue retraction policy with a model-based resection planner, deployed on a bimanual robotic platform with vision guidance. While our long-term motivation is minimally invasive intervention, we evaluate our approach in an open-surgery setting, enabling rapid development and testing. We evaluate our system in 12 ex vivo CAO removal procedures running at three distinct levels of autonomy. Our results indicate that the learned retraction policy performs similarly or better than a manually designed heuristic, with a mean surgeon-rated score (1-10) of 8.0± 1.6 compared to 6.8± 2.5, and a mean percent tumor volume removal of 113.9± 18.8% compared to 111.9± 13.3%. The model-based resections performed best when supervised, resulting in less tissue damage and better cutting accuracy. Furthermore, our approach produced clinically successful outcomes in all eight supervised autonomous trials. Notably, in one case, the system achieved complete tumor removal without any human intervention. Our overall findings underscore the importance of high-level supervision, revealing targets for future automation.
- 14 July 2025
- Published by World Scientific Pub Co Pte Ltd in Journal of Medical Robotics Research
- Vol. 10 (03n04)
Autonomous Vision-Guided Resection of Central Airway Obstruction
Existing tracheal tumor resection methods often lack the precision required for effective airway clearance, and robotic advancements offer new potential for autonomous resection. We present a vision-guided, autonomous approach for palliative resection of tracheal tumors. This system models the tracheal surface with a fifth-degree polynomial to plan tool trajectories, while a custom Faster R-CNN segmentation pipeline identifies the trachea and tumor boundaries. The electrocautery tool angle is optimized using handheld surgical demonstrations, and trajectories are planned to maintain a 1[ ]mm safety clearance from the tracheal surface. We validated the workflow successfully in five consecutive experiments on ex-vivo animal tissue models, successfully clearing the airway obstruction without trachea perforation in all cases (with more than 90% volumetric tumor removal). These results support the feasibility of an autonomous resection platform, paving the way for future developments in minimally-invasive autonomous resection.
- 14 July 2025
- Published by World Scientific Pub Co Pte Ltd in Journal of Medical Robotics Research
- Vol. 10 (03n04)
Autonomous Vision-Guided Resection of Central Airway Obstruction
Existing tracheal tumor resection methods often lack the precision required for effective airway clearance, and robotic advancements offer new potential for autonomous resection. We present a vision-guided, autonomous approach for palliative resection of tracheal tumors. This system models the tracheal surface with a fifth-degree polynomial to plan tool trajectories, while a custom Faster R-CNN segmentation pipeline identifies the trachea and tumor boundaries. The electrocautery tool angle is optimized using handheld surgical demonstrations, and trajectories are planned to maintain a 1[ ]mm safety clearance from the tracheal surface. We validated the workflow successfully in five consecutive experiments on ex-vivo animal tissue models, successfully clearing the airway obstruction without trachea perforation in all cases (with more than 90% volumetric tumor removal). These results support the feasibility of an autonomous resection platform, paving the way for future developments in minimally-invasive autonomous resection.
- 27 July 2024
- Published by World Scientific Pub Co Pte Ltd in Journal of Medical Robotics Research
- Vol. 09 (03n04)
MagnetoStalsis: Generating Peristalsis in an Artificial Bowel for Treatment of Short Bowel Syndrome
Efforts to develop an artificial intestine for treatment of short bowel syndrome have thus far failed to achieve coordinated peristalsis. To address this, we introduce an implantable, biomimetic, magnetically-actuated peristaltic pumping apparatus. The system consists of a magnetic pump surrounding an intestinal graft and a rotating external magnetic field generator that produces peristaltic motion in the graft as the field direction alternates. We performed computational finite element modeling to simulate deformation and stress concentration on the pump. We then tested the ability of the system to produce fluid flow through porcine subintestinal submucosa at actuation frequencies from 0 Hz to 4 Hz. The system achieved a maximal flow rate of 6.03 mL/min at 3 Hz actuation frequency, which is in the physiological range of human intestinal flow rates. This device represents a novel proof-of-concept for achieving untethered peristalsis in an implantable intestinal graft that is primed for preclinical testing in animal models of short bowel syndrome.
- 27 July 2024
- Published by World Scientific Pub Co Pte Ltd in Journal of Medical Robotics Research
- Vol. 09 (03n04)
MagnetoStalsis: Generating Peristalsis in an Artificial Bowel for Treatment of Short Bowel Syndrome
Efforts to develop an artificial intestine for treatment of short bowel syndrome have thus far failed to achieve coordinated peristalsis. To address this, we introduce an implantable, biomimetic, magnetically-actuated peristaltic pumping apparatus. The system consists of a magnetic pump surrounding an intestinal graft and a rotating external magnetic field generator that produces peristaltic motion in the graft as the field direction alternates. We performed computational finite element modeling to simulate deformation and stress concentration on the pump. We then tested the ability of the system to produce fluid flow through porcine subintestinal submucosa at actuation frequencies from 0 Hz to 4 Hz. The system achieved a maximal flow rate of 6.03 mL/min at 3 Hz actuation frequency, which is in the physiological range of human intestinal flow rates. This device represents a novel proof-of-concept for achieving untethered peristalsis in an implantable intestinal graft that is primed for preclinical testing in animal models of short bowel syndrome.
- 13 April 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 8 (6) , 3494-3501
Toward Continuum Robot Tentacles for Lung Interventions: Exploring Folding Support Disks
Toward the future goal of creating a lung surgery system featuring multiple tentacle-like robots, we present a new folding concept for continuum robots that enables them to squeeze through openings smaller than the robot's nominal diameter (e.g., the narrow space between adjacent ribs). This is facilitated by making the disks along the robot's backbone foldable.We also demonstrate that such a robot can feature not only straight, but also curved tendon routing paths, thereby achieving a diverse family of conformations. We find that the foldable robot performs comparably, from a kinematic perspective, to an identical non-folding continuum robot at varying deployment lengths. This work paves the way for future applications with a continuum robot that can fold and fit through smaller openings, with the potential to reduce invasiveness during surgical tasks.
- 13 April 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 8 (6) , 3494-3501
Toward Continuum Robot Tentacles for Lung Interventions: Exploring Folding Support Disks
Toward the future goal of creating a lung surgery system featuring multiple tentacle-like robots, we present a new folding concept for continuum robots that enables them to squeeze through openings smaller than the robot's nominal diameter (e.g., the narrow space between adjacent ribs). This is facilitated by making the disks along the robot's backbone foldable.We also demonstrate that such a robot can feature not only straight, but also curved tendon routing paths, thereby achieving a diverse family of conformations. We find that the foldable robot performs comparably, from a kinematic perspective, to an identical non-folding continuum robot at varying deployment lengths. This work paves the way for future applications with a continuum robot that can fold and fit through smaller openings, with the potential to reduce invasiveness during surgical tasks.