MSMariana E. Smith

Mariana E. Smith

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Mariana E. Smith has a total of 27 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Integrating Learned Retraction and Model-Based Resection Planning for Automated Central Airway Obstruction Removal

    by Tanner Watts, Mariana Smith, James Ferguson, Nural Yilmaz, Paul Maria Scheikl, Bao Thach, Brendan Burkhart, Tucker Hermans, Anton Deguet, Axel Krieger, et al.

    Surgeon shortages have driven significant recent advances in robotic surgical assistance. To progress toward surgical automation, we address transoral central airway obstruction (CAO) removal, selecting this procedure for its relatively constrained environment and clear clinical objectives. Prior work has demonstrated successful CAO removal with single-port, minimally invasive robotic systems, making it a promising target for autonomy. We present a new autonomous system designed for CAO removal that integrates a learning-based tissue retraction policy with a model-based resection planner, deployed on a bimanual robotic platform with vision guidance. While our long-term motivation is minimally invasive intervention, we evaluate our approach in an open-surgery setting, enabling rapid development and testing. We evaluate our system in 12 ex vivo CAO removal procedures running at three distinct levels of autonomy. Our results indicate that the learned retraction policy performs similarly or better than a manually designed heuristic, with a mean surgeon-rated score (1-10) of 8.0± 1.6 compared to 6.8± 2.5, and a mean percent tumor volume removal of 113.9± 18.8% compared to 111.9± 13.3%. The model-based resections performed best when supervised, resulting in less tissue damage and better cutting accuracy. Furthermore, our approach produced clinically successful outcomes in all eight supervised autonomous trials. Notably, in one case, the system achieved complete tumor removal without any human intervention. Our overall findings underscore the importance of high-level supervision, revealing targets for future automation.


  • Autonomous Vision-Guided Resection of Central Airway Obstruction

    by Mariana E. Smith, Nural Yilmaz, Tanner Watts, Paul Maria Scheikl, Jiawei Ge, Anton Deguet, Alan Kuntz, Axel Krieger

    Existing tracheal tumor resection methods often lack the precision required for effective airway clearance, and robotic advancements offer new potential for autonomous resection. We present a vision-guided, autonomous approach for palliative resection of tracheal tumors. This system models the tracheal surface with a fifth-degree polynomial to plan tool trajectories, while a custom Faster R-CNN segmentation pipeline identifies the trachea and tumor boundaries. The electrocautery tool angle is optimized using handheld surgical demonstrations, and trajectories are planned to maintain a 1[ ]mm safety clearance from the tracheal surface. We validated the workflow successfully in five consecutive experiments on ex-vivo animal tissue models, successfully clearing the airway obstruction without trachea perforation in all cases (with more than 90% volumetric tumor removal). These results support the feasibility of an autonomous resection platform, paving the way for future developments in minimally-invasive autonomous resection.


  • MagnetoStalsis: Generating Peristalsis in an Artificial Bowel for Treatment of Short Bowel Syndrome

    by Mariana E. Smith, Adam May, Trevor Schwehr, Onder Erin, Cody Tragesser, Daniel Scheese, Lamar O. Mair, Yancy Diaz-Mercado, David Hackam, Axel Krieger

    Efforts to develop an artificial intestine for treatment of short bowel syndrome have thus far failed to achieve coordinated peristalsis. To address this, we introduce an implantable, biomimetic, magnetically-actuated peristaltic pumping apparatus. The system consists of a magnetic pump surrounding an intestinal graft and a rotating external magnetic field generator that produces peristaltic motion in the graft as the field direction alternates. We performed computational finite element modeling to simulate deformation and stress concentration on the pump. We then tested the ability of the system to produce fluid flow through porcine subintestinal submucosa at actuation frequencies from 0 Hz to 4 Hz. The system achieved a maximal flow rate of 6.03 mL/min at 3 Hz actuation frequency, which is in the physiological range of human intestinal flow rates. This device represents a novel proof-of-concept for achieving untethered peristalsis in an implantable intestinal graft that is primed for preclinical testing in animal models of short bowel syndrome.


  • Toward Continuum Robot Tentacles for Lung Interventions: Exploring Folding Support Disks

    by Margaret Rox, Daniel S. Esser, Mariana E. Smith, Tayfun Efe Ertop, Maxwell Emerson, Fabien Maldonado, Erin A. Gillaspie, Alan Kuntz, Robert J. Webster

    Toward the future goal of creating a lung surgery system featuring multiple tentacle-like robots, we present a new folding concept for continuum robots that enables them to squeeze through openings smaller than the robot's nominal diameter (e.g., the narrow space between adjacent ribs). This is facilitated by making the disks along the robot's backbone foldable.We also demonstrate that such a robot can feature not only straight, but also curved tendon routing paths, thereby achieving a diverse family of conformations. We find that the foldable robot performs comparably, from a kinematic perspective, to an identical non-folding continuum robot at varying deployment lengths. This work paves the way for future applications with a continuum robot that can fold and fit through smaller openings, with the potential to reduce invasiveness during surgical tasks.