Fang Liu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Fang Liu has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
- Jiaqi Lu
Southwest Jiaotong University
2 shared publications - Kun Tang
School of Information Science and Technology, Southwest Jiaotong University, Chengdu, China
2 shared publications - Xiang Yu
School of Information Science and Technology, Southwest Jiaotong University, Chengdu, China
2 shared publications - Xiangdong Chen
Southwest Jiaotong University
2 shared publications - Xing Ding
School of Information Science and Technology, Southwest Jiaotong University, Chengdu, China
2 shared publications Chenghua Xie
The school of information science and technology, Southwest Jiaotong University, Chengdu, China
1 shared publication
Latest Publications
- Open Access
- 18 January 2025
- Published by Springer Nature in Communications Engineering
- Vol. 4 (1) , 1-11
Ultrafast humidity sensor and transient humidity detections in high dynamic environments
Limited by the adsorption and diffusion rate of water molecules, traditional humidity sensors, such as those based on polymer electrolytes, porous ceramics, and metal oxides, typically have long response times, which hinder their application in monitoring transient humidity changes. Here we present an ultrafast humidity sensor with a millisecond-level response. The sensor is prepared by assembling monolayer graphene oxide quantum dots on silica microspheres using a simple electrostatic self-assembly technique. Benefiting from the joint action of the micro spheres and the ultrathin humidity-sensitive film, it displays the fastest response time (2.76 ms) and recovery time (12.4 ms) among electronic humidity sensors. With the ultrafast response of the sensor, we revealed the correlation between humidity changes in speech airflow and speech activities, demonstrated the noise immunity of humidity speech activity detection, confirmed the humidity shock caused by explosions, realized ultrahigh frequency respiratory monitoring, and verified the effect of humidity-triggering in the non-invasive ventilator. This ultrafast humidity sensor has broad application prospects in monitoring transient humidity changes.
- 18 January 2025
- Published by Springer Nature in Communications Engineering
- Vol. 4 (1) , 1-11
Open AccessUltrafast humidity sensor and transient humidity detections in high dynamic environments
Limited by the adsorption and diffusion rate of water molecules, traditional humidity sensors, such as those based on polymer electrolytes, porous ceramics, and metal oxides, typically have long response times, which hinder their application in monitoring transient humidity changes. Here we present an ultrafast humidity sensor with a millisecond-level response. The sensor is prepared by assembling monolayer graphene oxide quantum dots on silica microspheres using a simple electrostatic self-assembly technique. Benefiting from the joint action of the micro spheres and the ultrathin humidity-sensitive film, it displays the fastest response time (2.76 ms) and recovery time (12.4 ms) among electronic humidity sensors. With the ultrafast response of the sensor, we revealed the correlation between humidity changes in speech airflow and speech activities, demonstrated the noise immunity of humidity speech activity detection, confirmed the humidity shock caused by explosions, realized ultrahigh frequency respiratory monitoring, and verified the effect of humidity-triggering in the non-invasive ventilator. This ultrafast humidity sensor has broad application prospects in monitoring transient humidity changes.
- 25 April 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 23 (11) , 11547-11553
Highly Sensitive QCM Humidity Sensor Based on Fullerenol-Assisted Dispersion of Nafion/MWCNTs Composites
Water seepage of building walls is a common problem in our lives. However, the lack of early seepage detection methods often makes the problem worse. To develop effective early wall seepage detection methods, an ultra-sensitive quartz crystal microbalance (QCM) humidity sensor based on fullerenol (C 60 -OH)-assisted dispersion of Nafion/multi-walled carbon nanotubes (MWCNTs) composites is proposed. The prepared sensor shows almost 7 times higher frequency shift than pure Nafion-based sensor, which reaches -10814 Hz. This is mainly attributed to the uniform dispersion of MWCNTs in the Nafion with the assistance of C 60 -OH to form a reticular structure that generates more voids, which greatly improves the diffusion ability of water molecules in the composite materials and thus further enhances humidity sensing properties of the sensor. The high-performance QCM humidity sensor is expected to be used for early detection of water seepage in building walls by monitoring air humidity changes near the wall surface.
- 25 April 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 23 (11) , 11547-11553
Highly Sensitive QCM Humidity Sensor Based on Fullerenol-Assisted Dispersion of Nafion/MWCNTs Composites
Water seepage of building walls is a common problem in our lives. However, the lack of early seepage detection methods often makes the problem worse. To develop effective early wall seepage detection methods, an ultra-sensitive quartz crystal microbalance (QCM) humidity sensor based on fullerenol (C 60 -OH)-assisted dispersion of Nafion/multi-walled carbon nanotubes (MWCNTs) composites is proposed. The prepared sensor shows almost 7 times higher frequency shift than pure Nafion-based sensor, which reaches -10814 Hz. This is mainly attributed to the uniform dispersion of MWCNTs in the Nafion with the assistance of C 60 -OH to form a reticular structure that generates more voids, which greatly improves the diffusion ability of water molecules in the composite materials and thus further enhances humidity sensing properties of the sensor. The high-performance QCM humidity sensor is expected to be used for early detection of water seepage in building walls by monitoring air humidity changes near the wall surface.