Siyong Kim
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Siyong Kim has a total of 104 co-authors. Here are the top co-authors by number of shared publications:
Tianjun Ma
Department of Radiation Oncology School of Medicine Virginia Commonwealth University Health System Richmond Virginia USA
6 shared publications- Mateb Al Khalifa
Department of Radiation Oncology Virginia Commonwealth University Richmond Virginia USA
5 shared publications - William Youngjae Song
Department of Radiation Oncology Virginia Commonwealth University Richmond Virginia USA
5 shared publications - Haya Aljuaid
Department of Radiation Oncology Virginia Commonwealth University Richmond Virginia USA
3 shared publications Lulin Yuan
Department of Radiation Oncology Virginia Commonwealth University Richmond Virginia USA
3 shared publicationsMark Ostyn
Department of Radiation Oncology, Medical Physics Graduate Program, School of Medicine, Virginia Commonwealth University, Richmond, VA, 23298, USA
3 shared publications
Latest Publications
- Open Access
- 30 June 2026
- Published by Wiley in Medical Physics
- Vol. 53 (7) , e70549
Development and evaluation of an in vivo dose‐based monitoring system for electron FLASH radiation therapy
Background: FLASH radiotherapy requires further preclinical and clinical investigation to establish its biological effectiveness and define optimal beam parameters. In conventional (CONV) radiotherapy, redundant beam termination systems are a cornerstone ensuring patient safety, yet analogous safeguards for FLASH delivery are not well established, creating a critical barrier to safely enabling such studies. Purpose: To develop and evaluate a real‐time, in vivo, point‐dose monitoring system capable of terminating electron FLASH beam delivery as an additional monitoring system on a modified medical linear accelerator (LINAC). Methods: A decommissioned LINAC was modified to deliver electron FLASH beams with stable dose per pulse (DPP) at 300 Hz pulse frequency. A commercial plastic scintillation detector system was adapted through hardware and firmware modifications to enable pulse‐based and dose‐based beam termination via the LINAC MLC interface. The detector was cross‐calibrated against radiochromic film under FLASH conditions. System performance was evaluated through measurements of control accuracy, and detector response as a function of DPP. Results: Stable electron FLASH delivery was achieved with an average dose rate of 127.514.91 Gy/s and an approximate beam energy of 5.2 MeV. Pulse‐based control terminated delivery within +3 pulses of the requested value (requested 1‐20 pulses), with overshoot attributable to downstream circuitry latency. Dose‐based control agreed with film measurements within 1.110.81 Gy for surface‐based control (in vivo setup) and −1.450.38 Gy at depth (stable dosimetry) (tested dose deliveries between 2‐15 Gy). The detector response versus DPP in the FLASH range (0.11–0.78 Gy/p) could be roughly approximated as linear before detector saturation, with only marginal improvement seen when using quadratic fitting. Conclusion: A modified scintillation‐based system was implemented as a real‐time in vivo beam termination mechanism for electron FLASH radiotherapy under stable DPP and specific experimental conditions. While not intended for primary beam control, the system may provide a practical redundant safety layer for mitigating gross delivery errors in experimental and translational FLASH applications.
- 30 June 2026
- Published by Wiley in Medical Physics
- Vol. 53 (7) , e70549
Open AccessDevelopment and evaluation of an in vivo dose‐based monitoring system for electron FLASH radiation therapy
Background: FLASH radiotherapy requires further preclinical and clinical investigation to establish its biological effectiveness and define optimal beam parameters. In conventional (CONV) radiotherapy, redundant beam termination systems are a cornerstone ensuring patient safety, yet analogous safeguards for FLASH delivery are not well established, creating a critical barrier to safely enabling such studies. Purpose: To develop and evaluate a real‐time, in vivo, point‐dose monitoring system capable of terminating electron FLASH beam delivery as an additional monitoring system on a modified medical linear accelerator (LINAC). Methods: A decommissioned LINAC was modified to deliver electron FLASH beams with stable dose per pulse (DPP) at 300 Hz pulse frequency. A commercial plastic scintillation detector system was adapted through hardware and firmware modifications to enable pulse‐based and dose‐based beam termination via the LINAC MLC interface. The detector was cross‐calibrated against radiochromic film under FLASH conditions. System performance was evaluated through measurements of control accuracy, and detector response as a function of DPP. Results: Stable electron FLASH delivery was achieved with an average dose rate of 127.514.91 Gy/s and an approximate beam energy of 5.2 MeV. Pulse‐based control terminated delivery within +3 pulses of the requested value (requested 1‐20 pulses), with overshoot attributable to downstream circuitry latency. Dose‐based control agreed with film measurements within 1.110.81 Gy for surface‐based control (in vivo setup) and −1.450.38 Gy at depth (stable dosimetry) (tested dose deliveries between 2‐15 Gy). The detector response versus DPP in the FLASH range (0.11–0.78 Gy/p) could be roughly approximated as linear before detector saturation, with only marginal improvement seen when using quadratic fitting. Conclusion: A modified scintillation‐based system was implemented as a real‐time in vivo beam termination mechanism for electron FLASH radiotherapy under stable DPP and specific experimental conditions. While not intended for primary beam control, the system may provide a practical redundant safety layer for mitigating gross delivery errors in experimental and translational FLASH applications.
- Open Access
- 14 February 2026
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 27 (2) , e70488
Acceptance testing of a 0.35 T MR‐Linac: procedures, QA baseline, and system limitations
Purpose: This study describes and evaluates the acceptance procedure for a ViewRay (VR) MRIdian 0.35T MR‐Linac, emphasizing key challenges, limitations, and recommendations to enhance clinical performance and accuracy. Methods: A comprehensive acceptance test was conducted at a single institution, following the manufacturer's protocols and aligned with established acceptance guidelines. Specific tools and phantoms were used to assess three primary components: mechanical, dosimetric, and Magnetic Resonance Imaging (MRI). Results: Overall, the test outcomes satisfied the manufacturer's specifications. However, certain issues were identified: high couch attenuation at specific gantry angles (leading to their exclusion from treatment), variations in magnetic field homogeneity at different gantry angles, and discrepancies between TPS calculations and measurements for field output factors smaller than 0.83 cm × 0.83 cm. Conclusion: This work provides a detailed account of the acceptance testing procedure and establishes a QA baseline for 0.35T MR‐Linac systems. In doing so, it also identifies key system limitations, such as couch attenuation, magnetic field inhomogeneity, and small‐field output discrepancies, underscoring the need for careful gantry angle selection, field homogeneity optimization, and meticulous validation of very small fields.
- 14 February 2026
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 27 (2) , e70488
Open AccessAcceptance testing of a 0.35 T MR‐Linac: procedures, QA baseline, and system limitations
Purpose: This study describes and evaluates the acceptance procedure for a ViewRay (VR) MRIdian 0.35T MR‐Linac, emphasizing key challenges, limitations, and recommendations to enhance clinical performance and accuracy. Methods: A comprehensive acceptance test was conducted at a single institution, following the manufacturer's protocols and aligned with established acceptance guidelines. Specific tools and phantoms were used to assess three primary components: mechanical, dosimetric, and Magnetic Resonance Imaging (MRI). Results: Overall, the test outcomes satisfied the manufacturer's specifications. However, certain issues were identified: high couch attenuation at specific gantry angles (leading to their exclusion from treatment), variations in magnetic field homogeneity at different gantry angles, and discrepancies between TPS calculations and measurements for field output factors smaller than 0.83 cm × 0.83 cm. Conclusion: This work provides a detailed account of the acceptance testing procedure and establishes a QA baseline for 0.35T MR‐Linac systems. In doing so, it also identifies key system limitations, such as couch attenuation, magnetic field inhomogeneity, and small‐field output discrepancies, underscoring the need for careful gantry angle selection, field homogeneity optimization, and meticulous validation of very small fields.
- Open Access
- 13 January 2026
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 12 (1) , 015044
HU variation with various positions in field of view (FOV) and bit-depth in CT simulation
This study aims to investigate the impact of position-dependent CT number variations and image bit-depth, which determines the range of encodable CT numbers, on relative electron density (RED) conversion, a process essential for accurate radiation dose calculation, for patients with high-Z materials or metal implants. A commercially available phantom containing tissue-equivalent rods and metal implant inserts was scanned using a clinical CT simulator at nine positional offsets (isocenter, ±6.5 cm, and ±10.5 cm in lateral and anterior-posterior directions). CT images were acquired with both 12-bit and 16-bit scanning modes under identical scanning conditions. HU values for each insert were measured across positions and converted to RED using the clinical HU-to-RED calibration curve. HU deviations increased with positional displacement, particularly in high-density materials such as titanium and stainless steel. In 12-bit datasets, HU saturation at 3071 HU led to errors in the RED underestimation, while 16-bit imaging preserved accurate HU values even at off-center positions. Off-center positioning and bit-depth limitations significantly affect HU representation and RED conversion, especially with high-Z materials. Adoption of 16-bit acquisition or manual assignment of electron density values is recommended to prevent HU saturation and further ensure robust dose calculation. These findings highlight the importance of imaging bit depth and patient centering as part of routine radiotherapy quality assurance, particularly for cases involving metallic implants or off-isocenter targets.
- 13 January 2026
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 12 (1) , 015044
Open AccessHU variation with various positions in field of view (FOV) and bit-depth in CT simulation
This study aims to investigate the impact of position-dependent CT number variations and image bit-depth, which determines the range of encodable CT numbers, on relative electron density (RED) conversion, a process essential for accurate radiation dose calculation, for patients with high-Z materials or metal implants. A commercially available phantom containing tissue-equivalent rods and metal implant inserts was scanned using a clinical CT simulator at nine positional offsets (isocenter, ±6.5 cm, and ±10.5 cm in lateral and anterior-posterior directions). CT images were acquired with both 12-bit and 16-bit scanning modes under identical scanning conditions. HU values for each insert were measured across positions and converted to RED using the clinical HU-to-RED calibration curve. HU deviations increased with positional displacement, particularly in high-density materials such as titanium and stainless steel. In 12-bit datasets, HU saturation at 3071 HU led to errors in the RED underestimation, while 16-bit imaging preserved accurate HU values even at off-center positions. Off-center positioning and bit-depth limitations significantly affect HU representation and RED conversion, especially with high-Z materials. Adoption of 16-bit acquisition or manual assignment of electron density values is recommended to prevent HU saturation and further ensure robust dose calculation. These findings highlight the importance of imaging bit depth and patient centering as part of routine radiotherapy quality assurance, particularly for cases involving metallic implants or off-isocenter targets.
- Open Access
- 27 November 2025
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 26 (12) , e70400
Linear accelerator (linac) downtime analysis assisted with a Large Language Model (LLM)
Background: Linear accelerators (LINACs) are critical components of modern radiation therapy, requiring consistent operational performance to ensure uninterrupted patient care. Unplanned downtime not only disrupts clinical workflows but can significantly impact treatment efficacy. Traditional approaches to LINAC reliability analysis have often focused on specific components rather than comprehensive performance patterns. The advent of artificial intelligence and large language models (LLMs) offers new opportunities for analyzing complex, unstructured maintenance data to extract meaningful insights that can inform maintenance strategies and improve clinical operations. Purpose: This study aims to analyze long‐term operational performance of LINACs by investigating 10 years of maintenance records from three VarianTrueBeam LINACs. We sought to identify fault patterns, quantify downtime durations, determine the most vulnerable components, and evaluate the impact of the COVID‐19 pandemic on maintenance practices. Methods: We analyzed 1584 maintenance reports from three Varian TrueBeam LINACs spanning 4–13 years of operational use. Our analysis workflow consisted of three main stages: (1) Data normalization involved extracting and cleaning reports from multiple versions of service documents into a uniform tabular structure; (2) Report classification utilized an LLM with custom prompt engineering to categorize each report into predefined work type and failure type categories; and (3) Descriptive analysis examined patterns and trends in machine performance, including time series decomposition to identify seasonal trends and detailed analysis of service events requiring external technician involvement. Results: All LINACs consistently maintained operational downtime within the 5% threshold agreed upon with the vendor, with only one instance approaching this limit in 2021. Collimation systems, control hardware, and power systems accounted for the highest proportion of maintenance cases. Replacement and repair were the most common work categories. No consistent increasing trend in failure frequency with machine age was observed, and seasonal pattern analysis showed weak seasonality. Field service engineer (FSE) visits have increased steadily over time, with replacement tasks most frequently requiring external technician support. Post‐2020 maintenance showed increased average work hours in most categories compared to pre‐2020, particularly for replacement‐related activities. Conclusions: Our findings provide insights into the operational performance of LINACs over time, with implications for clinical budget management and maintenance scheduling. The data analysis methodology and LLM‐based classification techniques developed in this study demonstrate an effective approach to analyzing historical maintenance records that could be applied at other institutions.
- 27 November 2025
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 26 (12) , e70400
Open AccessLinear accelerator (linac) downtime analysis assisted with a Large Language Model (LLM)
Background: Linear accelerators (LINACs) are critical components of modern radiation therapy, requiring consistent operational performance to ensure uninterrupted patient care. Unplanned downtime not only disrupts clinical workflows but can significantly impact treatment efficacy. Traditional approaches to LINAC reliability analysis have often focused on specific components rather than comprehensive performance patterns. The advent of artificial intelligence and large language models (LLMs) offers new opportunities for analyzing complex, unstructured maintenance data to extract meaningful insights that can inform maintenance strategies and improve clinical operations. Purpose: This study aims to analyze long‐term operational performance of LINACs by investigating 10 years of maintenance records from three VarianTrueBeam LINACs. We sought to identify fault patterns, quantify downtime durations, determine the most vulnerable components, and evaluate the impact of the COVID‐19 pandemic on maintenance practices. Methods: We analyzed 1584 maintenance reports from three Varian TrueBeam LINACs spanning 4–13 years of operational use. Our analysis workflow consisted of three main stages: (1) Data normalization involved extracting and cleaning reports from multiple versions of service documents into a uniform tabular structure; (2) Report classification utilized an LLM with custom prompt engineering to categorize each report into predefined work type and failure type categories; and (3) Descriptive analysis examined patterns and trends in machine performance, including time series decomposition to identify seasonal trends and detailed analysis of service events requiring external technician involvement. Results: All LINACs consistently maintained operational downtime within the 5% threshold agreed upon with the vendor, with only one instance approaching this limit in 2021. Collimation systems, control hardware, and power systems accounted for the highest proportion of maintenance cases. Replacement and repair were the most common work categories. No consistent increasing trend in failure frequency with machine age was observed, and seasonal pattern analysis showed weak seasonality. Field service engineer (FSE) visits have increased steadily over time, with replacement tasks most frequently requiring external technician support. Post‐2020 maintenance showed increased average work hours in most categories compared to pre‐2020, particularly for replacement‐related activities. Conclusions: Our findings provide insights into the operational performance of LINACs over time, with implications for clinical budget management and maintenance scheduling. The data analysis methodology and LLM‐based classification techniques developed in this study demonstrate an effective approach to analyzing historical maintenance records that could be applied at other institutions.
- Open Access
- 24 October 2025
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 26 (11) , e70320
Development of a digital energy modulation framework in projectional radiography
Purpose: Digital energy modulation is a novel framework with the potential to enhance projectional x‐ray imaging by enabling translation between different x‐ray energy domains. We evaluate the feasibility of integrating machine learning methods into this approach by leveraging digitally reconstructed radiographs (DRRs) generated from dual‐energy CT datasets. Methods: DRRs were created in 15° increments from 0° to 90°, producing 3500 images per energy domain (2 polyenergetic, 4 monoenergetic). A supervised deep‐learning approach was used to train models for energy translation, focusing on conversions between polyenergetic domains and from polyenergetic to monoenergetic images. Model performance was assessed using peak signal‐to‐noise ratio (PSNR), structural similarity index (SSIM), mean squared error (MSE), and mean absolute percentage error (MAPE). Cross‐validation and projection‐specific dataset splits were used for evaluation. Results: The models trained using cross‐validation on the various energy translations achieved the following results: PSNR: 29.1 ± 2.0, SSIM: 0.947 ± 0.017, MSE: 169.1 ± 68.3, MAPE: 8.2% ± 1.8%. When translating between polyenergetic high‐energy and low‐energy domains in projection‐specific datasets (anterior‐posterior [0°] and lateral [90°] views), models achieved the following results: PSNR: 27.4 ± 0.5, SSIM: 0.909 ± 0.003, MSE: 195.9 ± 39.7, MAPE: 10.4% ± 2.1%. Conclusion: These findings demonstrate the feasibility of a digital energy modulation framework for projectional x‐ray imaging using machine learning for energy translation. The results support the potential of this approach to enhance projectional x‐ray imaging, though future work is needed to refine the models and further explore clinical applications.
- 24 October 2025
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 26 (11) , e70320
Open AccessDevelopment of a digital energy modulation framework in projectional radiography
Purpose: Digital energy modulation is a novel framework with the potential to enhance projectional x‐ray imaging by enabling translation between different x‐ray energy domains. We evaluate the feasibility of integrating machine learning methods into this approach by leveraging digitally reconstructed radiographs (DRRs) generated from dual‐energy CT datasets. Methods: DRRs were created in 15° increments from 0° to 90°, producing 3500 images per energy domain (2 polyenergetic, 4 monoenergetic). A supervised deep‐learning approach was used to train models for energy translation, focusing on conversions between polyenergetic domains and from polyenergetic to monoenergetic images. Model performance was assessed using peak signal‐to‐noise ratio (PSNR), structural similarity index (SSIM), mean squared error (MSE), and mean absolute percentage error (MAPE). Cross‐validation and projection‐specific dataset splits were used for evaluation. Results: The models trained using cross‐validation on the various energy translations achieved the following results: PSNR: 29.1 ± 2.0, SSIM: 0.947 ± 0.017, MSE: 169.1 ± 68.3, MAPE: 8.2% ± 1.8%. When translating between polyenergetic high‐energy and low‐energy domains in projection‐specific datasets (anterior‐posterior [0°] and lateral [90°] views), models achieved the following results: PSNR: 27.4 ± 0.5, SSIM: 0.909 ± 0.003, MSE: 195.9 ± 39.7, MAPE: 10.4% ± 2.1%. Conclusion: These findings demonstrate the feasibility of a digital energy modulation framework for projectional x‐ray imaging using machine learning for energy translation. The results support the potential of this approach to enhance projectional x‐ray imaging, though future work is needed to refine the models and further explore clinical applications.
- Open Access
- 9 September 2025
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 26 (9) , e70247
Clinical comparison of four commercial MRI phantoms on a 0.35T MR‐linac using a standard clinical TRUFI sequence at a single institution
Purpose: Real‑time magnetic resonance–guided radiation therapy (MRgRT) integrates MRI with a linear accelerator (Linac) for gating and adaptive radiotherapy, which requires robust image‑quality assurance over a large field of view (FOV). Specialized phantoms capable of accommodating this extensive FOV are therefore essential. This study compares the performance of four commercial MRI phantoms on a 0.35 T MR‑Linac. Methods: Four phantoms: the IBA QUASAR Insight Phantom, the IBA QUASAR MRID 3D Geometric Distortion Phantom, the MagPhan Phantom, and the Sun Nuclear Large Field MRI Distortion Phantom, were evaluated on a 0.35 T MR‐Linac using the TRUFI clinical sequence. Mean distortions were measured at gantry angles from 0° to 360° in 30° increments. Clinical imaging parameters (signal‐to‐noise ratio, uniformity, resolution via modulation transfer function, laser alignment, and twist) were also assessed where applicable. Results: The QUASAR MRID 3D Phantom enabled separate quantification of B 0 and gradient‐induced distortions but showed a notable vertical offset, which did not affect comparisons with other phantoms. Both the MagPhan and QUASAR Insight phantoms provided mean distortion measurements as well as additional imaging parameters (e.g., signal‐to‐noise ratio, uniformity, resolution). The Sun Nuclear Phantom exhibited higher overall distortion values. Conclusion: All four phantoms successfully measured distortion at multiple gantry angles on a 0.35 T MR‐Linac. The QUASAR MRID 3D Phantom uniquely differentiated B 0 from gradient distortions but required an offset adjustment. The MagPhan and QUASAR Insight phantoms offered comprehensive imaging metrics, while the Sun Nuclear Phantom exhibited relatively higher distortions.
- 9 September 2025
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 26 (9) , e70247
Open AccessClinical comparison of four commercial MRI phantoms on a 0.35T MR‐linac using a standard clinical TRUFI sequence at a single institution
Purpose: Real‑time magnetic resonance–guided radiation therapy (MRgRT) integrates MRI with a linear accelerator (Linac) for gating and adaptive radiotherapy, which requires robust image‑quality assurance over a large field of view (FOV). Specialized phantoms capable of accommodating this extensive FOV are therefore essential. This study compares the performance of four commercial MRI phantoms on a 0.35 T MR‑Linac. Methods: Four phantoms: the IBA QUASAR Insight Phantom, the IBA QUASAR MRID 3D Geometric Distortion Phantom, the MagPhan Phantom, and the Sun Nuclear Large Field MRI Distortion Phantom, were evaluated on a 0.35 T MR‐Linac using the TRUFI clinical sequence. Mean distortions were measured at gantry angles from 0° to 360° in 30° increments. Clinical imaging parameters (signal‐to‐noise ratio, uniformity, resolution via modulation transfer function, laser alignment, and twist) were also assessed where applicable. Results: The QUASAR MRID 3D Phantom enabled separate quantification of B 0 and gradient‐induced distortions but showed a notable vertical offset, which did not affect comparisons with other phantoms. Both the MagPhan and QUASAR Insight phantoms provided mean distortion measurements as well as additional imaging parameters (e.g., signal‐to‐noise ratio, uniformity, resolution). The Sun Nuclear Phantom exhibited higher overall distortion values. Conclusion: All four phantoms successfully measured distortion at multiple gantry angles on a 0.35 T MR‐Linac. The QUASAR MRID 3D Phantom uniquely differentiated B 0 from gradient distortions but required an offset adjustment. The MagPhan and QUASAR Insight phantoms offered comprehensive imaging metrics, while the Sun Nuclear Phantom exhibited relatively higher distortions.
- Open Access
- 15 August 2025
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 26 (8) , e70202
A novel Cherenkov radiation removal method for plastic scintillator detectors in a 0.35 T MR‐Linac
Purpose: This study evaluates methods for removing Cherenkov radiation (CR) from plastic scintillation detectors (PSDs), focusing on constraints specific to a 0.35 T MR‐Linac system.Methods: Five CR‐removal methods were examined: cross calibration, fiber alone, multiloop, collimator rotation, and couch rotation. The first three (cross calibration, fiber alone, and multiloop) were tested on a 0.35 T MR‐Linac (ViewRay Inc., USA) using the BluePhysics PSD (Blue Physics LLC, USA). These methods do not require collimator or couch rotation. The remaining two methods (collimator rotation and couch rotation) were tested on a Varian TrueBeam (Varian Medical Systems, USA) for comparison. Measurements were performed under various setup configurations, and Cherenkov radiation extraction (CRE) values were calculated to determine each method's effectiveness.Results: The multiloop approach yielded a CRE of 0.7288, making it the most practical and robust for MR‐Linac constraints because it requires neither collimator nor couch rotation. The cross calibration and fiber alone methods produced CRE values of 0.7318 and 0.7569, respectively. Collimator rotation gave 0.7255, comparable to multiloop. In contrast, couch rotation resulted in 0.7489 but exhibited more variability, suggesting lower reliability.Conclusion: The multiloop method emerged as the most practical and robust technique for CR removal in 0.35 T MR‐Linac systems. Its simplicity and compatibility with MR‐Linac design constraints make it a highly effective approach for CR removal in PSD‐based radiotherapy applications.
- 15 August 2025
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 26 (8) , e70202
Open AccessA novel Cherenkov radiation removal method for plastic scintillator detectors in a 0.35 T MR‐Linac
Purpose: This study evaluates methods for removing Cherenkov radiation (CR) from plastic scintillation detectors (PSDs), focusing on constraints specific to a 0.35 T MR‐Linac system.Methods: Five CR‐removal methods were examined: cross calibration, fiber alone, multiloop, collimator rotation, and couch rotation. The first three (cross calibration, fiber alone, and multiloop) were tested on a 0.35 T MR‐Linac (ViewRay Inc., USA) using the BluePhysics PSD (Blue Physics LLC, USA). These methods do not require collimator or couch rotation. The remaining two methods (collimator rotation and couch rotation) were tested on a Varian TrueBeam (Varian Medical Systems, USA) for comparison. Measurements were performed under various setup configurations, and Cherenkov radiation extraction (CRE) values were calculated to determine each method's effectiveness.Results: The multiloop approach yielded a CRE of 0.7288, making it the most practical and robust for MR‐Linac constraints because it requires neither collimator nor couch rotation. The cross calibration and fiber alone methods produced CRE values of 0.7318 and 0.7569, respectively. Collimator rotation gave 0.7255, comparable to multiloop. In contrast, couch rotation resulted in 0.7489 but exhibited more variability, suggesting lower reliability.Conclusion: The multiloop method emerged as the most practical and robust technique for CR removal in 0.35 T MR‐Linac systems. Its simplicity and compatibility with MR‐Linac design constraints make it a highly effective approach for CR removal in PSD‐based radiotherapy applications.
- Open Access
- 13 May 2025
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 26 (7) , e70116
Enhanced analysis of gating latency in 0.35T MR‐linac through innovative time synchronization of a motion phantom and plastic scintillation detector
Purpose: This study aims to evaluate how different gantry angles, breathing rates (BPM), cine image speeds, and tracking algorithms affect beam on/off latency and the subsequent impact on target dose for a 0.35T MR‐Linac with a 6 MV FFF beam. The investigation incorporates an image‐based MRI4D modus QA motion phantom (MQA) and a measurement‐based plastic scintillation detector (PSD). Methods: The MQA's target was customized with an insertion for a 1 mm PSD from BluePhysics. Both the PSD and the MQA were simultaneously synchronized to the Linac to capture latency signals. A plan was created in the ViewRay TPS to deliver dose to the target at three gantry angles (0°, 120°, and 240°). Each gantry angle was evaluated at three breathing rates (10, 12, and 15 BPM). The study also examined two imaging speeds (4 and 8 FPS) and four tracking algorithms. Results: Across all configurations at 4 FPS, the overall mean beam‐on latency was 0.339 ± 0.06 s from the PSD and 0.318 ± 0.06 s from the MQA, whereas at 8 FPS it was 0.630 ± 0.07 s (PSD) and 0.609 ± 0.07 s (MQA). Conversely, the overall mean beam‐off latency at 4 FPS was 0.153 ± 0.03 s (PSD) and 0.124 ± 0.03 s (MQA), while at 8 FPS it was 0.121 ± 0.06 s (PSD) and 0.205 ± 0.04 s (MQA). The overall mean difference between gating and non‐gating doses was an increase of 12.050 ± 9.2 cGy at 4 FPS and 14.044 ± 7.4 cGy at 8 FPS. Conclusion: This comprehensive study underscores the significant influence of gantry angle, breathing rate, cine imaging speed, and tracking algorithms on latency and dose delivery accuracy in a 0.35T MR‐Linac.
- 13 May 2025
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 26 (7) , e70116
Open AccessEnhanced analysis of gating latency in 0.35T MR‐linac through innovative time synchronization of a motion phantom and plastic scintillation detector
Purpose: This study aims to evaluate how different gantry angles, breathing rates (BPM), cine image speeds, and tracking algorithms affect beam on/off latency and the subsequent impact on target dose for a 0.35T MR‐Linac with a 6 MV FFF beam. The investigation incorporates an image‐based MRI4D modus QA motion phantom (MQA) and a measurement‐based plastic scintillation detector (PSD). Methods: The MQA's target was customized with an insertion for a 1 mm PSD from BluePhysics. Both the PSD and the MQA were simultaneously synchronized to the Linac to capture latency signals. A plan was created in the ViewRay TPS to deliver dose to the target at three gantry angles (0°, 120°, and 240°). Each gantry angle was evaluated at three breathing rates (10, 12, and 15 BPM). The study also examined two imaging speeds (4 and 8 FPS) and four tracking algorithms. Results: Across all configurations at 4 FPS, the overall mean beam‐on latency was 0.339 ± 0.06 s from the PSD and 0.318 ± 0.06 s from the MQA, whereas at 8 FPS it was 0.630 ± 0.07 s (PSD) and 0.609 ± 0.07 s (MQA). Conversely, the overall mean beam‐off latency at 4 FPS was 0.153 ± 0.03 s (PSD) and 0.124 ± 0.03 s (MQA), while at 8 FPS it was 0.121 ± 0.06 s (PSD) and 0.205 ± 0.04 s (MQA). The overall mean difference between gating and non‐gating doses was an increase of 12.050 ± 9.2 cGy at 4 FPS and 14.044 ± 7.4 cGy at 8 FPS. Conclusion: This comprehensive study underscores the significant influence of gantry angle, breathing rate, cine imaging speed, and tracking algorithms on latency and dose delivery accuracy in a 0.35T MR‐Linac.
- Open Access
- 19 March 2025
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 26 (4) , e70051
A systematic review of electron FLASH dosimetry and beam control mechanisms utilized with modified non‐clinical LINACs
Background: FLASH has been shown to spare normal tissue toxicity while maintaining tumor control. However, existing irradiation platforms and dosimetry are not compatible. Consequently, an abundance of FLASH delivery devices and new dosimetry across all modalities has been created. Many review articles concluded that dosimetry is modality‐dependent. Focusing on electrons, researchers have modified clinical LINACs to enable FLASH dose rates. Modified LINACs caused the development of unique control systems that have yet to be characterized. Improvement could be made when considering the organization of reviews.Purpose: To systematically perform a literature survey on electron FLASH dosimetry and beam control mechanisms with modified LINACs, detail where articles originated, and organize the results.Methods: A literature survey was performed from two websites using specified keywords and sifted results to find articles that fit the criteria. The results were organized in tables and summaries effectively by matching up dosimeters with their measurement goal, referring to their specific models, outlining the irradiation conditions they were tested in, and detailing their calibration procedure. Furthermore, included was the unique topic of control mechanisms.Results: Twenty‐eight matches were found. Various dosimeters were examined to measure absorbed dose, beam characteristics (BC), dose per pulse (DPP), and pulse counting (PC). Specific detectors and the irradiation conditions are organized and presented in a table. Each model's pros and cons are presented in another table for further consideration. A third table is provided to detail beam control methods.Conclusions: Dosimetry is majorly film‐based for absorbed dose and beam characteristic measurements. Many candidates for dosimeters for the use of DPP and PC have been tested, but they have yet to be tested without limitations. Beam control mechanisms primarily consist of unacceptable delivery errors. Many suggestions for improvement were given, mainly consisting of finding new dosimeters and modulating the dose DPP.
- 19 March 2025
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 26 (4) , e70051
Open AccessA systematic review of electron FLASH dosimetry and beam control mechanisms utilized with modified non‐clinical LINACs
Background: FLASH has been shown to spare normal tissue toxicity while maintaining tumor control. However, existing irradiation platforms and dosimetry are not compatible. Consequently, an abundance of FLASH delivery devices and new dosimetry across all modalities has been created. Many review articles concluded that dosimetry is modality‐dependent. Focusing on electrons, researchers have modified clinical LINACs to enable FLASH dose rates. Modified LINACs caused the development of unique control systems that have yet to be characterized. Improvement could be made when considering the organization of reviews.Purpose: To systematically perform a literature survey on electron FLASH dosimetry and beam control mechanisms with modified LINACs, detail where articles originated, and organize the results.Methods: A literature survey was performed from two websites using specified keywords and sifted results to find articles that fit the criteria. The results were organized in tables and summaries effectively by matching up dosimeters with their measurement goal, referring to their specific models, outlining the irradiation conditions they were tested in, and detailing their calibration procedure. Furthermore, included was the unique topic of control mechanisms.Results: Twenty‐eight matches were found. Various dosimeters were examined to measure absorbed dose, beam characteristics (BC), dose per pulse (DPP), and pulse counting (PC). Specific detectors and the irradiation conditions are organized and presented in a table. Each model's pros and cons are presented in another table for further consideration. A third table is provided to detail beam control methods.Conclusions: Dosimetry is majorly film‐based for absorbed dose and beam characteristic measurements. Many candidates for dosimeters for the use of DPP and PC have been tested, but they have yet to be tested without limitations. Beam control mechanisms primarily consist of unacceptable delivery errors. Many suggestions for improvement were given, mainly consisting of finding new dosimeters and modulating the dose DPP.
- Open Access
The Effect of Pacemakers and Defibrillators on Distortion in 2 Magnetic Resonance Imaging (MRI) Sequences Commonly Used in Radiation Oncology Practice—3D True Fast Imaging with Steady State Precession (TrueFISP) at 0.35T MR-Linear Accelerator (LINAC) and 3D T1 at 3T MR Simulator
Background: We aimed to measure the pacemaker- and defibrillator-induced distortion at 0.35T and 3.0T magnetic fields. Methods: The pacemaker/defibrillator was placed at the top center of a water-filled/MagPhan phantom, followed by a T1 scan at 3T and a TrueFISP scan at 0.35T. The extent of distortion (i.e., the distance from the device to the furthest signal loss/void/rings) in the water-filled phantom was measured in MIM. For geometrical distortion (i.e., dislocation of geometrical structures), the spheres in the MagPhan phantom were contoured and their distortion was calculated based on their manufacturing coordinate positions. Results: The maximum extent of distortion caused by the defibrillator was 18.8 cm at 0.35T and 5.8 cm at 3.0T. Similarly, the maximum extent of distortion caused by the pacemaker was 9.28 cm at 0.35T and 2.8 cm at 3.0T. Geometrical distortion measurements using the MagPhan phantom showed that the maximum distortion caused by the defibrillator was 12.8 mm at 0.35T and 13.2 mm at 3.0T. Likewise, the maximum distortion caused by the pacemaker was 8.7 mm at 0.35T and 6.0 mm at 3.0T. Conclusions: Defibrillators cause larger distortions/signal voids than pacemakers, and require careful consideration when performing MRI-based treatment planning. To minimize distortion, sequences with lower sensitivity to magnetic field inhomogeneity should be used.
Open AccessThe Effect of Pacemakers and Defibrillators on Distortion in 2 Magnetic Resonance Imaging (MRI) Sequences Commonly Used in Radiation Oncology Practice—3D True Fast Imaging with Steady State Precession (TrueFISP) at 0.35T MR-Linear Accelerator (LINAC) and 3D T1 at 3T MR Simulator
Background: We aimed to measure the pacemaker- and defibrillator-induced distortion at 0.35T and 3.0T magnetic fields. Methods: The pacemaker/defibrillator was placed at the top center of a water-filled/MagPhan phantom, followed by a T1 scan at 3T and a TrueFISP scan at 0.35T. The extent of distortion (i.e., the distance from the device to the furthest signal loss/void/rings) in the water-filled phantom was measured in MIM. For geometrical distortion (i.e., dislocation of geometrical structures), the spheres in the MagPhan phantom were contoured and their distortion was calculated based on their manufacturing coordinate positions. Results: The maximum extent of distortion caused by the defibrillator was 18.8 cm at 0.35T and 5.8 cm at 3.0T. Similarly, the maximum extent of distortion caused by the pacemaker was 9.28 cm at 0.35T and 2.8 cm at 3.0T. Geometrical distortion measurements using the MagPhan phantom showed that the maximum distortion caused by the defibrillator was 12.8 mm at 0.35T and 13.2 mm at 3.0T. Likewise, the maximum distortion caused by the pacemaker was 8.7 mm at 0.35T and 6.0 mm at 3.0T. Conclusions: Defibrillators cause larger distortions/signal voids than pacemakers, and require careful consideration when performing MRI-based treatment planning. To minimize distortion, sequences with lower sensitivity to magnetic field inhomogeneity should be used.