Mateb Al Khalifa
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Mateb Al Khalifa has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Siyong Kim
Department of Radiation Oncology Virginia Commonwealth University Richmond Virginia USA
5 shared publications - Haya Aljuaid
Department of Radiation Oncology Virginia Commonwealth University Richmond Virginia USA
4 shared publications Tianjun Ma
Department of Radiation Oncology Virginia Commonwealth University Richmond Virginia USA
4 shared publications- William Youngjae Song
Department of Radiation Oncology Virginia Commonwealth University Richmond Virginia USA
4 shared publications - Alireza Omidi
Department of Radiation Oncology, Virginia Commonwealth University Health System, Richmond, VA 23219, USA
1 shared publication Božidar Casar
Department of Dosimetry and Quality of Radiological Procedures Institute of Oncology Ljubljana Ljubljana Slovenia
1 shared publication
Latest Publications
- Open Access
- 14 February 2026
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 27 (2) , e70488
Acceptance testing of a 0.35 T MR‐Linac: procedures, QA baseline, and system limitations
Purpose: This study describes and evaluates the acceptance procedure for a ViewRay (VR) MRIdian 0.35T MR‐Linac, emphasizing key challenges, limitations, and recommendations to enhance clinical performance and accuracy. Methods: A comprehensive acceptance test was conducted at a single institution, following the manufacturer's protocols and aligned with established acceptance guidelines. Specific tools and phantoms were used to assess three primary components: mechanical, dosimetric, and Magnetic Resonance Imaging (MRI). Results: Overall, the test outcomes satisfied the manufacturer's specifications. However, certain issues were identified: high couch attenuation at specific gantry angles (leading to their exclusion from treatment), variations in magnetic field homogeneity at different gantry angles, and discrepancies between TPS calculations and measurements for field output factors smaller than 0.83 cm × 0.83 cm. Conclusion: This work provides a detailed account of the acceptance testing procedure and establishes a QA baseline for 0.35T MR‐Linac systems. In doing so, it also identifies key system limitations, such as couch attenuation, magnetic field inhomogeneity, and small‐field output discrepancies, underscoring the need for careful gantry angle selection, field homogeneity optimization, and meticulous validation of very small fields.
- 14 February 2026
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 27 (2) , e70488
Open AccessAcceptance testing of a 0.35 T MR‐Linac: procedures, QA baseline, and system limitations
Purpose: This study describes and evaluates the acceptance procedure for a ViewRay (VR) MRIdian 0.35T MR‐Linac, emphasizing key challenges, limitations, and recommendations to enhance clinical performance and accuracy. Methods: A comprehensive acceptance test was conducted at a single institution, following the manufacturer's protocols and aligned with established acceptance guidelines. Specific tools and phantoms were used to assess three primary components: mechanical, dosimetric, and Magnetic Resonance Imaging (MRI). Results: Overall, the test outcomes satisfied the manufacturer's specifications. However, certain issues were identified: high couch attenuation at specific gantry angles (leading to their exclusion from treatment), variations in magnetic field homogeneity at different gantry angles, and discrepancies between TPS calculations and measurements for field output factors smaller than 0.83 cm × 0.83 cm. Conclusion: This work provides a detailed account of the acceptance testing procedure and establishes a QA baseline for 0.35T MR‐Linac systems. In doing so, it also identifies key system limitations, such as couch attenuation, magnetic field inhomogeneity, and small‐field output discrepancies, underscoring the need for careful gantry angle selection, field homogeneity optimization, and meticulous validation of very small fields.
- Open Access
- 10 February 2026
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 27 (2) , e70500
Evaluating equivalent square field size definitions for rectangular small fields
Background: In the IAEA TRS‐483 Code of Practice (CoP), rectangular small field sizes are approximated to equivalent square small fields using the definition proposed by Cranmer‐Sargison et al. However, the CoP estimates the uncertainties associated with this formula only for rectangular fields with dimensions within the range . Purpose: The objective of the present study was to compare the accuracy of the Cranmer‐Sargison definition with other formulas for equivalent square small fields in the context of measuring field output factors (FOFs) for rectangular small fields, both within and outside the range covered by the CoP. Methods: Measurements were conducted using Gafchromic EBT4 radiochromic films. The models compared included Cranmer‐Sargison, Sterling, Superellipse, Sterling‐Partial Superellipse, Sterling‐Superellipse, Vadash and Bjärngard, and Fogliata. The most accurate definition of equivalent square field size was identified as the one yielding the lowest discrepancy between measured and analytical values, with the log‐likelihood of the measurements selected as the metric. Analytical values were derived using the function introduced by Sauer and Wilbert, which relates FOFs to equivalent square field sizes. Results: The best results were achieved with the Fogliata model, followed in terms of accuracy by the Sterling‐Partial Superellipse model. The Sterling‐Superellipse and Vadash and Bjärngard models came next. It should be noted that the Sterling‐Partial Superellipse and Sterling‐Superellipse models rely solely on the geometric shape of the irradiation field size, whereas the Fogliata and Vadash and Bjärngard models incorporate a fitting parameter. The Sterling definition, while less accurate than these models, improved upon the Cranmer‐Sargison definition and retained computational simplicity. Finally, the Cranmer‐Sargison and Superellipse models exhibited the largest discrepancies. Conclusions: This study identified several definitions of equivalent square small field size that could refine the IAEA TRS‐483 CoP by improving the accuracy of field output correction factors for rectangular small fields. Among these definitions, the Fogliata model obtained the best results.
- 10 February 2026
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 27 (2) , e70500
Open AccessEvaluating equivalent square field size definitions for rectangular small fields
Background: In the IAEA TRS‐483 Code of Practice (CoP), rectangular small field sizes are approximated to equivalent square small fields using the definition proposed by Cranmer‐Sargison et al. However, the CoP estimates the uncertainties associated with this formula only for rectangular fields with dimensions within the range . Purpose: The objective of the present study was to compare the accuracy of the Cranmer‐Sargison definition with other formulas for equivalent square small fields in the context of measuring field output factors (FOFs) for rectangular small fields, both within and outside the range covered by the CoP. Methods: Measurements were conducted using Gafchromic EBT4 radiochromic films. The models compared included Cranmer‐Sargison, Sterling, Superellipse, Sterling‐Partial Superellipse, Sterling‐Superellipse, Vadash and Bjärngard, and Fogliata. The most accurate definition of equivalent square field size was identified as the one yielding the lowest discrepancy between measured and analytical values, with the log‐likelihood of the measurements selected as the metric. Analytical values were derived using the function introduced by Sauer and Wilbert, which relates FOFs to equivalent square field sizes. Results: The best results were achieved with the Fogliata model, followed in terms of accuracy by the Sterling‐Partial Superellipse model. The Sterling‐Superellipse and Vadash and Bjärngard models came next. It should be noted that the Sterling‐Partial Superellipse and Sterling‐Superellipse models rely solely on the geometric shape of the irradiation field size, whereas the Fogliata and Vadash and Bjärngard models incorporate a fitting parameter. The Sterling definition, while less accurate than these models, improved upon the Cranmer‐Sargison definition and retained computational simplicity. Finally, the Cranmer‐Sargison and Superellipse models exhibited the largest discrepancies. Conclusions: This study identified several definitions of equivalent square small field size that could refine the IAEA TRS‐483 CoP by improving the accuracy of field output correction factors for rectangular small fields. Among these definitions, the Fogliata model obtained the best results.
- Open Access
- 9 September 2025
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 26 (9) , e70247
Clinical comparison of four commercial MRI phantoms on a 0.35T MR‐linac using a standard clinical TRUFI sequence at a single institution
Purpose: Real‑time magnetic resonance–guided radiation therapy (MRgRT) integrates MRI with a linear accelerator (Linac) for gating and adaptive radiotherapy, which requires robust image‑quality assurance over a large field of view (FOV). Specialized phantoms capable of accommodating this extensive FOV are therefore essential. This study compares the performance of four commercial MRI phantoms on a 0.35 T MR‑Linac. Methods: Four phantoms: the IBA QUASAR Insight Phantom, the IBA QUASAR MRID 3D Geometric Distortion Phantom, the MagPhan Phantom, and the Sun Nuclear Large Field MRI Distortion Phantom, were evaluated on a 0.35 T MR‐Linac using the TRUFI clinical sequence. Mean distortions were measured at gantry angles from 0° to 360° in 30° increments. Clinical imaging parameters (signal‐to‐noise ratio, uniformity, resolution via modulation transfer function, laser alignment, and twist) were also assessed where applicable. Results: The QUASAR MRID 3D Phantom enabled separate quantification of B 0 and gradient‐induced distortions but showed a notable vertical offset, which did not affect comparisons with other phantoms. Both the MagPhan and QUASAR Insight phantoms provided mean distortion measurements as well as additional imaging parameters (e.g., signal‐to‐noise ratio, uniformity, resolution). The Sun Nuclear Phantom exhibited higher overall distortion values. Conclusion: All four phantoms successfully measured distortion at multiple gantry angles on a 0.35 T MR‐Linac. The QUASAR MRID 3D Phantom uniquely differentiated B 0 from gradient distortions but required an offset adjustment. The MagPhan and QUASAR Insight phantoms offered comprehensive imaging metrics, while the Sun Nuclear Phantom exhibited relatively higher distortions.
- 9 September 2025
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 26 (9) , e70247
Open AccessClinical comparison of four commercial MRI phantoms on a 0.35T MR‐linac using a standard clinical TRUFI sequence at a single institution
Purpose: Real‑time magnetic resonance–guided radiation therapy (MRgRT) integrates MRI with a linear accelerator (Linac) for gating and adaptive radiotherapy, which requires robust image‑quality assurance over a large field of view (FOV). Specialized phantoms capable of accommodating this extensive FOV are therefore essential. This study compares the performance of four commercial MRI phantoms on a 0.35 T MR‑Linac. Methods: Four phantoms: the IBA QUASAR Insight Phantom, the IBA QUASAR MRID 3D Geometric Distortion Phantom, the MagPhan Phantom, and the Sun Nuclear Large Field MRI Distortion Phantom, were evaluated on a 0.35 T MR‐Linac using the TRUFI clinical sequence. Mean distortions were measured at gantry angles from 0° to 360° in 30° increments. Clinical imaging parameters (signal‐to‐noise ratio, uniformity, resolution via modulation transfer function, laser alignment, and twist) were also assessed where applicable. Results: The QUASAR MRID 3D Phantom enabled separate quantification of B 0 and gradient‐induced distortions but showed a notable vertical offset, which did not affect comparisons with other phantoms. Both the MagPhan and QUASAR Insight phantoms provided mean distortion measurements as well as additional imaging parameters (e.g., signal‐to‐noise ratio, uniformity, resolution). The Sun Nuclear Phantom exhibited higher overall distortion values. Conclusion: All four phantoms successfully measured distortion at multiple gantry angles on a 0.35 T MR‐Linac. The QUASAR MRID 3D Phantom uniquely differentiated B 0 from gradient distortions but required an offset adjustment. The MagPhan and QUASAR Insight phantoms offered comprehensive imaging metrics, while the Sun Nuclear Phantom exhibited relatively higher distortions.
- Open Access
- 15 August 2025
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 26 (8) , e70202
A novel Cherenkov radiation removal method for plastic scintillator detectors in a 0.35 T MR‐Linac
Purpose: This study evaluates methods for removing Cherenkov radiation (CR) from plastic scintillation detectors (PSDs), focusing on constraints specific to a 0.35 T MR‐Linac system.Methods: Five CR‐removal methods were examined: cross calibration, fiber alone, multiloop, collimator rotation, and couch rotation. The first three (cross calibration, fiber alone, and multiloop) were tested on a 0.35 T MR‐Linac (ViewRay Inc., USA) using the BluePhysics PSD (Blue Physics LLC, USA). These methods do not require collimator or couch rotation. The remaining two methods (collimator rotation and couch rotation) were tested on a Varian TrueBeam (Varian Medical Systems, USA) for comparison. Measurements were performed under various setup configurations, and Cherenkov radiation extraction (CRE) values were calculated to determine each method's effectiveness.Results: The multiloop approach yielded a CRE of 0.7288, making it the most practical and robust for MR‐Linac constraints because it requires neither collimator nor couch rotation. The cross calibration and fiber alone methods produced CRE values of 0.7318 and 0.7569, respectively. Collimator rotation gave 0.7255, comparable to multiloop. In contrast, couch rotation resulted in 0.7489 but exhibited more variability, suggesting lower reliability.Conclusion: The multiloop method emerged as the most practical and robust technique for CR removal in 0.35 T MR‐Linac systems. Its simplicity and compatibility with MR‐Linac design constraints make it a highly effective approach for CR removal in PSD‐based radiotherapy applications.
- 15 August 2025
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 26 (8) , e70202
Open AccessA novel Cherenkov radiation removal method for plastic scintillator detectors in a 0.35 T MR‐Linac
Purpose: This study evaluates methods for removing Cherenkov radiation (CR) from plastic scintillation detectors (PSDs), focusing on constraints specific to a 0.35 T MR‐Linac system.Methods: Five CR‐removal methods were examined: cross calibration, fiber alone, multiloop, collimator rotation, and couch rotation. The first three (cross calibration, fiber alone, and multiloop) were tested on a 0.35 T MR‐Linac (ViewRay Inc., USA) using the BluePhysics PSD (Blue Physics LLC, USA). These methods do not require collimator or couch rotation. The remaining two methods (collimator rotation and couch rotation) were tested on a Varian TrueBeam (Varian Medical Systems, USA) for comparison. Measurements were performed under various setup configurations, and Cherenkov radiation extraction (CRE) values were calculated to determine each method's effectiveness.Results: The multiloop approach yielded a CRE of 0.7288, making it the most practical and robust for MR‐Linac constraints because it requires neither collimator nor couch rotation. The cross calibration and fiber alone methods produced CRE values of 0.7318 and 0.7569, respectively. Collimator rotation gave 0.7255, comparable to multiloop. In contrast, couch rotation resulted in 0.7489 but exhibited more variability, suggesting lower reliability.Conclusion: The multiloop method emerged as the most practical and robust technique for CR removal in 0.35 T MR‐Linac systems. Its simplicity and compatibility with MR‐Linac design constraints make it a highly effective approach for CR removal in PSD‐based radiotherapy applications.
- Open Access
- 13 May 2025
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 26 (7) , e70116
Enhanced analysis of gating latency in 0.35T MR‐linac through innovative time synchronization of a motion phantom and plastic scintillation detector
Purpose: This study aims to evaluate how different gantry angles, breathing rates (BPM), cine image speeds, and tracking algorithms affect beam on/off latency and the subsequent impact on target dose for a 0.35T MR‐Linac with a 6 MV FFF beam. The investigation incorporates an image‐based MRI4D modus QA motion phantom (MQA) and a measurement‐based plastic scintillation detector (PSD). Methods: The MQA's target was customized with an insertion for a 1 mm PSD from BluePhysics. Both the PSD and the MQA were simultaneously synchronized to the Linac to capture latency signals. A plan was created in the ViewRay TPS to deliver dose to the target at three gantry angles (0°, 120°, and 240°). Each gantry angle was evaluated at three breathing rates (10, 12, and 15 BPM). The study also examined two imaging speeds (4 and 8 FPS) and four tracking algorithms. Results: Across all configurations at 4 FPS, the overall mean beam‐on latency was 0.339 ± 0.06 s from the PSD and 0.318 ± 0.06 s from the MQA, whereas at 8 FPS it was 0.630 ± 0.07 s (PSD) and 0.609 ± 0.07 s (MQA). Conversely, the overall mean beam‐off latency at 4 FPS was 0.153 ± 0.03 s (PSD) and 0.124 ± 0.03 s (MQA), while at 8 FPS it was 0.121 ± 0.06 s (PSD) and 0.205 ± 0.04 s (MQA). The overall mean difference between gating and non‐gating doses was an increase of 12.050 ± 9.2 cGy at 4 FPS and 14.044 ± 7.4 cGy at 8 FPS. Conclusion: This comprehensive study underscores the significant influence of gantry angle, breathing rate, cine imaging speed, and tracking algorithms on latency and dose delivery accuracy in a 0.35T MR‐Linac.
- 13 May 2025
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 26 (7) , e70116
Open AccessEnhanced analysis of gating latency in 0.35T MR‐linac through innovative time synchronization of a motion phantom and plastic scintillation detector
Purpose: This study aims to evaluate how different gantry angles, breathing rates (BPM), cine image speeds, and tracking algorithms affect beam on/off latency and the subsequent impact on target dose for a 0.35T MR‐Linac with a 6 MV FFF beam. The investigation incorporates an image‐based MRI4D modus QA motion phantom (MQA) and a measurement‐based plastic scintillation detector (PSD). Methods: The MQA's target was customized with an insertion for a 1 mm PSD from BluePhysics. Both the PSD and the MQA were simultaneously synchronized to the Linac to capture latency signals. A plan was created in the ViewRay TPS to deliver dose to the target at three gantry angles (0°, 120°, and 240°). Each gantry angle was evaluated at three breathing rates (10, 12, and 15 BPM). The study also examined two imaging speeds (4 and 8 FPS) and four tracking algorithms. Results: Across all configurations at 4 FPS, the overall mean beam‐on latency was 0.339 ± 0.06 s from the PSD and 0.318 ± 0.06 s from the MQA, whereas at 8 FPS it was 0.630 ± 0.07 s (PSD) and 0.609 ± 0.07 s (MQA). Conversely, the overall mean beam‐off latency at 4 FPS was 0.153 ± 0.03 s (PSD) and 0.124 ± 0.03 s (MQA), while at 8 FPS it was 0.121 ± 0.06 s (PSD) and 0.205 ± 0.04 s (MQA). The overall mean difference between gating and non‐gating doses was an increase of 12.050 ± 9.2 cGy at 4 FPS and 14.044 ± 7.4 cGy at 8 FPS. Conclusion: This comprehensive study underscores the significant influence of gantry angle, breathing rate, cine imaging speed, and tracking algorithms on latency and dose delivery accuracy in a 0.35T MR‐Linac.
- Open Access
The Effect of Pacemakers and Defibrillators on Distortion in 2 Magnetic Resonance Imaging (MRI) Sequences Commonly Used in Radiation Oncology Practice—3D True Fast Imaging with Steady State Precession (TrueFISP) at 0.35T MR-Linear Accelerator (LINAC) and 3D T1 at 3T MR Simulator
Background: We aimed to measure the pacemaker- and defibrillator-induced distortion at 0.35T and 3.0T magnetic fields. Methods: The pacemaker/defibrillator was placed at the top center of a water-filled/MagPhan phantom, followed by a T1 scan at 3T and a TrueFISP scan at 0.35T. The extent of distortion (i.e., the distance from the device to the furthest signal loss/void/rings) in the water-filled phantom was measured in MIM. For geometrical distortion (i.e., dislocation of geometrical structures), the spheres in the MagPhan phantom were contoured and their distortion was calculated based on their manufacturing coordinate positions. Results: The maximum extent of distortion caused by the defibrillator was 18.8 cm at 0.35T and 5.8 cm at 3.0T. Similarly, the maximum extent of distortion caused by the pacemaker was 9.28 cm at 0.35T and 2.8 cm at 3.0T. Geometrical distortion measurements using the MagPhan phantom showed that the maximum distortion caused by the defibrillator was 12.8 mm at 0.35T and 13.2 mm at 3.0T. Likewise, the maximum distortion caused by the pacemaker was 8.7 mm at 0.35T and 6.0 mm at 3.0T. Conclusions: Defibrillators cause larger distortions/signal voids than pacemakers, and require careful consideration when performing MRI-based treatment planning. To minimize distortion, sequences with lower sensitivity to magnetic field inhomogeneity should be used.
Open AccessThe Effect of Pacemakers and Defibrillators on Distortion in 2 Magnetic Resonance Imaging (MRI) Sequences Commonly Used in Radiation Oncology Practice—3D True Fast Imaging with Steady State Precession (TrueFISP) at 0.35T MR-Linear Accelerator (LINAC) and 3D T1 at 3T MR Simulator
Background: We aimed to measure the pacemaker- and defibrillator-induced distortion at 0.35T and 3.0T magnetic fields. Methods: The pacemaker/defibrillator was placed at the top center of a water-filled/MagPhan phantom, followed by a T1 scan at 3T and a TrueFISP scan at 0.35T. The extent of distortion (i.e., the distance from the device to the furthest signal loss/void/rings) in the water-filled phantom was measured in MIM. For geometrical distortion (i.e., dislocation of geometrical structures), the spheres in the MagPhan phantom were contoured and their distortion was calculated based on their manufacturing coordinate positions. Results: The maximum extent of distortion caused by the defibrillator was 18.8 cm at 0.35T and 5.8 cm at 3.0T. Similarly, the maximum extent of distortion caused by the pacemaker was 9.28 cm at 0.35T and 2.8 cm at 3.0T. Geometrical distortion measurements using the MagPhan phantom showed that the maximum distortion caused by the defibrillator was 12.8 mm at 0.35T and 13.2 mm at 3.0T. Likewise, the maximum distortion caused by the pacemaker was 8.7 mm at 0.35T and 6.0 mm at 3.0T. Conclusions: Defibrillators cause larger distortions/signal voids than pacemakers, and require careful consideration when performing MRI-based treatment planning. To minimize distortion, sequences with lower sensitivity to magnetic field inhomogeneity should be used.