Luca Novello
Research Subjects
Luca Novello has a total of 40 co-authors. Here are the top co-authors by number of shared publications:
- Kazuya Hamada
National Institutes for Quantum Science and Technology, Naka, Japan
4 shared publications - Haruyuki Murakami
National Institutes for Quantum Science and Technology, Naka, Japan
3 shared publications - Louis Zani
Fusion for Energy, Garching, Germany
3 shared publications - Benoit Lacroix
CEA-IRFM, St-Paul Lez Durance, France
2 shared publications - Katsuhiro Shimada
National Institutes for Quantum and Radiological Science and Technology, Naka, Ibaraki, Japan
2 shared publications - Manfred Wanner
Fusion for Energy, Garching, Germany
2 shared publications
Latest Publications
- 29 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 36 (5) , 1-4
Improvement of the Quench Detection System for the PF Coils of JT-60SA
The JT-60SA superconducting coil system comprises 6 Equilibrium Field coils, 4 Central Solenoid modules, and 18 Toroidal Field coils. Detecting a quench correctly in superconducting coils is essential to avoid damage of the coil. During the last integrated commissioning test, spike-shaped voltage fluctuations were observed on the EF and CS quench detection (QD) voltages. The voltage fluctuations occurred when the currents in the EF and CS coils rapidly changed. Following a circuit analysis of the EF coils, it was found that the spike voltage originated at the input of the QD differential amplifier from a slight mismatch of the time constants of the resistance-capacitance (RC) noise filter circuit. The RC filter circuit had to be adjusted precisely to achieve the same time constant between the winding and the pickup coil. The reduction of spike noise was experimentally confirmed by adjusting the variable capacitor or resistor in the filter circuit.
- 29 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 36 (5) , 1-4
Improvement of the Quench Detection System for the PF Coils of JT-60SA
The JT-60SA superconducting coil system comprises 6 Equilibrium Field coils, 4 Central Solenoid modules, and 18 Toroidal Field coils. Detecting a quench correctly in superconducting coils is essential to avoid damage of the coil. During the last integrated commissioning test, spike-shaped voltage fluctuations were observed on the EF and CS quench detection (QD) voltages. The voltage fluctuations occurred when the currents in the EF and CS coils rapidly changed. Following a circuit analysis of the EF coils, it was found that the spike voltage originated at the input of the QD differential amplifier from a slight mismatch of the time constants of the resistance-capacitance (RC) noise filter circuit. The RC filter circuit had to be adjusted precisely to achieve the same time constant between the winding and the pickup coil. The reduction of spike noise was experimentally confirmed by adjusting the variable capacitor or resistor in the filter circuit.
- 21 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 36 (3) , 1-5
JT-60SA Central Solenoid Conductor Hotspot Risk Analysis for High Voltage Protection
The upgrade to JT-60SA tokamak was conducted within a Europe-Japan collaboration agreement including superconducting magnets implementation. In 2021, an arcing issue on a coil led to an overall magnet insulation reinforcement against high voltage. The Central Solenoid (CS), less accessible for repair, deserving specific attention versus voltage exposure, a risk mitigation was considered to address fast discharge event, which results in the highest voltage application. Maximum voltage during discharge being proportional to the external dump resistance (RDUMP), it is aimed at decreasing this resistance by 30%, inducing a slower current decrease after a quench, therefore a higher Joule energy absorbed by conductor. This induces a higher temperature rise in the conductor, increasing the risk of thermo-mechanical degradation due to hotspot occurrence. A risk analysis is performed to better understand the impact on the conductor. A methodology is followed to define streamlined hotspot risk criteria, backed by rationale and references to support the establishment of those methodological elements. Thermo-hydraulic simulations on the CS magnet, that were extensively produced, are analyzed to ensure that even after dump resistance modification, the hotspot safety limits are still respected. For this, a reference case and associated parametric studies were explored using THEA code. Finally, a positive recommendation is issued to validate and implement the JT-60SA project team decision to decrease the CS magnet RDUMP. Further perspectives are also evaluated.
- 21 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 36 (3) , 1-5
JT-60SA Central Solenoid Conductor Hotspot Risk Analysis for High Voltage Protection
The upgrade to JT-60SA tokamak was conducted within a Europe-Japan collaboration agreement including superconducting magnets implementation. In 2021, an arcing issue on a coil led to an overall magnet insulation reinforcement against high voltage. The Central Solenoid (CS), less accessible for repair, deserving specific attention versus voltage exposure, a risk mitigation was considered to address fast discharge event, which results in the highest voltage application. Maximum voltage during discharge being proportional to the external dump resistance (RDUMP), it is aimed at decreasing this resistance by 30%, inducing a slower current decrease after a quench, therefore a higher Joule energy absorbed by conductor. This induces a higher temperature rise in the conductor, increasing the risk of thermo-mechanical degradation due to hotspot occurrence. A risk analysis is performed to better understand the impact on the conductor. A methodology is followed to define streamlined hotspot risk criteria, backed by rationale and references to support the establishment of those methodological elements. Thermo-hydraulic simulations on the CS magnet, that were extensively produced, are analyzed to ensure that even after dump resistance modification, the hotspot safety limits are still respected. For this, a reference case and associated parametric studies were explored using THEA code. Finally, a positive recommendation is issued to validate and implement the JT-60SA project team decision to decrease the CS magnet RDUMP. Further perspectives are also evaluated.
- 25 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 35 (5) , 1-5
Exploring Operation Limits of JT-60SA Cryomagnet Operation: Integrated Commissioning Database Use for Modeling Analysis
In the framework of international development on fusion devices, the tokamak JT-60SA was equipped with superconducting magnets within a Europe-Japan collaboration. After a first integrated commissioning (IC) in 2021, another IC was conducted in 2023 reaching magnet energization levels compliant with 1 MA-class plasmas. The Toroidal Field (TF) coil system was loaded at nominal current and the Poloidal Field (PF) at 50% of nominal current. In the 2023 IC various energization pulse patterns were applied on PF coils to gain experience on the magnets control and protection system in operation conditions. Some tailored current pulses were applied to learn about PF coils coupling parameters and protection system, which sensitivity was found to be improved. In this environment, we developed tools and methods to model and predict the magnets behaviour to possibly identify coils limits in operation conditions. First step is with thermo-hydraulic evaluation of PF coil temperature safety margin evaluation along their pulsed current patterns. Second step is a first order analysis of the TF quench detection system sensitivity, found higher than expected to PF transients, and the contribution to possible mitigation measures to avoid spurious false positive detections. Both steps were benchmarked against experimental data collected during 2023 IC to consolidate models prediction capacities. Foreseen applications aim at checking plasma scenarios repetability rate or avoiding pulsed coil current to generate apparent fault signal in absence of real risk (mostly quench). The tools and methods are described and their rationales explained, together with their intrinsic limits and room for improvement.
- 25 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 35 (5) , 1-5
Exploring Operation Limits of JT-60SA Cryomagnet Operation: Integrated Commissioning Database Use for Modeling Analysis
In the framework of international development on fusion devices, the tokamak JT-60SA was equipped with superconducting magnets within a Europe-Japan collaboration. After a first integrated commissioning (IC) in 2021, another IC was conducted in 2023 reaching magnet energization levels compliant with 1 MA-class plasmas. The Toroidal Field (TF) coil system was loaded at nominal current and the Poloidal Field (PF) at 50% of nominal current. In the 2023 IC various energization pulse patterns were applied on PF coils to gain experience on the magnets control and protection system in operation conditions. Some tailored current pulses were applied to learn about PF coils coupling parameters and protection system, which sensitivity was found to be improved. In this environment, we developed tools and methods to model and predict the magnets behaviour to possibly identify coils limits in operation conditions. First step is with thermo-hydraulic evaluation of PF coil temperature safety margin evaluation along their pulsed current patterns. Second step is a first order analysis of the TF quench detection system sensitivity, found higher than expected to PF transients, and the contribution to possible mitigation measures to avoid spurious false positive detections. Both steps were benchmarked against experimental data collected during 2023 IC to consolidate models prediction capacities. Foreseen applications aim at checking plasma scenarios repetability rate or avoiding pulsed coil current to generate apparent fault signal in absence of real risk (mostly quench). The tools and methods are described and their rationales explained, together with their intrinsic limits and room for improvement.
- 27 December 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 34 (5) , 1-5
Lessons Learned From EF1 Electrical Short Incident During JT-60SA Integrated Commissioning Test
The superconducting tokamak fusion test device, JT-60SA, was constructed as the Satellite Tokamak project in the Broader Approach Program between Japan and EU. During the JT-60SA integrated commissioning tests of the Nb-Ti equilibrium magnetic field coil EF1 high voltage (∼5 kV) test, the EF1 power supply current surged suddenly and was stopped by the overcurrent interlock of the power supply. At the same time, the vacuum in the cryostat deteriorated, and the pressure in the magnet cooling loops increased. After the system warmed up, visual inspection revealed that discharges occurred between ground and both positive and negative terminal joints of EF1. Several holes, melted by the electrical short and identified as the source of the helium leak into the cryostat, were found in the cylindrical metal part of the joint. The data recorded at the time of the event were analyzed with a conclusion that the discharge first occurred between the positive terminal joint and its support bracket at ground potential and immediately afterward between the neighboring negative terminal joint and its support bracket. These two arcs created a short-circuited loop through which the coil discharged for about 1.4 s. The energy during the short circuit is estimated to be about 60 kJ.
- 27 December 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 34 (5) , 1-5
Lessons Learned From EF1 Electrical Short Incident During JT-60SA Integrated Commissioning Test
The superconducting tokamak fusion test device, JT-60SA, was constructed as the Satellite Tokamak project in the Broader Approach Program between Japan and EU. During the JT-60SA integrated commissioning tests of the Nb-Ti equilibrium magnetic field coil EF1 high voltage (∼5 kV) test, the EF1 power supply current surged suddenly and was stopped by the overcurrent interlock of the power supply. At the same time, the vacuum in the cryostat deteriorated, and the pressure in the magnet cooling loops increased. After the system warmed up, visual inspection revealed that discharges occurred between ground and both positive and negative terminal joints of EF1. Several holes, melted by the electrical short and identified as the source of the helium leak into the cryostat, were found in the cylindrical metal part of the joint. The data recorded at the time of the event were analyzed with a conclusion that the discharge first occurred between the positive terminal joint and its support bracket at ground potential and immediately afterward between the neighboring negative terminal joint and its support bracket. These two arcs created a short-circuited loop through which the coil discharged for about 1.4 s. The energy during the short circuit is estimated to be about 60 kJ.
- 1 October 2015
- Published by Elsevier in Fusion Engineering and Design
- Vol. 98-99, 1122-1126
Overview of the new Magnet Power Supply Systems of JT-60SA procured by EU
- 1 October 2015
- Published by Elsevier in Fusion Engineering and Design
- Vol. 98-99, 1122-1126
Overview of the new Magnet Power Supply Systems of JT-60SA procured by EU