Shogo Koshiya
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Shogo Koshiya has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Masami Terauchi
Tohoku Center of Excellence for Microscopy (TCEM), Tohoku University , 2-1-1 Katahira, Aoba-ku , Sendai, Miyagi 980-8577
4 shared publications - Takanori Murano
SA Research and Development Department, SA Business Unit, JEOL Ltd , 3-1-2 Musashino , Akishima, Tokyo 196-8558
4 shared publications - Alexander Sergeevich Pirozhkov
Kansai Institute for Photon Science (KPSI), National Institutes for Quantum Science and Technology (QST), Kyoto, Japan
3 shared publications - Kiminori Kondo
Kansai Institute for Photon Science, National Institutes for Quantum Science and Technology (QST) 1 , 8-1-7 Umemidai, Kizugawa, Kyoto 619-0215
3 shared publications - Masato Koike
Department of Orthopaedics, Juntendo University Faculty of Medicine, Bunkyo-ku, Tokyo, Japan
3 shared publications T. Kakio
Device Department, Shimadzu Corporation 7 , Nakagyu-ku, Kyoto, Kyoto 604-8511
3 shared publications
Latest Publications
- 21 March 2026
- Published by Oxford University Press (OUP) in Microscopy
- Vol. 75 (5) , 371-376
Systematic study of chemical bonding states of lithium binary compounds from Li K-L emission spectra obtained by a VUV spectrometer mounted on a scanning electron microscope
The Li K-L emission spectra of lithium metal and its binary compounds (Li3N, Li2O, and LiF) were measured by using a soft X-ray emission spectrometer (SXES), which was equipped with a newly developed high-efficiency diffraction grating (JS35BC) and attached to an electron probe microanalyzer (EPMA). The new grating enables the observation of the entire intensity profile of both Li K-L and Mg L2,3-M emission spectra. The systematic energy shift of the Li K-L spectra to the lower energy side with an increasing electronegativity (or the ionization tendency) of elements of N, O, and F bonded with the Li atom was clearly detected. This shift was reproduced by theoretical calculations and was assigned mainly due to the change of the binding energy of the valence band of those materials. The main peak and its distinct shoulder structure observed in Li K-L spectrum of LiF were assigned as 2p dominated and 2 s + 2p mixed states, respectively, from the comparison with theoretical calculations.
- 21 March 2026
- Published by Oxford University Press (OUP) in Microscopy
- Vol. 75 (5) , 371-376
Systematic study of chemical bonding states of lithium binary compounds from Li K-L emission spectra obtained by a VUV spectrometer mounted on a scanning electron microscope
The Li K-L emission spectra of lithium metal and its binary compounds (Li3N, Li2O, and LiF) were measured by using a soft X-ray emission spectrometer (SXES), which was equipped with a newly developed high-efficiency diffraction grating (JS35BC) and attached to an electron probe microanalyzer (EPMA). The new grating enables the observation of the entire intensity profile of both Li K-L and Mg L2,3-M emission spectra. The systematic energy shift of the Li K-L spectra to the lower energy side with an increasing electronegativity (or the ionization tendency) of elements of N, O, and F bonded with the Li atom was clearly detected. This shift was reproduced by theoretical calculations and was assigned mainly due to the change of the binding energy of the valence band of those materials. The main peak and its distinct shoulder structure observed in Li K-L spectrum of LiF were assigned as 2p dominated and 2 s + 2p mixed states, respectively, from the comparison with theoretical calculations.
- 16 April 2025
- Published by Oxford University Press (OUP) in Microscopy
- Vol. 74 (6) , 432-436
High energy-resolution soft X-ray emission spectrometer using a back-thinned CMOS detector for chemical bonding state analysis
Improvement of a commercially available soft X-ray emission spectrometer was tested by introducing a fine-pixel-sized CMOS detector. The peak width of Mg Kα-emission was reduced to one-fourth of that obtained by the CCD detector presently used. Furthermore, the differences in the energy positions of satellite lines of Mg Kα- and also Kβ-emission profiles of Mg and MgO were observed. O K-emission profile of MgO exhibited a few structures reflecting the chemical bonding state. This spectrometer easily discriminated the intensity profiles of Fe Lα,β-emission reflecting the chemical bonding states of Fe atoms in Fe, FeO, Fe3O4 and Fe2O3.
- 16 April 2025
- Published by Oxford University Press (OUP) in Microscopy
- Vol. 74 (6) , 432-436
High energy-resolution soft X-ray emission spectrometer using a back-thinned CMOS detector for chemical bonding state analysis
Improvement of a commercially available soft X-ray emission spectrometer was tested by introducing a fine-pixel-sized CMOS detector. The peak width of Mg Kα-emission was reduced to one-fourth of that obtained by the CCD detector presently used. Furthermore, the differences in the energy positions of satellite lines of Mg Kα- and also Kβ-emission profiles of Mg and MgO were observed. O K-emission profile of MgO exhibited a few structures reflecting the chemical bonding state. This spectrometer easily discriminated the intensity profiles of Fe Lα,β-emission reflecting the chemical bonding states of Fe atoms in Fe, FeO, Fe3O4 and Fe2O3.
- 1 December 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (12)
Design of soft x-ray high diffraction efficiency and spectral flux Au/Ni bilayer coated laminar-type diffraction grating for objective soft x-ray flat-field spectrograph in a region of 250–550 eV
An objective soft x-ray flat-field spectrograph employing a laminar-type bilayer coated, varied-line-spacing, spherical grating was designed to improve the detection limit and sensitivity of soft x-ray flat-field spectrographs in a region of 250–550 eV. As a design criterion, spectral flux, SF, [Hatano et al., Appl. Opt. 60, 4993–4999 (2021)], which is proportional to the amount of optical flux incident onto a detector and correlated with detection sensitivity, was used to be maximized. To enhance reflectivity with the coating design, Au/Ni bilayer coating was investigated to optimize the incidence angle and thickness of the Ni layer. This is based on the consideration that, in an energy region of over 400 eV, refractive indices of Au (bottom layer), Ni (top layer), and vacuum are increased from the bottom to the top of the layers, and a supplemental enhancement of reflectivity can be expected by optimizing the thickness of the top layer. Thus, the thickness of Ni and the incidence angle were chosen to be 8.0 nm and 86.00°, respectively. To maintain dispersion and spectral resolution of the grating used at an incidence angle of 87.07° as previously designed, groove density was increased to 1500 lines/mm from 1200 lines/mm of our previous design. Finally, a holographic, varied-line-spacing, spherical grating was designed assuming an aspherical-wavefront-recording configuration. The numerical simulation results showed that the spectrograph employing newly designed grating with laminar-type grooves and Au/Ni bilayer coating exhibited 2–18 times higher spectral flux as well as an improved spectral resolution compared with those obtained with the previously designed gratings and spectrographs.
- 1 December 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (12)
Design of soft x-ray high diffraction efficiency and spectral flux Au/Ni bilayer coated laminar-type diffraction grating for objective soft x-ray flat-field spectrograph in a region of 250–550 eV
An objective soft x-ray flat-field spectrograph employing a laminar-type bilayer coated, varied-line-spacing, spherical grating was designed to improve the detection limit and sensitivity of soft x-ray flat-field spectrographs in a region of 250–550 eV. As a design criterion, spectral flux, SF, [Hatano et al., Appl. Opt. 60, 4993–4999 (2021)], which is proportional to the amount of optical flux incident onto a detector and correlated with detection sensitivity, was used to be maximized. To enhance reflectivity with the coating design, Au/Ni bilayer coating was investigated to optimize the incidence angle and thickness of the Ni layer. This is based on the consideration that, in an energy region of over 400 eV, refractive indices of Au (bottom layer), Ni (top layer), and vacuum are increased from the bottom to the top of the layers, and a supplemental enhancement of reflectivity can be expected by optimizing the thickness of the top layer. Thus, the thickness of Ni and the incidence angle were chosen to be 8.0 nm and 86.00°, respectively. To maintain dispersion and spectral resolution of the grating used at an incidence angle of 87.07° as previously designed, groove density was increased to 1500 lines/mm from 1200 lines/mm of our previous design. Finally, a holographic, varied-line-spacing, spherical grating was designed assuming an aspherical-wavefront-recording configuration. The numerical simulation results showed that the spectrograph employing newly designed grating with laminar-type grooves and Au/Ni bilayer coating exhibited 2–18 times higher spectral flux as well as an improved spectral resolution compared with those obtained with the previously designed gratings and spectrographs.
- 1 July 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (7)
Soft x-ray high diffraction efficiency and spectral flux laminar-type W/B4C multilayer diffraction grating for 300–1000 eV
Multilayer diffraction gratings are designed to improve the detection limit and sensitivity of soft x-ray flat-field spectrographs in the region of 300–1000 eV, placing emphasis on Fe-L (705 eV), Cu-L (930 eV), and Zn-L (1012 eV) emissions. For this purpose, spectral flux was used as the performance index, which is proportional to the amount of optical flux incident into a detector and correlated with detection sensitivity. A super-mirror-type W/B4C multilayer coating [Koike et al., Rev.Sci. Instrum. 94, 045109 (2023)] was employed to improve diffraction efficiency in a wide energy region. The unique feature of the multilayer structure is that the average refractive index and the period length of W/B4C layer pairs are increased from the bottom to top layers. In addition, the incidence angle was reduced to 86.03° from 88.65° and the nominal groove density was increased to 3200 lines/mm from 2400 lines/mm of our previous design, to improve spectral flux while maintaining dispersion and spectral resolution. A holographic varied-line-spacing spherical grating and a soft x-ray flat-field spectrograph were designed, using the aspherical-wavefront-recording method, assuming the nominal grating constant and incident angle described above. The numerical simulation results showed that the spectrograph employing the newly designed grating with the W/B4C multilayer indicated 3.2–8.2 times higher spectral flux compared with those using the previously designed grating while keeping the same spectral resolution.
- 1 July 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (7)
Soft x-ray high diffraction efficiency and spectral flux laminar-type W/B4C multilayer diffraction grating for 300–1000 eV
Multilayer diffraction gratings are designed to improve the detection limit and sensitivity of soft x-ray flat-field spectrographs in the region of 300–1000 eV, placing emphasis on Fe-L (705 eV), Cu-L (930 eV), and Zn-L (1012 eV) emissions. For this purpose, spectral flux was used as the performance index, which is proportional to the amount of optical flux incident into a detector and correlated with detection sensitivity. A super-mirror-type W/B4C multilayer coating [Koike et al., Rev.Sci. Instrum. 94, 045109 (2023)] was employed to improve diffraction efficiency in a wide energy region. The unique feature of the multilayer structure is that the average refractive index and the period length of W/B4C layer pairs are increased from the bottom to top layers. In addition, the incidence angle was reduced to 86.03° from 88.65° and the nominal groove density was increased to 3200 lines/mm from 2400 lines/mm of our previous design, to improve spectral flux while maintaining dispersion and spectral resolution. A holographic varied-line-spacing spherical grating and a soft x-ray flat-field spectrograph were designed, using the aspherical-wavefront-recording method, assuming the nominal grating constant and incident angle described above. The numerical simulation results showed that the spectrograph employing the newly designed grating with the W/B4C multilayer indicated 3.2–8.2 times higher spectral flux compared with those using the previously designed grating while keeping the same spectral resolution.
- Open Access
- 1 December 2023
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 94 (12)
Laminar-type gratings overcoated with carbon-based materials to enhance analytical sensitivity of flat-field emission spectrograph in the VUV region
Laminar-type spherical diffraction gratings overcoated with carbon-based materials were designed, fabricated, and evaluated for the purpose of enhancing the analytical sensitivity of the flat-field spectrograph in a vacuum ultraviolet region of 35–110 eV. As the design benchmark for numerical calculations, diffraction efficiency (DE) and spectral flux, which are defined by the product of the DE and numerical aperture and correlate with the analytical sensitivity of the spectrograph, were used. To simplify the feasibility study on the overcoating effects, we assumed a laminar-type grating having a grating constant of 1/1000 mm and coated with a Au layer of 30.0 nm thickness and an incidence angle of 84.0°. The optimized groove depth and duty ratio were 30.0 nm and 0.3, respectively. In addition, the optimum thicknesses of the overcoating layer were 44, 46, 24, and 30 nm for B4C, C, diamond-like-carbon, and SiC, respectively. Based on these results, we have fabricated a varied-line-spacing holographic grating overcoated with B4C with a thickness of 47 nm. For the experimental evaluation, we used the light source of Mg-L and Al-L emissions excited by the electron beam generated from an electron microscope, an objective flat-field spectrograph, and a CCD imaging detector. The experimental results showed that the spectrograph employing a new grating overcoated with the B4C layer indicated almost the same spectral resolution and 2.9–4.2 times higher analytical sensitivity compared with those obtained with a previously designed Au-coated grating having a grating constant of 1/1200 mm and used at an incidence of 86.0°.
- 1 December 2023
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 94 (12)
Open AccessLaminar-type gratings overcoated with carbon-based materials to enhance analytical sensitivity of flat-field emission spectrograph in the VUV region
Laminar-type spherical diffraction gratings overcoated with carbon-based materials were designed, fabricated, and evaluated for the purpose of enhancing the analytical sensitivity of the flat-field spectrograph in a vacuum ultraviolet region of 35–110 eV. As the design benchmark for numerical calculations, diffraction efficiency (DE) and spectral flux, which are defined by the product of the DE and numerical aperture and correlate with the analytical sensitivity of the spectrograph, were used. To simplify the feasibility study on the overcoating effects, we assumed a laminar-type grating having a grating constant of 1/1000 mm and coated with a Au layer of 30.0 nm thickness and an incidence angle of 84.0°. The optimized groove depth and duty ratio were 30.0 nm and 0.3, respectively. In addition, the optimum thicknesses of the overcoating layer were 44, 46, 24, and 30 nm for B4C, C, diamond-like-carbon, and SiC, respectively. Based on these results, we have fabricated a varied-line-spacing holographic grating overcoated with B4C with a thickness of 47 nm. For the experimental evaluation, we used the light source of Mg-L and Al-L emissions excited by the electron beam generated from an electron microscope, an objective flat-field spectrograph, and a CCD imaging detector. The experimental results showed that the spectrograph employing a new grating overcoated with the B4C layer indicated almost the same spectral resolution and 2.9–4.2 times higher analytical sensitivity compared with those obtained with a previously designed Au-coated grating having a grating constant of 1/1200 mm and used at an incidence of 86.0°.