Masato Koike
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Masato Koike has a total of 34 co-authors. Here are the top co-authors by number of shared publications:
- Alexander Sergeevich Pirozhkov
Kansai Institute for Photon Science (KPSI), National Institutes for Quantum Science and Technology (QST), Kyoto, Japan
6 shared publications - Masami Terauchi
Tohoku Center of Excellence for Microscopy (TCEM), Tohoku University , 2-1-1 Katahira, Aoba-ku , Sendai, Miyagi 980-8577
5 shared publications - Tadashi Hatano
International Center for Synchrotron Radiation Innovation Smart (SRIS), Tohoku University 1 , 2-1-1 Katahira, Aoba-ku, Sendai, Miyagi 980-8577
5 shared publications - Kiminori Kondo
Kansai Institute for Photon Science, National Institutes for Quantum Science and Technology (QST) 1 , 8-1-7 Umemidai, Kizugawa, Kyoto 619-0215
3 shared publications - Shogo Koshiya
SA Research and Development Department, SA Business Unit, JEOL Ltd , 3-1-2 Musashino , Akishima, Tokyo 196-8558
3 shared publications T. Kakio
Device Department, Shimadzu Corporation 7 , Nakagyu-ku, Kyoto, Kyoto 604-8511
3 shared publications
Latest Publications
- Open Access
- 16 October 2026
- Published by Wolters Kluwer Health in Medicine
- Vol. 105 (42) , e51197
Additive effects of active vitamin D3 or vitamin E administration on therapeutic lower-limb home exercise for knee osteoarthritis
Background: Quadriceps weakness, inflammation, and reduced physical function are common in knee osteoarthritis (OA), and lower limb exercise therapy is an established non-pharmacological treatment. Vitamin D3 (vit D3) and vitamin E (vit E) have been proposed as adjunctive therapies; however, clinical findings are inconsistent. We aimed to examine whether combining lower limb home exercises with oral active vit D3 or vit E supplementation provides additive benefits compared with home exercise alone in women with symptomatic knee OA. Methods: Eighty-eight postmenopausal women with knee OA (Kellgren–Lawrence grade 2–4; 71.9 ± 5.6 years) were randomly assigned to receive therapeutic lower limb home exercise only, home exercise with active vit D3 administration, or home exercise with vit E administration. Participants performed isometric lower limb exercises twice daily for 24 weeks. Subsequently, they were assessed using the Japanese knee osteoarthritis measure (JKOM) as the primary outcome. Secondary outcomes were short-form health survey, grip strength, quadriceps muscle strength, 10-m walk test, inflammatory markers, bone mineral density, and body composition. For data analyses, we used paired and independent t tests, analysis of variance, and analysis of covariance, adjusting for age, body mass index, and Kellgren–Lawrence grade. Results: Eighty participants completed follow-up. All groups showed significant improvements in JKOM score, quadriceps muscle strength, and 10-m walk test. Grip strength improved significantly only in the group that received active vit D. No significant between-group differences were observed in JKOM scores, short-form health survey-36, muscle strength, or physical performance. Inflammatory markers decreased significantly in the vit E group, although between-group differences were not observed. No other significant between-group differences were found, except in bone mineral density. Conclusions: Administering active vit D3 or vit E for 24 weeks as an adjunct to lower limb home exercises did not yield significant additive effects on symptoms, muscle strength, or physical performance in women with knee OA. Exercise therapy alone remained effective, and vitamin supplementation showed nutrient-specific trends.
- 16 October 2026
- Published by Wolters Kluwer Health in Medicine
- Vol. 105 (42) , e51197
Open AccessAdditive effects of active vitamin D3 or vitamin E administration on therapeutic lower-limb home exercise for knee osteoarthritis
Background: Quadriceps weakness, inflammation, and reduced physical function are common in knee osteoarthritis (OA), and lower limb exercise therapy is an established non-pharmacological treatment. Vitamin D3 (vit D3) and vitamin E (vit E) have been proposed as adjunctive therapies; however, clinical findings are inconsistent. We aimed to examine whether combining lower limb home exercises with oral active vit D3 or vit E supplementation provides additive benefits compared with home exercise alone in women with symptomatic knee OA. Methods: Eighty-eight postmenopausal women with knee OA (Kellgren–Lawrence grade 2–4; 71.9 ± 5.6 years) were randomly assigned to receive therapeutic lower limb home exercise only, home exercise with active vit D3 administration, or home exercise with vit E administration. Participants performed isometric lower limb exercises twice daily for 24 weeks. Subsequently, they were assessed using the Japanese knee osteoarthritis measure (JKOM) as the primary outcome. Secondary outcomes were short-form health survey, grip strength, quadriceps muscle strength, 10-m walk test, inflammatory markers, bone mineral density, and body composition. For data analyses, we used paired and independent t tests, analysis of variance, and analysis of covariance, adjusting for age, body mass index, and Kellgren–Lawrence grade. Results: Eighty participants completed follow-up. All groups showed significant improvements in JKOM score, quadriceps muscle strength, and 10-m walk test. Grip strength improved significantly only in the group that received active vit D. No significant between-group differences were observed in JKOM scores, short-form health survey-36, muscle strength, or physical performance. Inflammatory markers decreased significantly in the vit E group, although between-group differences were not observed. No other significant between-group differences were found, except in bone mineral density. Conclusions: Administering active vit D3 or vit E for 24 weeks as an adjunct to lower limb home exercises did not yield significant additive effects on symptoms, muscle strength, or physical performance in women with knee OA. Exercise therapy alone remained effective, and vitamin supplementation showed nutrient-specific trends.
- 1 September 2026
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 97 (9)
Soft x-ray laminar-type varied-line-spacing multilayer spherical diffraction grating designed for a flat-field grating spectrograph with enhanced spectral flux in the 1–2 keV region
A soft x-ray diffraction grating with an aperiodic multilayer coating was designed to enhance spectral flux in a photon energy range of 1–2 keV by means of numerical calculation. Optimized groove depth and angle of incidence were 2.65 nm and 87.50°, respectively, for the grating with a groove density of 2400 lines/mm. The optimum number of W/B4C layer pairs was 6; the thicknesses of four bottom B4C layers were constant, and those of two top layers were unequal, while all W layer thicknesses were the same. An additional top layer of Au was crucial to provide uniform diffraction efficiency across the spectral range. In the region of 1–2 keV, the calculated diffraction efficiency of the designed gratings was ∼4.4% on average, and the calculated spectral flux (which correlates with analytical sensitivity) was 2.8 times larger than that of a previously designed Au-coated grating with an angle of incidence of 88.65°. The designed grating was manufactured; its measured diffraction efficiency was close to the calculated one in the 0.6–1.4 keV and >2 keV spectral ranges but somewhat lower in the 1.6–1.8 keV range. The spectrograph equipped with the new grating exhibited resolving power exceeding 400, which approached the pixel-size limit.
- 1 September 2026
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 97 (9)
Soft x-ray laminar-type varied-line-spacing multilayer spherical diffraction grating designed for a flat-field grating spectrograph with enhanced spectral flux in the 1–2 keV region
A soft x-ray diffraction grating with an aperiodic multilayer coating was designed to enhance spectral flux in a photon energy range of 1–2 keV by means of numerical calculation. Optimized groove depth and angle of incidence were 2.65 nm and 87.50°, respectively, for the grating with a groove density of 2400 lines/mm. The optimum number of W/B4C layer pairs was 6; the thicknesses of four bottom B4C layers were constant, and those of two top layers were unequal, while all W layer thicknesses were the same. An additional top layer of Au was crucial to provide uniform diffraction efficiency across the spectral range. In the region of 1–2 keV, the calculated diffraction efficiency of the designed gratings was ∼4.4% on average, and the calculated spectral flux (which correlates with analytical sensitivity) was 2.8 times larger than that of a previously designed Au-coated grating with an angle of incidence of 88.65°. The designed grating was manufactured; its measured diffraction efficiency was close to the calculated one in the 0.6–1.4 keV and >2 keV spectral ranges but somewhat lower in the 1.6–1.8 keV range. The spectrograph equipped with the new grating exhibited resolving power exceeding 400, which approached the pixel-size limit.
- 1 December 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (12)
Design of soft x-ray high diffraction efficiency and spectral flux Au/Ni bilayer coated laminar-type diffraction grating for objective soft x-ray flat-field spectrograph in a region of 250–550 eV
An objective soft x-ray flat-field spectrograph employing a laminar-type bilayer coated, varied-line-spacing, spherical grating was designed to improve the detection limit and sensitivity of soft x-ray flat-field spectrographs in a region of 250–550 eV. As a design criterion, spectral flux, SF, [Hatano et al., Appl. Opt. 60, 4993–4999 (2021)], which is proportional to the amount of optical flux incident onto a detector and correlated with detection sensitivity, was used to be maximized. To enhance reflectivity with the coating design, Au/Ni bilayer coating was investigated to optimize the incidence angle and thickness of the Ni layer. This is based on the consideration that, in an energy region of over 400 eV, refractive indices of Au (bottom layer), Ni (top layer), and vacuum are increased from the bottom to the top of the layers, and a supplemental enhancement of reflectivity can be expected by optimizing the thickness of the top layer. Thus, the thickness of Ni and the incidence angle were chosen to be 8.0 nm and 86.00°, respectively. To maintain dispersion and spectral resolution of the grating used at an incidence angle of 87.07° as previously designed, groove density was increased to 1500 lines/mm from 1200 lines/mm of our previous design. Finally, a holographic, varied-line-spacing, spherical grating was designed assuming an aspherical-wavefront-recording configuration. The numerical simulation results showed that the spectrograph employing newly designed grating with laminar-type grooves and Au/Ni bilayer coating exhibited 2–18 times higher spectral flux as well as an improved spectral resolution compared with those obtained with the previously designed gratings and spectrographs.
- 1 December 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (12)
Design of soft x-ray high diffraction efficiency and spectral flux Au/Ni bilayer coated laminar-type diffraction grating for objective soft x-ray flat-field spectrograph in a region of 250–550 eV
An objective soft x-ray flat-field spectrograph employing a laminar-type bilayer coated, varied-line-spacing, spherical grating was designed to improve the detection limit and sensitivity of soft x-ray flat-field spectrographs in a region of 250–550 eV. As a design criterion, spectral flux, SF, [Hatano et al., Appl. Opt. 60, 4993–4999 (2021)], which is proportional to the amount of optical flux incident onto a detector and correlated with detection sensitivity, was used to be maximized. To enhance reflectivity with the coating design, Au/Ni bilayer coating was investigated to optimize the incidence angle and thickness of the Ni layer. This is based on the consideration that, in an energy region of over 400 eV, refractive indices of Au (bottom layer), Ni (top layer), and vacuum are increased from the bottom to the top of the layers, and a supplemental enhancement of reflectivity can be expected by optimizing the thickness of the top layer. Thus, the thickness of Ni and the incidence angle were chosen to be 8.0 nm and 86.00°, respectively. To maintain dispersion and spectral resolution of the grating used at an incidence angle of 87.07° as previously designed, groove density was increased to 1500 lines/mm from 1200 lines/mm of our previous design. Finally, a holographic, varied-line-spacing, spherical grating was designed assuming an aspherical-wavefront-recording configuration. The numerical simulation results showed that the spectrograph employing newly designed grating with laminar-type grooves and Au/Ni bilayer coating exhibited 2–18 times higher spectral flux as well as an improved spectral resolution compared with those obtained with the previously designed gratings and spectrographs.
- 1 July 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (7)
Soft x-ray high diffraction efficiency and spectral flux laminar-type W/B4C multilayer diffraction grating for 300–1000 eV
Multilayer diffraction gratings are designed to improve the detection limit and sensitivity of soft x-ray flat-field spectrographs in the region of 300–1000 eV, placing emphasis on Fe-L (705 eV), Cu-L (930 eV), and Zn-L (1012 eV) emissions. For this purpose, spectral flux was used as the performance index, which is proportional to the amount of optical flux incident into a detector and correlated with detection sensitivity. A super-mirror-type W/B4C multilayer coating [Koike et al., Rev.Sci. Instrum. 94, 045109 (2023)] was employed to improve diffraction efficiency in a wide energy region. The unique feature of the multilayer structure is that the average refractive index and the period length of W/B4C layer pairs are increased from the bottom to top layers. In addition, the incidence angle was reduced to 86.03° from 88.65° and the nominal groove density was increased to 3200 lines/mm from 2400 lines/mm of our previous design, to improve spectral flux while maintaining dispersion and spectral resolution. A holographic varied-line-spacing spherical grating and a soft x-ray flat-field spectrograph were designed, using the aspherical-wavefront-recording method, assuming the nominal grating constant and incident angle described above. The numerical simulation results showed that the spectrograph employing the newly designed grating with the W/B4C multilayer indicated 3.2–8.2 times higher spectral flux compared with those using the previously designed grating while keeping the same spectral resolution.
- 1 July 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (7)
Soft x-ray high diffraction efficiency and spectral flux laminar-type W/B4C multilayer diffraction grating for 300–1000 eV
Multilayer diffraction gratings are designed to improve the detection limit and sensitivity of soft x-ray flat-field spectrographs in the region of 300–1000 eV, placing emphasis on Fe-L (705 eV), Cu-L (930 eV), and Zn-L (1012 eV) emissions. For this purpose, spectral flux was used as the performance index, which is proportional to the amount of optical flux incident into a detector and correlated with detection sensitivity. A super-mirror-type W/B4C multilayer coating [Koike et al., Rev.Sci. Instrum. 94, 045109 (2023)] was employed to improve diffraction efficiency in a wide energy region. The unique feature of the multilayer structure is that the average refractive index and the period length of W/B4C layer pairs are increased from the bottom to top layers. In addition, the incidence angle was reduced to 86.03° from 88.65° and the nominal groove density was increased to 3200 lines/mm from 2400 lines/mm of our previous design, to improve spectral flux while maintaining dispersion and spectral resolution. A holographic varied-line-spacing spherical grating and a soft x-ray flat-field spectrograph were designed, using the aspherical-wavefront-recording method, assuming the nominal grating constant and incident angle described above. The numerical simulation results showed that the spectrograph employing the newly designed grating with the W/B4C multilayer indicated 3.2–8.2 times higher spectral flux compared with those using the previously designed grating while keeping the same spectral resolution.
- Open Access
- 1 February 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (2)
Design of soft x-ray varied-line-spacing (VLS) high-dispersion laminar-type grating coated with super-mirror-type (SMT) multilayer for flat-field spectrograph in a region of 2–4 keV
A soft x-ray varied-line-spacing (VLS) laminar-type spherical grating with a super-mirror-type (SMT) multilayer was designed for a soft x-ray high resolution flat-field spectrograph in a region of 2–4 keV. The effective groove density of the designed VLS grating is 3200 lines/mm, and the local groove density varies from 2700 to 3866 lines/mm. The geometrical imaging property was evaluated by numerical calculations. The resolving power estimated by means of ray tracing was up to ∼103. For the evaluation of diffraction efficiency, the SMT multilayer structure designed for 3200 lines/mm in our previous work, Koike et al., Rev. Sci. Instrum. 94, 045109 (2023), was employed, and the numerical calculation was performed considering the local groove density of VLS grooves and the local incidence angle being affected by the curvature of the spherical surface and the geometrical relation between the source and incidence point on the grating. The results showed that the SMT multilayer-coated grating exhibited about an order of magnitude higher diffraction efficiency compared with an Au-coated grating.
- 1 February 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (2)
Open AccessDesign of soft x-ray varied-line-spacing (VLS) high-dispersion laminar-type grating coated with super-mirror-type (SMT) multilayer for flat-field spectrograph in a region of 2–4 keV
A soft x-ray varied-line-spacing (VLS) laminar-type spherical grating with a super-mirror-type (SMT) multilayer was designed for a soft x-ray high resolution flat-field spectrograph in a region of 2–4 keV. The effective groove density of the designed VLS grating is 3200 lines/mm, and the local groove density varies from 2700 to 3866 lines/mm. The geometrical imaging property was evaluated by numerical calculations. The resolving power estimated by means of ray tracing was up to ∼103. For the evaluation of diffraction efficiency, the SMT multilayer structure designed for 3200 lines/mm in our previous work, Koike et al., Rev. Sci. Instrum. 94, 045109 (2023), was employed, and the numerical calculation was performed considering the local groove density of VLS grooves and the local incidence angle being affected by the curvature of the spherical surface and the geometrical relation between the source and incidence point on the grating. The results showed that the SMT multilayer-coated grating exhibited about an order of magnitude higher diffraction efficiency compared with an Au-coated grating.
- Open Access
- 1 December 2023
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 94 (12)
Laminar-type gratings overcoated with carbon-based materials to enhance analytical sensitivity of flat-field emission spectrograph in the VUV region
Laminar-type spherical diffraction gratings overcoated with carbon-based materials were designed, fabricated, and evaluated for the purpose of enhancing the analytical sensitivity of the flat-field spectrograph in a vacuum ultraviolet region of 35–110 eV. As the design benchmark for numerical calculations, diffraction efficiency (DE) and spectral flux, which are defined by the product of the DE and numerical aperture and correlate with the analytical sensitivity of the spectrograph, were used. To simplify the feasibility study on the overcoating effects, we assumed a laminar-type grating having a grating constant of 1/1000 mm and coated with a Au layer of 30.0 nm thickness and an incidence angle of 84.0°. The optimized groove depth and duty ratio were 30.0 nm and 0.3, respectively. In addition, the optimum thicknesses of the overcoating layer were 44, 46, 24, and 30 nm for B4C, C, diamond-like-carbon, and SiC, respectively. Based on these results, we have fabricated a varied-line-spacing holographic grating overcoated with B4C with a thickness of 47 nm. For the experimental evaluation, we used the light source of Mg-L and Al-L emissions excited by the electron beam generated from an electron microscope, an objective flat-field spectrograph, and a CCD imaging detector. The experimental results showed that the spectrograph employing a new grating overcoated with the B4C layer indicated almost the same spectral resolution and 2.9–4.2 times higher analytical sensitivity compared with those obtained with a previously designed Au-coated grating having a grating constant of 1/1200 mm and used at an incidence of 86.0°.
- 1 December 2023
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 94 (12)
Open AccessLaminar-type gratings overcoated with carbon-based materials to enhance analytical sensitivity of flat-field emission spectrograph in the VUV region
Laminar-type spherical diffraction gratings overcoated with carbon-based materials were designed, fabricated, and evaluated for the purpose of enhancing the analytical sensitivity of the flat-field spectrograph in a vacuum ultraviolet region of 35–110 eV. As the design benchmark for numerical calculations, diffraction efficiency (DE) and spectral flux, which are defined by the product of the DE and numerical aperture and correlate with the analytical sensitivity of the spectrograph, were used. To simplify the feasibility study on the overcoating effects, we assumed a laminar-type grating having a grating constant of 1/1000 mm and coated with a Au layer of 30.0 nm thickness and an incidence angle of 84.0°. The optimized groove depth and duty ratio were 30.0 nm and 0.3, respectively. In addition, the optimum thicknesses of the overcoating layer were 44, 46, 24, and 30 nm for B4C, C, diamond-like-carbon, and SiC, respectively. Based on these results, we have fabricated a varied-line-spacing holographic grating overcoated with B4C with a thickness of 47 nm. For the experimental evaluation, we used the light source of Mg-L and Al-L emissions excited by the electron beam generated from an electron microscope, an objective flat-field spectrograph, and a CCD imaging detector. The experimental results showed that the spectrograph employing a new grating overcoated with the B4C layer indicated almost the same spectral resolution and 2.9–4.2 times higher analytical sensitivity compared with those obtained with a previously designed Au-coated grating having a grating constant of 1/1200 mm and used at an incidence of 86.0°.
- Open Access
- 1 April 2023
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 94 (4)
Design of soft x-ray laminar-type gratings coated with supermirror-type multilayer to enhance diffraction efficiency in a region of 2–4 keV
Soft x-ray diffraction gratings coated with a supermirror-type multilayer were designed to enhance diffraction efficiency in the energy range of 2–4 keV by means of numerical calculations. The optimized groove depth and incidence angle are 2.05 nm and 88.65°, respectively, for the grating having a groove density of 3200 grooves/mm. Regarding the multilayer structure, the optimum number of B4C/W layers pair was 11 and the thickness of B4C was increased from bottom to top, while that of W was kept constant. The replacement of the top layer of W by either Co, Cr, or Ni was an effective means of obtaining uniform diffraction efficiency. In the region of 2–4 keV, the calculated diffraction efficiency of the designed gratings was up to ∼5.3%, on average, and almost eight times larger than that of ∼0.7% of an Au coated grating.
- 1 April 2023
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 94 (4)
Open AccessDesign of soft x-ray laminar-type gratings coated with supermirror-type multilayer to enhance diffraction efficiency in a region of 2–4 keV
Soft x-ray diffraction gratings coated with a supermirror-type multilayer were designed to enhance diffraction efficiency in the energy range of 2–4 keV by means of numerical calculations. The optimized groove depth and incidence angle are 2.05 nm and 88.65°, respectively, for the grating having a groove density of 3200 grooves/mm. Regarding the multilayer structure, the optimum number of B4C/W layers pair was 11 and the thickness of B4C was increased from bottom to top, while that of W was kept constant. The replacement of the top layer of W by either Co, Cr, or Ni was an effective means of obtaining uniform diffraction efficiency. In the region of 2–4 keV, the calculated diffraction efficiency of the designed gratings was up to ∼5.3%, on average, and almost eight times larger than that of ∼0.7% of an Au coated grating.
- 20 April 2003
- Published by Optica Publishing Group in Applied Optics
- Vol. 42 (12) , 2198-2205
Development of a pumping laser system for x-ray laser research
A two-beam chirped-pulse-amplification Nd:glass laser system dedicated to x-ray laser research is described. Each beam provides an output energy of 20 J with a typical pulse duration of 1.3 ps. A prepulse of variable duration is generated by use of a novel, to our knowledge, optical system. A reflection optical system, comprised of an off-axis parabolic mirror and a spherical mirror, produces a line focus with 6-mm length and 15-μm width without chromatic aberration. By use of this pumping laser system, the nickel-like silver x-ray laser at a wavelength of 13.9 nm has been demonstrated.
- 20 April 2003
- Published by Optica Publishing Group in Applied Optics
- Vol. 42 (12) , 2198-2205
Development of a pumping laser system for x-ray laser research
A two-beam chirped-pulse-amplification Nd:glass laser system dedicated to x-ray laser research is described. Each beam provides an output energy of 20 J with a typical pulse duration of 1.3 ps. A prepulse of variable duration is generated by use of a novel, to our knowledge, optical system. A reflection optical system, comprised of an off-axis parabolic mirror and a spherical mirror, produces a line focus with 6-mm length and 15-μm width without chromatic aberration. By use of this pumping laser system, the nickel-like silver x-ray laser at a wavelength of 13.9 nm has been demonstrated.