Masami Terauchi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Masami Terauchi has a total of 64 co-authors. Here are the top co-authors by number of shared publications:
- Alexander Sergeevich Pirozhkov
Kansai Institute for Photon Science (KPSI), National Institutes for Quantum Science and Technology (QST), Kyoto, Japan
5 shared publications - Masato Koike
Department of Orthopaedics, Juntendo University Faculty of Medicine, Bunkyo-ku, Tokyo, Japan
5 shared publications Yohei K Sato
Institute of Multidisciplinary Research for Advanced Materials, Tohoku University , 2-1-1, Katahira, Aobaku, Sendai 980-8577
5 shared publications- Shogo Koshiya
SA Research and Development Department, SA Business Unit, JEOL Ltd , 3-1-2 Musashino , Akishima, Tokyo 196-8558
4 shared publications - Tadashi Hatano
International Center for Synchrotron Radiation Innovation Smart (SRIS), Tohoku University 1 , 2-1-1 Katahira, Aoba-ku, Sendai, Miyagi 980-8577
4 shared publications - Yohei K. Sato
Institute of Multidisciplinary Research for Advanced Materials (IMRAM), Tohoku University , 2-1-1 Katahira, Aoba-ku , Sendai, Miyagi 980-8577
4 shared publications
Latest Publications
- 1 September 2026
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 97 (9)
Soft x-ray laminar-type varied-line-spacing multilayer spherical diffraction grating designed for a flat-field grating spectrograph with enhanced spectral flux in the 1–2 keV region
A soft x-ray diffraction grating with an aperiodic multilayer coating was designed to enhance spectral flux in a photon energy range of 1–2 keV by means of numerical calculation. Optimized groove depth and angle of incidence were 2.65 nm and 87.50°, respectively, for the grating with a groove density of 2400 lines/mm. The optimum number of W/B4C layer pairs was 6; the thicknesses of four bottom B4C layers were constant, and those of two top layers were unequal, while all W layer thicknesses were the same. An additional top layer of Au was crucial to provide uniform diffraction efficiency across the spectral range. In the region of 1–2 keV, the calculated diffraction efficiency of the designed gratings was ∼4.4% on average, and the calculated spectral flux (which correlates with analytical sensitivity) was 2.8 times larger than that of a previously designed Au-coated grating with an angle of incidence of 88.65°. The designed grating was manufactured; its measured diffraction efficiency was close to the calculated one in the 0.6–1.4 keV and >2 keV spectral ranges but somewhat lower in the 1.6–1.8 keV range. The spectrograph equipped with the new grating exhibited resolving power exceeding 400, which approached the pixel-size limit.
- 1 September 2026
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 97 (9)
Soft x-ray laminar-type varied-line-spacing multilayer spherical diffraction grating designed for a flat-field grating spectrograph with enhanced spectral flux in the 1–2 keV region
A soft x-ray diffraction grating with an aperiodic multilayer coating was designed to enhance spectral flux in a photon energy range of 1–2 keV by means of numerical calculation. Optimized groove depth and angle of incidence were 2.65 nm and 87.50°, respectively, for the grating with a groove density of 2400 lines/mm. The optimum number of W/B4C layer pairs was 6; the thicknesses of four bottom B4C layers were constant, and those of two top layers were unequal, while all W layer thicknesses were the same. An additional top layer of Au was crucial to provide uniform diffraction efficiency across the spectral range. In the region of 1–2 keV, the calculated diffraction efficiency of the designed gratings was ∼4.4% on average, and the calculated spectral flux (which correlates with analytical sensitivity) was 2.8 times larger than that of a previously designed Au-coated grating with an angle of incidence of 88.65°. The designed grating was manufactured; its measured diffraction efficiency was close to the calculated one in the 0.6–1.4 keV and >2 keV spectral ranges but somewhat lower in the 1.6–1.8 keV range. The spectrograph equipped with the new grating exhibited resolving power exceeding 400, which approached the pixel-size limit.
- 10 June 2026
- Published by Oxford University Press (OUP) in Microscopy
Capability of angle-resolved SXES experiment examined by hexagonal BN and its application for the chemical bonding state of Fe2B
The angle-dependences of N-K emission intensity profile of hBN on polar angle θ and azimuth angle ϕ were examined. The θ-dependent N-K emission intensity profiles show different angle dependences in the top and the bottom region of valence band (VB). From the comparison with the theoretically calculated charge distributions, there was a clear relation between the θ-dependence and the corresponding charge distribution was confirmed. No ϕ-dependence of N-K profile was observed and confirmed by a simple calculation, which shows no ϕ-dependence is reasonable for 3-, 4-, 6-fold symmetrical charge distribution with the same energy. Important factor is the angle θ between a specified axis of the extend/reduce of charge distribution and the detection direction. From the angle dependent B-K emission profile of Fe2B, the presence of the interlayer one-dimensional B-B bonding of pz orbital was assigned at the bottom of VB. For discussing the anisotropic charge distribution in materials other than graphite and hBN, an anisotropy index α(E) was proposed and evaluated for the present experimental data.
- 10 June 2026
- Published by Oxford University Press (OUP) in Microscopy
Capability of angle-resolved SXES experiment examined by hexagonal BN and its application for the chemical bonding state of Fe2B
The angle-dependences of N-K emission intensity profile of hBN on polar angle θ and azimuth angle ϕ were examined. The θ-dependent N-K emission intensity profiles show different angle dependences in the top and the bottom region of valence band (VB). From the comparison with the theoretically calculated charge distributions, there was a clear relation between the θ-dependence and the corresponding charge distribution was confirmed. No ϕ-dependence of N-K profile was observed and confirmed by a simple calculation, which shows no ϕ-dependence is reasonable for 3-, 4-, 6-fold symmetrical charge distribution with the same energy. Important factor is the angle θ between a specified axis of the extend/reduce of charge distribution and the detection direction. From the angle dependent B-K emission profile of Fe2B, the presence of the interlayer one-dimensional B-B bonding of pz orbital was assigned at the bottom of VB. For discussing the anisotropic charge distribution in materials other than graphite and hBN, an anisotropy index α(E) was proposed and evaluated for the present experimental data.
- 30 December 2025
- Published by Oxford University Press (OUP) in Microscopy
- Vol. 75 (2) , 195-208
Valence electron spectroscopy using soft X-ray emission spectroscopy electron microscopes
Compact soft-X-ray emission spectroscopy (SXES) instrument, which was first applied to transmission electron microscope, was recently applied to scanning electron microscope and electron-probe microanalyzer, which improved the practical applicability of SXES as a tool for investigating chemical bonding state of elements in bulk materials. Intensity profiles of Al-L, B-K and Si-L emission spectra, which directly reflect the partial density of state of valence band (VB), were explained. Those energy positions are affected by core-level shift (chemical shift, CS) and a change of density of state (DOS) of VB, for example a bandgap formation. Those VB DOS measurements, combined with electron-beam scanning technique, can conduct a chemical bond mapping of a bulk material. It was presented that L-emission spectra of 3d transition-metal elements give DOS+CS information in Lα,β emission, dielectric information in Lℓ,η, and the number of 3d electrons in the integrated intensity ratio of Lα,β/(Lα,β+ Lℓ,η). Since the electron-beam excited SXES experiment for bulk specimens can control the self-absorption effect, L-absorption profile of 3d-TM elements is obtainable from L-emission measurements by changing the accelerating voltage. Furthermore, CB information can be obtained from SXES spectra of semiconductor materials; Si and diamond cases were presented, by using the self-absorption effect on the background intensity of bremsstrahlung (BS) caused by electron-beam irradiation of the specimen.
- 30 December 2025
- Published by Oxford University Press (OUP) in Microscopy
- Vol. 75 (2) , 195-208
Valence electron spectroscopy using soft X-ray emission spectroscopy electron microscopes
Compact soft-X-ray emission spectroscopy (SXES) instrument, which was first applied to transmission electron microscope, was recently applied to scanning electron microscope and electron-probe microanalyzer, which improved the practical applicability of SXES as a tool for investigating chemical bonding state of elements in bulk materials. Intensity profiles of Al-L, B-K and Si-L emission spectra, which directly reflect the partial density of state of valence band (VB), were explained. Those energy positions are affected by core-level shift (chemical shift, CS) and a change of density of state (DOS) of VB, for example a bandgap formation. Those VB DOS measurements, combined with electron-beam scanning technique, can conduct a chemical bond mapping of a bulk material. It was presented that L-emission spectra of 3d transition-metal elements give DOS+CS information in Lα,β emission, dielectric information in Lℓ,η, and the number of 3d electrons in the integrated intensity ratio of Lα,β/(Lα,β+ Lℓ,η). Since the electron-beam excited SXES experiment for bulk specimens can control the self-absorption effect, L-absorption profile of 3d-TM elements is obtainable from L-emission measurements by changing the accelerating voltage. Furthermore, CB information can be obtained from SXES spectra of semiconductor materials; Si and diamond cases were presented, by using the self-absorption effect on the background intensity of bremsstrahlung (BS) caused by electron-beam irradiation of the specimen.
- 16 April 2025
- Published by Oxford University Press (OUP) in Microscopy
- Vol. 74 (6) , 432-436
High energy-resolution soft X-ray emission spectrometer using a back-thinned CMOS detector for chemical bonding state analysis
Improvement of a commercially available soft X-ray emission spectrometer was tested by introducing a fine-pixel-sized CMOS detector. The peak width of Mg Kα-emission was reduced to one-fourth of that obtained by the CCD detector presently used. Furthermore, the differences in the energy positions of satellite lines of Mg Kα- and also Kβ-emission profiles of Mg and MgO were observed. O K-emission profile of MgO exhibited a few structures reflecting the chemical bonding state. This spectrometer easily discriminated the intensity profiles of Fe Lα,β-emission reflecting the chemical bonding states of Fe atoms in Fe, FeO, Fe3O4 and Fe2O3.
- 16 April 2025
- Published by Oxford University Press (OUP) in Microscopy
- Vol. 74 (6) , 432-436
High energy-resolution soft X-ray emission spectrometer using a back-thinned CMOS detector for chemical bonding state analysis
Improvement of a commercially available soft X-ray emission spectrometer was tested by introducing a fine-pixel-sized CMOS detector. The peak width of Mg Kα-emission was reduced to one-fourth of that obtained by the CCD detector presently used. Furthermore, the differences in the energy positions of satellite lines of Mg Kα- and also Kβ-emission profiles of Mg and MgO were observed. O K-emission profile of MgO exhibited a few structures reflecting the chemical bonding state. This spectrometer easily discriminated the intensity profiles of Fe Lα,β-emission reflecting the chemical bonding states of Fe atoms in Fe, FeO, Fe3O4 and Fe2O3.
- Open Access
- 4 February 2025
- Published by Oxford University Press (OUP) in Microscopy
- Vol. 74 (2) , 117-123
Derivation method of the dielectric function of amorphous materials using angle-resolved electron energy loss spectroscopy for exciton size evaluation
Accurately deriving the momentum transfer dependence of the dielectric function ε(q, ω) using angle-resolved electron energy loss spectroscopy (AR-EELS) is necessary for evaluating the average electron–hole distance, i.e. the exciton size, in materials. Achieving accurate exciton size evaluations will promote the comprehension of optical functionality in materials such as photocatalysts. However, for amorphous materials, it is difficult to accurately derive ε(q, ω) because the elastic scattering intensity originating from the amorphous structure and the inelastic scattering intensity associated with elastic scattering overlap in the EELS spectrum. In this study, a method to remove these overlapping intensities from the EELS spectrum is proposed to accurately derive ε(q, ω) of an amorphous material. Amorphous SiO2 (am-SiO2) was subjected to AR-EELS measurements, and ε(q, ω) of am-SiO2 was derived after removing the intensity due to the amorphous structure using the proposed method. Thereafter, the exciton absorption intensity and the exciton size were evaluated. Applying the proposed method, the exciton absorption intensity was considerably suppressed in the q-region after 1.0 Å−1, where the elastic and inelastic scattering intensities originating from the amorphous structure are dominant. The exciton size evaluated was 2 nm ($ \pm $ 1 nm), consistent with the theoretically predicted size of ∼1 nm. Therefore, the proposed method is effective for deriving accurate ε(q, ω), facilitating exciton size evaluation for amorphous materials using AR-EELS.
- 4 February 2025
- Published by Oxford University Press (OUP) in Microscopy
- Vol. 74 (2) , 117-123
Open AccessDerivation method of the dielectric function of amorphous materials using angle-resolved electron energy loss spectroscopy for exciton size evaluation
Accurately deriving the momentum transfer dependence of the dielectric function ε(q, ω) using angle-resolved electron energy loss spectroscopy (AR-EELS) is necessary for evaluating the average electron–hole distance, i.e. the exciton size, in materials. Achieving accurate exciton size evaluations will promote the comprehension of optical functionality in materials such as photocatalysts. However, for amorphous materials, it is difficult to accurately derive ε(q, ω) because the elastic scattering intensity originating from the amorphous structure and the inelastic scattering intensity associated with elastic scattering overlap in the EELS spectrum. In this study, a method to remove these overlapping intensities from the EELS spectrum is proposed to accurately derive ε(q, ω) of an amorphous material. Amorphous SiO2 (am-SiO2) was subjected to AR-EELS measurements, and ε(q, ω) of am-SiO2 was derived after removing the intensity due to the amorphous structure using the proposed method. Thereafter, the exciton absorption intensity and the exciton size were evaluated. Applying the proposed method, the exciton absorption intensity was considerably suppressed in the q-region after 1.0 Å−1, where the elastic and inelastic scattering intensities originating from the amorphous structure are dominant. The exciton size evaluated was 2 nm ($ \pm $ 1 nm), consistent with the theoretically predicted size of ∼1 nm. Therefore, the proposed method is effective for deriving accurate ε(q, ω), facilitating exciton size evaluation for amorphous materials using AR-EELS.
- Open Access
- 24 January 2025
- Published by Oxford University Press (OUP) in Microscopy
- Vol. 74 (4) , 303-308
Self-absorption effect in soft X-ray emission spectra utilized for bandgap evaluation of semiconductors
The self-absorption effects observed in the background intensity just above the Si L-emission spectra of Si and β-Si3N4, and the C K-emission spectra of diamond and graphite were examined. Based on comparisons with reported results, the energy positions of absorption edges – representing the bottom of conduction bands (CBs) – were assigned. The self-absorption profiles in the background intensities were consistent with previously reported data. The simultaneous observation of valence band and CB edges allowed the determination of a bandgap energy of 1.1 eV for Si, which agrees with the indirect bandgap energy of Si. For β-Si3N4, the bandgap energy was evaluated as 5.1 eV. For diamond, the edge positions were matched with reported values, and the bandgap energy was calculated to be 5.0 eV, slightly smaller than the optical gap of 5.5 eV. These observations suggest that both edges can be expected for semiconductors in principle. On the other hand, C K-emission spectrum of graphite, a semimetal also showed an edge structure, which was assigned to the self-absorption edge due to the transitions from 1s to σ* antibonding state of sp2 bonding.
- 24 January 2025
- Published by Oxford University Press (OUP) in Microscopy
- Vol. 74 (4) , 303-308
Open AccessSelf-absorption effect in soft X-ray emission spectra utilized for bandgap evaluation of semiconductors
The self-absorption effects observed in the background intensity just above the Si L-emission spectra of Si and β-Si3N4, and the C K-emission spectra of diamond and graphite were examined. Based on comparisons with reported results, the energy positions of absorption edges – representing the bottom of conduction bands (CBs) – were assigned. The self-absorption profiles in the background intensities were consistent with previously reported data. The simultaneous observation of valence band and CB edges allowed the determination of a bandgap energy of 1.1 eV for Si, which agrees with the indirect bandgap energy of Si. For β-Si3N4, the bandgap energy was evaluated as 5.1 eV. For diamond, the edge positions were matched with reported values, and the bandgap energy was calculated to be 5.0 eV, slightly smaller than the optical gap of 5.5 eV. These observations suggest that both edges can be expected for semiconductors in principle. On the other hand, C K-emission spectrum of graphite, a semimetal also showed an edge structure, which was assigned to the self-absorption edge due to the transitions from 1s to σ* antibonding state of sp2 bonding.
- 1 December 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (12)
Design of soft x-ray high diffraction efficiency and spectral flux Au/Ni bilayer coated laminar-type diffraction grating for objective soft x-ray flat-field spectrograph in a region of 250–550 eV
An objective soft x-ray flat-field spectrograph employing a laminar-type bilayer coated, varied-line-spacing, spherical grating was designed to improve the detection limit and sensitivity of soft x-ray flat-field spectrographs in a region of 250–550 eV. As a design criterion, spectral flux, SF, [Hatano et al., Appl. Opt. 60, 4993–4999 (2021)], which is proportional to the amount of optical flux incident onto a detector and correlated with detection sensitivity, was used to be maximized. To enhance reflectivity with the coating design, Au/Ni bilayer coating was investigated to optimize the incidence angle and thickness of the Ni layer. This is based on the consideration that, in an energy region of over 400 eV, refractive indices of Au (bottom layer), Ni (top layer), and vacuum are increased from the bottom to the top of the layers, and a supplemental enhancement of reflectivity can be expected by optimizing the thickness of the top layer. Thus, the thickness of Ni and the incidence angle were chosen to be 8.0 nm and 86.00°, respectively. To maintain dispersion and spectral resolution of the grating used at an incidence angle of 87.07° as previously designed, groove density was increased to 1500 lines/mm from 1200 lines/mm of our previous design. Finally, a holographic, varied-line-spacing, spherical grating was designed assuming an aspherical-wavefront-recording configuration. The numerical simulation results showed that the spectrograph employing newly designed grating with laminar-type grooves and Au/Ni bilayer coating exhibited 2–18 times higher spectral flux as well as an improved spectral resolution compared with those obtained with the previously designed gratings and spectrographs.
- 1 December 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (12)
Design of soft x-ray high diffraction efficiency and spectral flux Au/Ni bilayer coated laminar-type diffraction grating for objective soft x-ray flat-field spectrograph in a region of 250–550 eV
An objective soft x-ray flat-field spectrograph employing a laminar-type bilayer coated, varied-line-spacing, spherical grating was designed to improve the detection limit and sensitivity of soft x-ray flat-field spectrographs in a region of 250–550 eV. As a design criterion, spectral flux, SF, [Hatano et al., Appl. Opt. 60, 4993–4999 (2021)], which is proportional to the amount of optical flux incident onto a detector and correlated with detection sensitivity, was used to be maximized. To enhance reflectivity with the coating design, Au/Ni bilayer coating was investigated to optimize the incidence angle and thickness of the Ni layer. This is based on the consideration that, in an energy region of over 400 eV, refractive indices of Au (bottom layer), Ni (top layer), and vacuum are increased from the bottom to the top of the layers, and a supplemental enhancement of reflectivity can be expected by optimizing the thickness of the top layer. Thus, the thickness of Ni and the incidence angle were chosen to be 8.0 nm and 86.00°, respectively. To maintain dispersion and spectral resolution of the grating used at an incidence angle of 87.07° as previously designed, groove density was increased to 1500 lines/mm from 1200 lines/mm of our previous design. Finally, a holographic, varied-line-spacing, spherical grating was designed assuming an aspherical-wavefront-recording configuration. The numerical simulation results showed that the spectrograph employing newly designed grating with laminar-type grooves and Au/Ni bilayer coating exhibited 2–18 times higher spectral flux as well as an improved spectral resolution compared with those obtained with the previously designed gratings and spectrographs.
- 16 October 2024
- Published by Oxford University Press (OUP) in Microscopy
Anisotropic electronic structure study of MgB2C2 using soft X-ray emission spectroscopy microscopes
The anisotropic electronic structure of MgB2C2 was studied using soft X-ray emission spectroscopy electron microscopes. MgB2C2 fragments were selected by examining C K-emission profiles. C and B K-emission and Mg L-emission spectra were obtained, revealing common and distinct structures that reflect the mixing of valence orbitals. Since the material is reported to have two-dimensional B-C honeycomb layers, the orientational dependence of these emission spectra was also examined. Experimental data were compared with theoretically calculated partial density of states of the valence bands of the material. The C K-emission profile showed an apparent orientational dependence, while the B K-emission exhibited minimal dependence. This difference originated from the different energy distributions of C-2pz and B-2pz components in the valence bands. The Mg L-emission intensity was very small, likely due to charge transfer from Mg atoms to B-N layers. The Mg L-emission profile showed a peak related to structures in C-K and B-K. An unexpected intensity was observed just above the valence bands, which also showed orientational dependence, possibly due to a small deviation from the ideal composition of Mg:B:C = 1:2:2.
- 16 October 2024
- Published by Oxford University Press (OUP) in Microscopy
Anisotropic electronic structure study of MgB2C2 using soft X-ray emission spectroscopy microscopes
The anisotropic electronic structure of MgB2C2 was studied using soft X-ray emission spectroscopy electron microscopes. MgB2C2 fragments were selected by examining C K-emission profiles. C and B K-emission and Mg L-emission spectra were obtained, revealing common and distinct structures that reflect the mixing of valence orbitals. Since the material is reported to have two-dimensional B-C honeycomb layers, the orientational dependence of these emission spectra was also examined. Experimental data were compared with theoretically calculated partial density of states of the valence bands of the material. The C K-emission profile showed an apparent orientational dependence, while the B K-emission exhibited minimal dependence. This difference originated from the different energy distributions of C-2pz and B-2pz components in the valence bands. The Mg L-emission intensity was very small, likely due to charge transfer from Mg atoms to B-N layers. The Mg L-emission profile showed a peak related to structures in C-K and B-K. An unexpected intensity was observed just above the valence bands, which also showed orientational dependence, possibly due to a small deviation from the ideal composition of Mg:B:C = 1:2:2.
- 1 July 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (7)
Soft x-ray high diffraction efficiency and spectral flux laminar-type W/B4C multilayer diffraction grating for 300–1000 eV
Multilayer diffraction gratings are designed to improve the detection limit and sensitivity of soft x-ray flat-field spectrographs in the region of 300–1000 eV, placing emphasis on Fe-L (705 eV), Cu-L (930 eV), and Zn-L (1012 eV) emissions. For this purpose, spectral flux was used as the performance index, which is proportional to the amount of optical flux incident into a detector and correlated with detection sensitivity. A super-mirror-type W/B4C multilayer coating [Koike et al., Rev.Sci. Instrum. 94, 045109 (2023)] was employed to improve diffraction efficiency in a wide energy region. The unique feature of the multilayer structure is that the average refractive index and the period length of W/B4C layer pairs are increased from the bottom to top layers. In addition, the incidence angle was reduced to 86.03° from 88.65° and the nominal groove density was increased to 3200 lines/mm from 2400 lines/mm of our previous design, to improve spectral flux while maintaining dispersion and spectral resolution. A holographic varied-line-spacing spherical grating and a soft x-ray flat-field spectrograph were designed, using the aspherical-wavefront-recording method, assuming the nominal grating constant and incident angle described above. The numerical simulation results showed that the spectrograph employing the newly designed grating with the W/B4C multilayer indicated 3.2–8.2 times higher spectral flux compared with those using the previously designed grating while keeping the same spectral resolution.
- 1 July 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (7)
Soft x-ray high diffraction efficiency and spectral flux laminar-type W/B4C multilayer diffraction grating for 300–1000 eV
Multilayer diffraction gratings are designed to improve the detection limit and sensitivity of soft x-ray flat-field spectrographs in the region of 300–1000 eV, placing emphasis on Fe-L (705 eV), Cu-L (930 eV), and Zn-L (1012 eV) emissions. For this purpose, spectral flux was used as the performance index, which is proportional to the amount of optical flux incident into a detector and correlated with detection sensitivity. A super-mirror-type W/B4C multilayer coating [Koike et al., Rev.Sci. Instrum. 94, 045109 (2023)] was employed to improve diffraction efficiency in a wide energy region. The unique feature of the multilayer structure is that the average refractive index and the period length of W/B4C layer pairs are increased from the bottom to top layers. In addition, the incidence angle was reduced to 86.03° from 88.65° and the nominal groove density was increased to 3200 lines/mm from 2400 lines/mm of our previous design, to improve spectral flux while maintaining dispersion and spectral resolution. A holographic varied-line-spacing spherical grating and a soft x-ray flat-field spectrograph were designed, using the aspherical-wavefront-recording method, assuming the nominal grating constant and incident angle described above. The numerical simulation results showed that the spectrograph employing the newly designed grating with the W/B4C multilayer indicated 3.2–8.2 times higher spectral flux compared with those using the previously designed grating while keeping the same spectral resolution.
- 5 March 2024
- Published by Oxford University Press (OUP) in Microscopy
- Vol. 73 (5) , 451-455
Simple derivation of L-absorption spectra of 3d transition metal elements by the self-absorption effect observed in soft X-ray emission spectra
This study proposes a simple evaluation method for deriving L-absorption information from two L-emission spectra of 3d transition metal (TM) elements obtained at two different accelerating voltages. This method realizes a spatial identity for X-ray emission and absorption spectroscopies. This method was evaluated for the Fe L-emission spectra of Fe and its oxides and was applied to the TM L-emission spectra of MnO, Co, CoO and NiO. The derived absorption peak positions were consistent with those obtained previously at synchrotron orbital radiation facilities, which considered the core–hole effect. This simple derivation method could be useful for obtaining X-ray absorption spectroscopy distribution images from X-ray emission spectroscopy mapping data obtained by scanning electron microscopy.
- 5 March 2024
- Published by Oxford University Press (OUP) in Microscopy
- Vol. 73 (5) , 451-455
Simple derivation of L-absorption spectra of 3d transition metal elements by the self-absorption effect observed in soft X-ray emission spectra
This study proposes a simple evaluation method for deriving L-absorption information from two L-emission spectra of 3d transition metal (TM) elements obtained at two different accelerating voltages. This method realizes a spatial identity for X-ray emission and absorption spectroscopies. This method was evaluated for the Fe L-emission spectra of Fe and its oxides and was applied to the TM L-emission spectra of MnO, Co, CoO and NiO. The derived absorption peak positions were consistent with those obtained previously at synchrotron orbital radiation facilities, which considered the core–hole effect. This simple derivation method could be useful for obtaining X-ray absorption spectroscopy distribution images from X-ray emission spectroscopy mapping data obtained by scanning electron microscopy.