Baekkyeong Ko
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Baekkyeong Ko has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Anyuan Chen
Department of Electrical Energy, Norwegian University of Science and Technology, Trondheim, Norway
1 shared publication - Arne Nysveen
Department of Electric Energy, Norwegian University of Science and Technology, Trondheim, Norway
1 shared publication - Byambasuren Battulga
Department of Electrical Engineering, Korea University, Seoul, Korea
1 shared publication - Hossein Ehya
Department of Electric Energy, Norwegian University of Science and Technology (NTNU), Trondheim, Norway
1 shared publication Kyeongyeol Kim
CFI Research Center, Korea Electric Power Corporation, Daejon, South Korea
1 shared publication- Muhammad Faizan Shaikh
Department of Electrical Engineering, Korea University, Seoul, South Korea
1 shared publication
Latest Publications
- 14 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Energy Conversion
- Vol. 40 (2) , 1686-1689
Sensitive Detection of Shorted Field Winding Turns in Salient Pole Synchronous Machines With High Frequency Pole Drop Test
The pole drop test is the most widely accepted test for detecting short circuits in the field winding of salient pole synchronous machines (SPSM). Although it is a simple and effective test, there are concerns on the reliability due to the inherent asymmetry between the poles, especially for cases where the percentage of shorted turns is low. Considering that this is the primary test used in industry for detecting shorted field turns in SPSMs, improving the sensitivity of the test is highly desirable for reliable fault detection. In this paper, it is shown that the sensitivity of the pole drop test can be significantly improved by increasing the excitation frequency of the test voltage above the 50/60 Hz currently used, which is not reported elsewhere. An electrical equivalent circuit analysis and an experimental study on a 4 pole, 30 kVA synchronous motor and a 14 pole, 100 kVA hydrogenator prototype are given to verify the claims made.
- 14 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Energy Conversion
- Vol. 40 (2) , 1686-1689
Sensitive Detection of Shorted Field Winding Turns in Salient Pole Synchronous Machines With High Frequency Pole Drop Test
The pole drop test is the most widely accepted test for detecting short circuits in the field winding of salient pole synchronous machines (SPSM). Although it is a simple and effective test, there are concerns on the reliability due to the inherent asymmetry between the poles, especially for cases where the percentage of shorted turns is low. Considering that this is the primary test used in industry for detecting shorted field turns in SPSMs, improving the sensitivity of the test is highly desirable for reliable fault detection. In this paper, it is shown that the sensitivity of the pole drop test can be significantly improved by increasing the excitation frequency of the test voltage above the 50/60 Hz currently used, which is not reported elsewhere. An electrical equivalent circuit analysis and an experimental study on a 4 pole, 30 kVA synchronous motor and a 14 pole, 100 kVA hydrogenator prototype are given to verify the claims made.