Philip R. Dolan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Philip R. Dolan has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
- Christopher J. Chunnilall
National Physical Laboratory, Teddington, U.K.
3 shared publications - Luke Arabskyj
National Physical Laboratory 1 , Hampton Road, Teddington TW11 0LW
3 shared publications - Ted Silva Santana
National Physical Laboratory 1 , Hampton Road, Teddington TW11 0LW
3 shared publications - Benyam Dejen
National Physical Laboratory 1 , Hampton Road, Teddington TW11 0LW
2 shared publications - Marco Lucamarini
University of York
2 shared publications - A. Vaquero-Stainer
National Physical Laboratory 1 , Hampton Road, Teddington TW11 0LW
1 shared publication
Latest Publications
- Open Access
- 4 June 2025
- Published by Optica Publishing Group in Optics Express
- Vol. 33 (12) , 25159-25169
Nitrogen-vacancy color centers in nanodiamonds as reference single-photon emitters
Quantitative and reproducible optical characterization of single quantum emitters is crucial for quantum photonic materials research, yet accounting for measurement conditions remains challenging due to a lack of an established reference standard. We propose nanodiamonds containing single nitrogen vacancy (NV?) color centers as reliable, stable, and robust reference sources of single-photon emission. We select 4 potential reference emitter candidates from a study of thousands of NV?centers. Candidates were remeasured at a second laboratory, correlating optical pump power and NV?center emission intensity at saturation in addition to corresponding g(2)(0) values. A reference nanodiamond is demonstrated to account for experimental conditions, with reproducible and reliable single-photon emission, as a model for a new, to our knowledge, single-photon emitter reference standard.
- 4 June 2025
- Published by Optica Publishing Group in Optics Express
- Vol. 33 (12) , 25159-25169
Open AccessNitrogen-vacancy color centers in nanodiamonds as reference single-photon emitters
Quantitative and reproducible optical characterization of single quantum emitters is crucial for quantum photonic materials research, yet accounting for measurement conditions remains challenging due to a lack of an established reference standard. We propose nanodiamonds containing single nitrogen vacancy (NV?) color centers as reliable, stable, and robust reference sources of single-photon emission. We select 4 potential reference emitter candidates from a study of thousands of NV?centers. Candidates were remeasured at a second laboratory, correlating optical pump power and NV?center emission intensity at saturation in addition to corresponding g(2)(0) values. A reference nanodiamond is demonstrated to account for experimental conditions, with reproducible and reliable single-photon emission, as a model for a new, to our knowledge, single-photon emitter reference standard.
- Open Access
- 18 December 2024
- Published by American Physical Society (APS) in Physical Review Applied
- Vol. 22 (6)
Measuring photon correlation using imperfect detectors
Single-photon detectors are “blind” after the detection of a photon, and thereafter display a characteristic recovery in efficiency, during which the number of undetected photons depends on the statistics of the incident light. We show how the efficiency recovery, photon statistics, and intensity have an interdependent relationship which suppresses a detector’s ability to count photons and measure correlations. We also demonstrate this effect with an experiment using n such detectors to determine the n th -order correlation function with pseudothermal light. Published by the American Physical Society 2024
- 18 December 2024
- Published by American Physical Society (APS) in Physical Review Applied
- Vol. 22 (6)
Open AccessMeasuring photon correlation using imperfect detectors
Single-photon detectors are “blind” after the detection of a photon, and thereafter display a characteristic recovery in efficiency, during which the number of undetected photons depends on the statistics of the incident light. We show how the efficiency recovery, photon statistics, and intensity have an interdependent relationship which suppresses a detector’s ability to count photons and measure correlations. We also demonstrate this effect with an experiment using n such detectors to determine the n th -order correlation function with pseudothermal light. Published by the American Physical Society 2024
- Open Access
- 4 November 2024
- Published by AIP Publishing in Applied Physics Letters
- Vol. 125 (19)
Interference effects in commercially available free-space silicon single-photon avalanche diodes
Single-photon avalanche diodes (SPADs) are essential for photon-based measurements and metrology, enabling measurement comparisons at the few-photon level and facilitating global traceability to the SI. A spatially uniform detector response is crucial for these applications. Here, we report on interference effects in commercially available silicon SPADs that are detrimental to their spatial uniformity. Contrasts as high as 18% are observed, posing problems for metrology and general applications that utilize coherent light and require stable detection efficiencies. We eliminate the device optical window as a contributing interface, isolating likely causes to anti-reflective coatings, the semiconductor surface, and the SPAD's internal structure. We also present results where we leverage this sub-optimal behavior by aligning an incident beam with the position of maximum constructive interference, yielding an effective detection efficiency of 51.1(1.7)% compared to the normal value of 44.3(1)% obtained with the interference suppressed. We anticipate that this work will significantly impact the continuing development of these devices, the methods for characterizing them, and their use in accurate measurements.
- 4 November 2024
- Published by AIP Publishing in Applied Physics Letters
- Vol. 125 (19)
Open AccessInterference effects in commercially available free-space silicon single-photon avalanche diodes
Single-photon avalanche diodes (SPADs) are essential for photon-based measurements and metrology, enabling measurement comparisons at the few-photon level and facilitating global traceability to the SI. A spatially uniform detector response is crucial for these applications. Here, we report on interference effects in commercially available silicon SPADs that are detrimental to their spatial uniformity. Contrasts as high as 18% are observed, posing problems for metrology and general applications that utilize coherent light and require stable detection efficiencies. We eliminate the device optical window as a contributing interface, isolating likely causes to anti-reflective coatings, the semiconductor surface, and the SPAD's internal structure. We also present results where we leverage this sub-optimal behavior by aligning an incident beam with the position of maximum constructive interference, yielding an effective detection efficiency of 51.1(1.7)% compared to the normal value of 44.3(1)% obtained with the interference suppressed. We anticipate that this work will significantly impact the continuing development of these devices, the methods for characterizing them, and their use in accurate measurements.
- Open Access
- 4 November 2024
- Published by AIP Publishing in Applied Physics Letters
- Vol. 125 (19)
A refined method for characterizing afterpulse probability in single-photon avalanche diodes
Single-photon avalanche diodes (SPADs) are critical components in low-light-level sensing and photonic quantum information applications. For these, it is often necessary that a full characterization of the SPAD is performed, for which a key metric is the afterpulse probability. This study provides a detailed comparison of the common synchronized and non-synchronized methods used to measure afterpulse probability. Measurements on a single SPAD reveal inconsistencies between the afterpulse probabilities obtained by the two methods. By re-deriving the equations from first principles, the discrepancy is traced to the analysis approach for the non-synchronized experiment. An improved analysis approach is presented, leading to better agreement between the non-synchronized and synchronized methods. The study also provides guidance on the experimental conditions required for the valid application of both methods, along with a detailed analysis of the limitations of the non-synchronized method under high photon flux. These findings offer a more accurate approach for characterizing afterpulse probability and for reconciling the results of two methods, which enables better quantification of SPAD performance.
- 4 November 2024
- Published by AIP Publishing in Applied Physics Letters
- Vol. 125 (19)
Open AccessA refined method for characterizing afterpulse probability in single-photon avalanche diodes
Single-photon avalanche diodes (SPADs) are critical components in low-light-level sensing and photonic quantum information applications. For these, it is often necessary that a full characterization of the SPAD is performed, for which a key metric is the afterpulse probability. This study provides a detailed comparison of the common synchronized and non-synchronized methods used to measure afterpulse probability. Measurements on a single SPAD reveal inconsistencies between the afterpulse probabilities obtained by the two methods. By re-deriving the equations from first principles, the discrepancy is traced to the analysis approach for the non-synchronized experiment. An improved analysis approach is presented, leading to better agreement between the non-synchronized and synchronized methods. The study also provides guidance on the experimental conditions required for the valid application of both methods, along with a detailed analysis of the limitations of the non-synchronized method under high photon flux. These findings offer a more accurate approach for characterizing afterpulse probability and for reconciling the results of two methods, which enables better quantification of SPAD performance.
- Open Access
- 9 September 2024
- Published by IOP Publishing in Metrologia
- Vol. 61 (5) , 055008
Traceable characterisation of fibre-coupled single-photon detectors
The detection of single photons plays an essential role in advancing single-photon science and technologies. Yet, within the visible/near-infrared spectral region, accurate fibre-based optical power measurements at the few-photon level are not yet well-established. In this study, we report on a fibre-based setup, enabling traceable optical power measurements at the few-photon level in this spectral region. The setup was used to calibrate the detection efficiency (DE) of four single-photon avalanche diode (SPAD) detectors. The relative standard uncertainties on the mean DE values obtained from repeat fibre-to-detector couplings ranged from 0.67% to 0.81% (k = 2). However, the relative standard deviation of DE values, which ranged from 1.38% to 3.20% (k = 2), poses a challenge for the metrology of these devices and applications that require high accuracy and repeatability. We investigated the source of these variations by spatially mapping the response of a detector’s fibre connector port, using a focused free-space beam, allowing us to estimate the detector’s spatial non-uniformity. In addition, we realise a novel calibration approach for fibre-coupled SPADs in a free-space configuration, enabling a direct comparison between the fibre-based setup and the National Physical Laboratory’s established free-space facility using a single SPAD. Finally, we investigated alternative coupling methods, testing the repeatability of different fibre-to-fibre connectors in addition to direct fibre-to-detector couplings: SPADs from three manufacturers were tested, with both single-mode and multi-mode fibre.
- 9 September 2024
- Published by IOP Publishing in Metrologia
- Vol. 61 (5) , 055008
Open AccessTraceable characterisation of fibre-coupled single-photon detectors
The detection of single photons plays an essential role in advancing single-photon science and technologies. Yet, within the visible/near-infrared spectral region, accurate fibre-based optical power measurements at the few-photon level are not yet well-established. In this study, we report on a fibre-based setup, enabling traceable optical power measurements at the few-photon level in this spectral region. The setup was used to calibrate the detection efficiency (DE) of four single-photon avalanche diode (SPAD) detectors. The relative standard uncertainties on the mean DE values obtained from repeat fibre-to-detector couplings ranged from 0.67% to 0.81% (k = 2). However, the relative standard deviation of DE values, which ranged from 1.38% to 3.20% (k = 2), poses a challenge for the metrology of these devices and applications that require high accuracy and repeatability. We investigated the source of these variations by spatially mapping the response of a detector’s fibre connector port, using a focused free-space beam, allowing us to estimate the detector’s spatial non-uniformity. In addition, we realise a novel calibration approach for fibre-coupled SPADs in a free-space configuration, enabling a direct comparison between the fibre-based setup and the National Physical Laboratory’s established free-space facility using a single SPAD. Finally, we investigated alternative coupling methods, testing the repeatability of different fibre-to-fibre connectors in addition to direct fibre-to-detector couplings: SPADs from three manufacturers were tested, with both single-mode and multi-mode fibre.