Wenbo Zhou
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Wenbo Zhou has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Bo Zhou
College of Automation Engineering, Nanjing University of Aeronautics and Astronautics, Nanjing, China
2 shared publications - Yijun Zhang
School of Electrical and Information Engineering, Zhengzhou University, Zhengzhou, China
2 shared publications - Siyuan Jiang
School of Electrical Engineering and Automation, Henan Polytechnic University, Jiaozuo, China
1 shared publication - Tong Mei
Jiangsu Key Laboratory of New Energy Generation, Colleague of Automation, Nanjing University of Aeronautics and Astronautics, Nanjing, China
1 shared publication - Wenjing Fang
School of Electronics, Electrical Engineering, and Control, Qilu University of Technology, Jinan, China
1 shared publication - Yi Lu
College of Information Science and Technology Artificial Intelligence, Nanjing Forestry University, Nanjing, China
1 shared publication
Latest Publications
- 12 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 73 (5) , 6722-6733
An Open-Circuit Fault Diagnosis Method for H-Bridge Semi-Controlled Rectifier in DSEG System Based on Bus Current and Forward Freewheeling Diode Current
Fault diagnosis is a key technology to improve the reliability of electrical machine systems. However, no previous research has addressed open-circuit (OC) faults in the power switches of doubly salient electromagnetic generator (DSEG) systems with H-bridge semi-controlled rectifier (HBSCR), and the existing methods cannot be applied to these systems. To solve the problem, this article proposes an OC fault diagnosis method for power switches based on bus current and forward freewheeling diode current. Fault location is achieved by detecting the direction of the bus current and the forward freewheeling diode current before and after the switch-off angle, and analyzing relationships between them. The proposed method does not change the rectifier topology and has low diagnosis cost. It is independent of the fault position and operating conditions. Meanwhile, it can locate OC faults of single switch and dual switches in one sector at the same or different moments. Finally, experiments on a 12/8-pole DSEG platform validate the effectiveness of the proposed method.
- 12 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 73 (5) , 6722-6733
An Open-Circuit Fault Diagnosis Method for H-Bridge Semi-Controlled Rectifier in DSEG System Based on Bus Current and Forward Freewheeling Diode Current
Fault diagnosis is a key technology to improve the reliability of electrical machine systems. However, no previous research has addressed open-circuit (OC) faults in the power switches of doubly salient electromagnetic generator (DSEG) systems with H-bridge semi-controlled rectifier (HBSCR), and the existing methods cannot be applied to these systems. To solve the problem, this article proposes an OC fault diagnosis method for power switches based on bus current and forward freewheeling diode current. Fault location is achieved by detecting the direction of the bus current and the forward freewheeling diode current before and after the switch-off angle, and analyzing relationships between them. The proposed method does not change the rectifier topology and has low diagnosis cost. It is independent of the fault position and operating conditions. Meanwhile, it can locate OC faults of single switch and dual switches in one sector at the same or different moments. Finally, experiments on a 12/8-pole DSEG platform validate the effectiveness of the proposed method.
- 19 November 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 72 (6) , 5646-5657
Research on Gain Fault Diagnosis of Current Sensor for Doubly Salient Electromagnetic Motor at Standstill
Fault diagnosis of current sensor is the key technology to improve the reliability of doubly salient electromagnetic motor (DSEM) drive system. In some occasions, such as initial position estimation of position sensorless, the motor is at standstill. However, there is no method addressing the fault diagnosis of current sensor for DSEM at standstill. To solve this problem, three methods are proposed to realize gain fault diagnosis of current sensor for DSEM at standstill in this article. One method is realized by detecting excitation current during excitation field building, and the other two are realized by detecting phase currents during the injection of specific current pulses. Then, there is a comparison of three fault diagnosis methods. The proposed method does not require the values of motor parameters, and it can be used either as part of an initial debugging or periodic testing of the system, which can also improve the reliability of initial position estimation to avoid startup failure of motor. Finally, the experimental results validate the effectiveness of the proposed method.
- 19 November 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 72 (6) , 5646-5657
Research on Gain Fault Diagnosis of Current Sensor for Doubly Salient Electromagnetic Motor at Standstill
Fault diagnosis of current sensor is the key technology to improve the reliability of doubly salient electromagnetic motor (DSEM) drive system. In some occasions, such as initial position estimation of position sensorless, the motor is at standstill. However, there is no method addressing the fault diagnosis of current sensor for DSEM at standstill. To solve this problem, three methods are proposed to realize gain fault diagnosis of current sensor for DSEM at standstill in this article. One method is realized by detecting excitation current during excitation field building, and the other two are realized by detecting phase currents during the injection of specific current pulses. Then, there is a comparison of three fault diagnosis methods. The proposed method does not require the values of motor parameters, and it can be used either as part of an initial debugging or periodic testing of the system, which can also improve the reliability of initial position estimation to avoid startup failure of motor. Finally, the experimental results validate the effectiveness of the proposed method.