KBKevin Beckford

Kevin Beckford

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Kevin Beckford has a total of 7 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Miniature 3D-printed rod-like refractive objective for endoscopic applications

    by Kevin Beckford, Yicheng Ma, Jinyun Liu, Tomasz S. Tkaczyk

    SignificanceThe three-dimensional (3D)-printed refractive rod objective for endoscopy preserves the compact, gradient index (GRIN)-like format while delivering a wide field of view (FOV) comparable to its diameter and larger than that of a commercial GRIN lens.AimWe focus on the design, fabrication, and experimental validation of a proof-of-concept refractive rod objective for fluorescence imaging of mouse colon tissue, with performance compared with a commercial GRIN lens.ApproachA 1× magnification refractive rod-like objective was designed in Zemax OpticStudio and fabricated using two-photon polymerization additive manufacturing. The objective consists of a sequence of convex refractive surfaces printed in contact at their vertices, with refractive index contrast provided by partially or non-polymerized resin contained within an enclosing wall. The lens has a diameter of 500 μm with a clear aperture of 470 μm, a total length of 2.06 mm, and a working distance of 1.6 mm and was optimized for a numerical aperture of 0.075 and a 500-μm design field at 525-nm light. Three photopolymer resins (IP-S, IP-Visio, and IPX-Clear) were evaluated through excitation–emission matrix measurements to assess autofluorescence. By imaging group 7, element 6 of a 1951 United States Air Force (USAF) resolution target, the field was assessed by plot profile and modulation transfer function measurements.ResultsThe fabricated objective resolved group 7, element 6 of a USAF resolution target (4.38 μm), closely matching the theoretical diffraction-limited resolution of 4.27 μm. Compared with a commercial 600-μm-diameter GRIN lens, the 3D-printed objective achieved a substantially larger FOV (498 versus 188 μm). Spectral characterization showed that IP-Visio exhibited the lowest autofluorescence under 455-nm excitation when unpolymerized resin was present. Using an IP-Visio objective, fluorescence images of proflavine-stained mouse colon tissue were successfully acquired.ConclusionsThe demonstrated refractive rod-like objective combines the compact geometry of a GRIN lens with the aberration correction capability of multi-element refractive optics, enabling uniform resolution across a large FOV. The approach also allows material selection tailored to fluorescence imaging requirements. Future work will focus on integration with fiber bundles and on fully polymerized designs with spatially tuned refractive index for improved long-term stability.


  • Open Access

    Flexible catheter optical coherence tomography of the porcine middle ear via the Eustachian tube using a 3D-printed reflective objective

    by Clayton B. Walker, Kevin Beckford, Zihan Yang, Jinyun Liu, Wihan Kim, Tomasz S. Tkaczyk, Brian E. Applegate

    SignificanceCholesteatomas, benign tumors that grow in the middle ear, can lead to conductive hearing loss. If not completely removed during surgery, these tumors may regrow. Current imaging technologies struggle to detect residual tumors noninvasively due to limitations in contrast and resolution, often necessitating additional surgery for inspection. To address this, we developed a catheter endoscope capable of being inserted through the Eustachian tube, allowing detailed examination of the middle ear without surgery. Using two-photon polymerization (2PP) technology, we fabricated miniature, side-viewing reflective endoscope objectives. This approach enabled the rapid production of single-element objectives with highly repeatable optical properties, easily adaptable to specific imaging needs.AimWe aim to design, fabricate, and demonstrate a catheter endoscope for optical coherence tomography (OCT) endoscopy of the middle ear via the Eustachian tube.ApproachSide-viewing, reflective lenses were designed in OpticStudio and 3D printed using 2PP followed by sputter coating with gold. Standard metrology techniques were used to verify and optimize the objective’s shape. The optical performance of the catheter endoscopes was measured with a beam profiler. Finally, OCT imaging of the middle ear of a pig via the Eustachian tube was completed using the fully assembled catheter endoscope.ResultsMetrology showed the printed lenses conformed closely to the design. The catheter endoscope’s FWHM spot size had a mean ± standard deviation of 25.3±1.8 μm with a measured working distance of 1.960±0.057 mm. Volumetric OCT images of the middle ear, inner ear, and Eustachian tube were captured in a postmortem pig head using the catheter endoscope.ConclusionsThe 2PP approach is fast and highly repeatable for miniature reflective objective fabrication. OCT catheter endoscopy via the Eustachian tube enabled imaging of the middle ear, Eustachian tube, and surprisingly part of the inner ear.