Abdulrahman M. Alzahrani
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Abdulrahman M. Alzahrani has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Abdulrahman Alaskar
Department of Chemistry, National Measurement and Calibration Center, Saudi Standards, Metrology and Quality Organization (SASO), Riyadh 11471, Kingdom of Saudi Arabia
2 shared publications - Adel Shehata
Department of Chemistry, National Measurement and Calibration Center, Saudi Standards, Metrology and Quality Organization (SASO), Riyadh 11471, Kingdom of Saudi Arabia
2 shared publications - Fahad A. Alkharraa
Department of Chemistry, National Measurement and Calibration Center (NMCC), Saudi Standards, Metrology and Quality Organization (SASO), Riyadh, Kingdom of Saudi Arabia
2 shared publications - Mohammed A. Alrasheed
Department of Chemistry, National Measurement and Calibration Center (NMCC), Saudi Standards, Metrology and Quality Organization (SASO), Riyadh, Kingdom of Saudi Arabia
2 shared publications - Abdullah Alosaimi
Saudi Standards, Metrology and Quality Org./National Measurement and Calibration Center (SASO/NMCC)
1 shared publication - Sowailem A. Alsowailem
Department of Chemistry, National Measurement and Calibration Center (NMCC), Saudi Standards, Metrology and Quality Organization (SASO), Riyadh, Kingdom of Saudi Arabia
1 shared publication
Latest Publications
- Open Access
- 30 September 2025
- Published by Asian Publication Corporation in Asian Journal of Chemistry
- Vol. 37 (10) , 2500-2506
Development and Validation of a GC-ECD Method for the Determination of Trifluralin in Acetonitrile with Uncertainty Estimation
The use of trifluralin herbicide has raised concerns due to its persistence in the environment and potential toxicological impacts on human health and ecosystems. The aim of this study was to develop and validate a simple and reliable method for determining trifluralin residues in acetonitrile using gas chromatography with an electron capture detector (GC-ECD). The method was developed using internal standard calibration and validated in accordance with international guidelines. Validation parameters included LOD, LOQ, selectivity, linearity, precision, accuracy (recovery and bias) and measurement uncertainty. The method demonstrated high selectivity with no interfering peaks at the trifluralin retention time. A strong linear relationship was observed in the concentration range of 4-11 µg/g with a correlation coefficient (R2) of 0.9996. The precision, expressed as relative standard deviation (%RSD) was found 3.84% across all levels. Recovery values ranged from 98.45% to 100.06%, with % bias between 0.06% and 1.55% confirming the method accuracy. The expanded uncertainty was estimated to be 9.86% primarily influenced by sample and internal standard (IS) peak areas. The validated GC-ECD method provides a reliable, precise and accurate approach for quantifying trifluralin residues in environmental and food samples. It is suitable for routine monitoring, regulatory applications and risk assessments in agricultural and environmental contexts.
- 30 September 2025
- Published by Asian Publication Corporation in Asian Journal of Chemistry
- Vol. 37 (10) , 2500-2506
Open AccessDevelopment and Validation of a GC-ECD Method for the Determination of Trifluralin in Acetonitrile with Uncertainty Estimation
The use of trifluralin herbicide has raised concerns due to its persistence in the environment and potential toxicological impacts on human health and ecosystems. The aim of this study was to develop and validate a simple and reliable method for determining trifluralin residues in acetonitrile using gas chromatography with an electron capture detector (GC-ECD). The method was developed using internal standard calibration and validated in accordance with international guidelines. Validation parameters included LOD, LOQ, selectivity, linearity, precision, accuracy (recovery and bias) and measurement uncertainty. The method demonstrated high selectivity with no interfering peaks at the trifluralin retention time. A strong linear relationship was observed in the concentration range of 4-11 µg/g with a correlation coefficient (R2) of 0.9996. The precision, expressed as relative standard deviation (%RSD) was found 3.84% across all levels. Recovery values ranged from 98.45% to 100.06%, with % bias between 0.06% and 1.55% confirming the method accuracy. The expanded uncertainty was estimated to be 9.86% primarily influenced by sample and internal standard (IS) peak areas. The validated GC-ECD method provides a reliable, precise and accurate approach for quantifying trifluralin residues in environmental and food samples. It is suitable for routine monitoring, regulatory applications and risk assessments in agricultural and environmental contexts.
- 1 December 2020
- Published by ACG Publications in Journal of Chemical Metrology
- Vol. 14 (2) , 88-105
Certification of sodium benzoate solution reference material by HPLC-UV, LC-MS/MS and UV-VIS-NIR spectrophotometry for food and drug analysis
Sodium benzoate is one of the most widely used food perseverates and has to be used in regulated amounts to avoid its harmful health effects. Reviewing the scientific literature for traceability of the analytical measurement results of sodium benzoate in various food and drug applications to the SI units, it has been found that no scientific details of certification of sodium benzoate CRMs used for the calibration of measuring equipment are published. For this reason, the national metrology institute of Saudi Arabia (SASO/NMCC) certifies a sodium benzoate solution reference material. In this work, sodium benzoate was synthesized, purified and a batch solution reference material was prepared as 1014.47 mg/kg then homogenized and bottled. Homogeneity and stability of the candidate RM were assessed and the results obtained showed that the material is sufficiently homogeneous and stable. Characterization of the reference material was carried out by HPLC-UV, LC-MS/MS and UV-VIS-NIR spectrophotometer as three independent methods. The certified value was derived by combining data from the three methods using the weighted mean approach and was found 1016.13 mg/kg. The certified uncertainty was calculated as weighted uncertainty and was found 10.47 mg/kg (1.03%). Sources of this uncertainty were identified from the characterization, uchar, homogeneity, uhom, and long-term stability, ults, as well as the bias allowance, B.
- 1 December 2020
- Published by ACG Publications in Journal of Chemical Metrology
- Vol. 14 (2) , 88-105
Certification of sodium benzoate solution reference material by HPLC-UV, LC-MS/MS and UV-VIS-NIR spectrophotometry for food and drug analysis
Sodium benzoate is one of the most widely used food perseverates and has to be used in regulated amounts to avoid its harmful health effects. Reviewing the scientific literature for traceability of the analytical measurement results of sodium benzoate in various food and drug applications to the SI units, it has been found that no scientific details of certification of sodium benzoate CRMs used for the calibration of measuring equipment are published. For this reason, the national metrology institute of Saudi Arabia (SASO/NMCC) certifies a sodium benzoate solution reference material. In this work, sodium benzoate was synthesized, purified and a batch solution reference material was prepared as 1014.47 mg/kg then homogenized and bottled. Homogeneity and stability of the candidate RM were assessed and the results obtained showed that the material is sufficiently homogeneous and stable. Characterization of the reference material was carried out by HPLC-UV, LC-MS/MS and UV-VIS-NIR spectrophotometer as three independent methods. The certified value was derived by combining data from the three methods using the weighted mean approach and was found 1016.13 mg/kg. The certified uncertainty was calculated as weighted uncertainty and was found 10.47 mg/kg (1.03%). Sources of this uncertainty were identified from the characterization, uchar, homogeneity, uhom, and long-term stability, ults, as well as the bias allowance, B.