Sowailem A. Alsowailem
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Sowailem A. Alsowailem has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Abdulrahman Alaskar
Department of Chemistry, National Measurement and Calibration Center, Saudi Standards, Metrology and Quality Organization (SASO), Riyadh 11471, Kingdom of Saudi Arabia
1 shared publication - Abdulrahman M. Alzahrani
Department of Chemistry, National Measurement and Calibration Center (NMCC), Saudi Standards, Metrology and Quality Organization (SASO), Riyadh, Kingdom of Saudi Arabia
1 shared publication - Adel Shehata
Department of Chemistry, National Measurement and Calibration Center, Saudi Standards, Metrology and Quality Organization (SASO), Riyadh 11471, Kingdom of Saudi Arabia
1 shared publication - Fahad A. Alkharraa
Department of Chemistry, National Measurement and Calibration Center (NMCC), Saudi Standards, Metrology and Quality Organization (SASO), Riyadh, Kingdom of Saudi Arabia
1 shared publication - Mohammed A. Alrasheed
Department of Chemistry, National Measurement and Calibration Center (NMCC), Saudi Standards, Metrology and Quality Organization (SASO), Riyadh, Kingdom of Saudi Arabia
1 shared publication
Latest Publications
- Open Access
- 30 September 2025
- Published by Asian Publication Corporation in Asian Journal of Chemistry
- Vol. 37 (10) , 2500-2506
Development and Validation of a GC-ECD Method for the Determination of Trifluralin in Acetonitrile with Uncertainty Estimation
The use of trifluralin herbicide has raised concerns due to its persistence in the environment and potential toxicological impacts on human health and ecosystems. The aim of this study was to develop and validate a simple and reliable method for determining trifluralin residues in acetonitrile using gas chromatography with an electron capture detector (GC-ECD). The method was developed using internal standard calibration and validated in accordance with international guidelines. Validation parameters included LOD, LOQ, selectivity, linearity, precision, accuracy (recovery and bias) and measurement uncertainty. The method demonstrated high selectivity with no interfering peaks at the trifluralin retention time. A strong linear relationship was observed in the concentration range of 4-11 µg/g with a correlation coefficient (R2) of 0.9996. The precision, expressed as relative standard deviation (%RSD) was found 3.84% across all levels. Recovery values ranged from 98.45% to 100.06%, with % bias between 0.06% and 1.55% confirming the method accuracy. The expanded uncertainty was estimated to be 9.86% primarily influenced by sample and internal standard (IS) peak areas. The validated GC-ECD method provides a reliable, precise and accurate approach for quantifying trifluralin residues in environmental and food samples. It is suitable for routine monitoring, regulatory applications and risk assessments in agricultural and environmental contexts.
- 30 September 2025
- Published by Asian Publication Corporation in Asian Journal of Chemistry
- Vol. 37 (10) , 2500-2506
Open AccessDevelopment and Validation of a GC-ECD Method for the Determination of Trifluralin in Acetonitrile with Uncertainty Estimation
The use of trifluralin herbicide has raised concerns due to its persistence in the environment and potential toxicological impacts on human health and ecosystems. The aim of this study was to develop and validate a simple and reliable method for determining trifluralin residues in acetonitrile using gas chromatography with an electron capture detector (GC-ECD). The method was developed using internal standard calibration and validated in accordance with international guidelines. Validation parameters included LOD, LOQ, selectivity, linearity, precision, accuracy (recovery and bias) and measurement uncertainty. The method demonstrated high selectivity with no interfering peaks at the trifluralin retention time. A strong linear relationship was observed in the concentration range of 4-11 µg/g with a correlation coefficient (R2) of 0.9996. The precision, expressed as relative standard deviation (%RSD) was found 3.84% across all levels. Recovery values ranged from 98.45% to 100.06%, with % bias between 0.06% and 1.55% confirming the method accuracy. The expanded uncertainty was estimated to be 9.86% primarily influenced by sample and internal standard (IS) peak areas. The validated GC-ECD method provides a reliable, precise and accurate approach for quantifying trifluralin residues in environmental and food samples. It is suitable for routine monitoring, regulatory applications and risk assessments in agricultural and environmental contexts.