Abdulrahman Alaskar
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Abdulrahman Alaskar has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Adel Shehata
Department of Chemistry, National Measurement and Calibration Center, Saudi Standards, Metrology and Quality Organization (SASO), Riyadh 11471, Kingdom of Saudi Arabia
6 shared publications - Abdullah S. AlOwaysi
Department of Chemistry, National Measurement and Calibration Center, Saudi Standards, Metrology and Quality Organization (SASO), Riyadh 11471, Kingdom of Saudi Arabia
2 shared publications - Abdulrahman M. Alzahrani
Department of Chemistry, National Measurement and Calibration Center (NMCC), Saudi Standards, Metrology and Quality Organization (SASO), Riyadh, Kingdom of Saudi Arabia
2 shared publications - Fahad A. Alkharraa
Department of Chemistry, National Measurement and Calibration Center (NMCC), Saudi Standards, Metrology and Quality Organization (SASO), Riyadh, Kingdom of Saudi Arabia
2 shared publications - Fahad R. Almutairi
Saudi Standards, Metrology and Quality Organization
2 shared publications - Mohammed A. Alrasheed
Department of Chemistry, National Measurement and Calibration Center (NMCC), Saudi Standards, Metrology and Quality Organization (SASO), Riyadh, Kingdom of Saudi Arabia
2 shared publications
Latest Publications
- Open Access
- 9 October 2026
- Published by Asian Publication Corporation in Asian Journal of Chemistry
- Vol. 38 (10) , 2559-2566
Preparation and Certification of Propane in Nitrogen as Reference Material for Ensuring Traceability of Hydrocarbon Emission Measurements
Propane in nitrogen (C3H8/N2) gas mixtures are widely used as calibration standards for hydrocarbon measurements in environmental monitoring, energy production and industrial process control. Five C3H8/N2 gas mixtures, covering the range of 804.8148-12053.8148 µmol/mol, were gravimetrically prepared according to ISO 6142 using a two-step dilution approach with high-purity propane and nitrogen. The prepared mixtures were validated by gas chromatography with flame ionization detection (GC-FID) in accordance with ISO 6143. The GC-FID results showed good agreement with the gravimetric values, confirming the validity of the preparation method. The certified values determined by gravimetry were established for 4 mixtures (B, C, D, E) as 12053.81 ± 97.49, 9013.23 ± 78.11, 5998.011 ± 57.72 and 2987.29 ± 66.91 µmol/mol, respectively. The mole fraction of the mixture F, 804.81 ± 35.97 µmol/mol was considered an information value since it was associated with large uncertainty of 7.016%. The performance of the produced certified reference materials (CRMs) was checked by using them to calibrate the GC-FID, then measure a CRM sample of 8010 µmol/mol as an unknown. The precision (%RSD) and accuracy of the measured results were found to be 0.12% and 99.75%, respectively. These results confirm that the prepared C3H8/N2 mixtures meet the criteria for certified reference materials and are suitable as calibrants for hydrocarbon emission measurement instruments in industrial gas analysis and environmental monitoring.
- 9 October 2026
- Published by Asian Publication Corporation in Asian Journal of Chemistry
- Vol. 38 (10) , 2559-2566
Open AccessPreparation and Certification of Propane in Nitrogen as Reference Material for Ensuring Traceability of Hydrocarbon Emission Measurements
Propane in nitrogen (C3H8/N2) gas mixtures are widely used as calibration standards for hydrocarbon measurements in environmental monitoring, energy production and industrial process control. Five C3H8/N2 gas mixtures, covering the range of 804.8148-12053.8148 µmol/mol, were gravimetrically prepared according to ISO 6142 using a two-step dilution approach with high-purity propane and nitrogen. The prepared mixtures were validated by gas chromatography with flame ionization detection (GC-FID) in accordance with ISO 6143. The GC-FID results showed good agreement with the gravimetric values, confirming the validity of the preparation method. The certified values determined by gravimetry were established for 4 mixtures (B, C, D, E) as 12053.81 ± 97.49, 9013.23 ± 78.11, 5998.011 ± 57.72 and 2987.29 ± 66.91 µmol/mol, respectively. The mole fraction of the mixture F, 804.81 ± 35.97 µmol/mol was considered an information value since it was associated with large uncertainty of 7.016%. The performance of the produced certified reference materials (CRMs) was checked by using them to calibrate the GC-FID, then measure a CRM sample of 8010 µmol/mol as an unknown. The precision (%RSD) and accuracy of the measured results were found to be 0.12% and 99.75%, respectively. These results confirm that the prepared C3H8/N2 mixtures meet the criteria for certified reference materials and are suitable as calibrants for hydrocarbon emission measurement instruments in industrial gas analysis and environmental monitoring.
- 26 December 2025
- Published by ACG Publications in Journal of Chemical Metrology
- Vol. 19 (2) , 245-259
Development of a quality control material for conductivity measurements in food and environmental applications
The accuracy and reliability of conductivity measurements in analytical laboratories depend significantly on the availability of quality control materials. This study addresses the preparation, homogeneity, stability and characterization of a potassium chloride (KCl) quality control material (QCM) of 1414 µS/cm based on ISO/TR 33402. OIML R-56 does not contain this conductivity value as a secondary standard, so the mass of KCl required to prepare such a solution was experimentally defined. The conductivity measurements were carried out at 25 °C using a conductivity meter calibrated by a CRM produced by the the Slovak Institute of Metrology (SMU), a signatory to the mutual recognition arrangement (MRA) of the International Committee of Weights and Measures (CIPM). The homogeneity study was carried out in accordance with ISO 33405 using 10% of the batch bottles and the analysis of variance (ANOVA) showed that the QCM batch is homogeneous. The short-term stability was carried out over 4 weeks storage time at 4°C and 40°C and the isochronous measurements showed no significant deviations over time. The characterization of the QCM along three days showed that, its conductivity was 1414.11 µS/cm. The uncertainty associated with the conductivity measurements was assessed based on the requirements of the Guide to the expression of uncertainty in measurement (ISO GUM) and the EURACHEM/CITAC Guide, CG4 (Quantifying uncertainty in analytical measurement). It was found to be 23.10 µS/cm or 1.63%. A control chart was developed using the prepared QCM and the measured values remained within the control limits over the control time of six weeks. The prepared KCl QCM will be useful for use in quality control and instrumental validation in food, drug and environmental conductivity testing.
- 26 December 2025
- Published by ACG Publications in Journal of Chemical Metrology
- Vol. 19 (2) , 245-259
Development of a quality control material for conductivity measurements in food and environmental applications
The accuracy and reliability of conductivity measurements in analytical laboratories depend significantly on the availability of quality control materials. This study addresses the preparation, homogeneity, stability and characterization of a potassium chloride (KCl) quality control material (QCM) of 1414 µS/cm based on ISO/TR 33402. OIML R-56 does not contain this conductivity value as a secondary standard, so the mass of KCl required to prepare such a solution was experimentally defined. The conductivity measurements were carried out at 25 °C using a conductivity meter calibrated by a CRM produced by the the Slovak Institute of Metrology (SMU), a signatory to the mutual recognition arrangement (MRA) of the International Committee of Weights and Measures (CIPM). The homogeneity study was carried out in accordance with ISO 33405 using 10% of the batch bottles and the analysis of variance (ANOVA) showed that the QCM batch is homogeneous. The short-term stability was carried out over 4 weeks storage time at 4°C and 40°C and the isochronous measurements showed no significant deviations over time. The characterization of the QCM along three days showed that, its conductivity was 1414.11 µS/cm. The uncertainty associated with the conductivity measurements was assessed based on the requirements of the Guide to the expression of uncertainty in measurement (ISO GUM) and the EURACHEM/CITAC Guide, CG4 (Quantifying uncertainty in analytical measurement). It was found to be 23.10 µS/cm or 1.63%. A control chart was developed using the prepared QCM and the measured values remained within the control limits over the control time of six weeks. The prepared KCl QCM will be useful for use in quality control and instrumental validation in food, drug and environmental conductivity testing.
- Open Access
- 30 September 2025
- Published by Asian Publication Corporation in Asian Journal of Chemistry
- Vol. 37 (10) , 2500-2506
Development and Validation of a GC-ECD Method for the Determination of Trifluralin in Acetonitrile with Uncertainty Estimation
The use of trifluralin herbicide has raised concerns due to its persistence in the environment and potential toxicological impacts on human health and ecosystems. The aim of this study was to develop and validate a simple and reliable method for determining trifluralin residues in acetonitrile using gas chromatography with an electron capture detector (GC-ECD). The method was developed using internal standard calibration and validated in accordance with international guidelines. Validation parameters included LOD, LOQ, selectivity, linearity, precision, accuracy (recovery and bias) and measurement uncertainty. The method demonstrated high selectivity with no interfering peaks at the trifluralin retention time. A strong linear relationship was observed in the concentration range of 4-11 µg/g with a correlation coefficient (R2) of 0.9996. The precision, expressed as relative standard deviation (%RSD) was found 3.84% across all levels. Recovery values ranged from 98.45% to 100.06%, with % bias between 0.06% and 1.55% confirming the method accuracy. The expanded uncertainty was estimated to be 9.86% primarily influenced by sample and internal standard (IS) peak areas. The validated GC-ECD method provides a reliable, precise and accurate approach for quantifying trifluralin residues in environmental and food samples. It is suitable for routine monitoring, regulatory applications and risk assessments in agricultural and environmental contexts.
- 30 September 2025
- Published by Asian Publication Corporation in Asian Journal of Chemistry
- Vol. 37 (10) , 2500-2506
Open AccessDevelopment and Validation of a GC-ECD Method for the Determination of Trifluralin in Acetonitrile with Uncertainty Estimation
The use of trifluralin herbicide has raised concerns due to its persistence in the environment and potential toxicological impacts on human health and ecosystems. The aim of this study was to develop and validate a simple and reliable method for determining trifluralin residues in acetonitrile using gas chromatography with an electron capture detector (GC-ECD). The method was developed using internal standard calibration and validated in accordance with international guidelines. Validation parameters included LOD, LOQ, selectivity, linearity, precision, accuracy (recovery and bias) and measurement uncertainty. The method demonstrated high selectivity with no interfering peaks at the trifluralin retention time. A strong linear relationship was observed in the concentration range of 4-11 µg/g with a correlation coefficient (R2) of 0.9996. The precision, expressed as relative standard deviation (%RSD) was found 3.84% across all levels. Recovery values ranged from 98.45% to 100.06%, with % bias between 0.06% and 1.55% confirming the method accuracy. The expanded uncertainty was estimated to be 9.86% primarily influenced by sample and internal standard (IS) peak areas. The validated GC-ECD method provides a reliable, precise and accurate approach for quantifying trifluralin residues in environmental and food samples. It is suitable for routine monitoring, regulatory applications and risk assessments in agricultural and environmental contexts.
- 29 June 2023
- Published by ACG Publications in Journal of Chemical Metrology
- Vol. 17 (1)
Certification of buffer solutions reference materials using Baucke cell for supporting the quality of pH measurements
The need for certified pH reference materials to support the traceability claims and quality of the daily large volume of pH measurements is very strong. In this work, three batches of buffer solutions were prepared, and their pH values were certified in accordance with the IUPAC Recommendation 2002. The first batch was prepared from potassium tetraoxalate (dihydrate) and disodium oxalate to provide pH4 and the second batch was prepared from disodium hydrogen phosphate and potassium dihydrogen phosphate to provide pH7. The third batch was prepared from sodium hydrogen carbonate and sodium carbonate to provide pH10. Every batch was homogenized by mechanical shaking for one night and bottled into 50 HDPE bottles, each is 250 mL. A number of bottles were systematically selected for homogeneity, stability and characterization studies of the buffer reference materials. These studies were carried out in accordance with the requirements of ISO 17034 and ISO Guide 35 using Baucke cell. The pH values 4, 7 and 10 of the secondary buffers were restandardized with regard to the pH values 4, 7 and 10 of the primary buffers produced by the Slovak National Metrology Institute, SMU. The results obtained showed that the produced buffer RMs were homogeneous and stable enough and their certified pH values were found 4.001±0.019, 7.005±0.015 and 10.002±0.023. These CRMs will be very useful as calibrants and as PT samples for analytical laboratories performing pH measurements in various fields.
- 29 June 2023
- Published by ACG Publications in Journal of Chemical Metrology
- Vol. 17 (1)
Certification of buffer solutions reference materials using Baucke cell for supporting the quality of pH measurements
The need for certified pH reference materials to support the traceability claims and quality of the daily large volume of pH measurements is very strong. In this work, three batches of buffer solutions were prepared, and their pH values were certified in accordance with the IUPAC Recommendation 2002. The first batch was prepared from potassium tetraoxalate (dihydrate) and disodium oxalate to provide pH4 and the second batch was prepared from disodium hydrogen phosphate and potassium dihydrogen phosphate to provide pH7. The third batch was prepared from sodium hydrogen carbonate and sodium carbonate to provide pH10. Every batch was homogenized by mechanical shaking for one night and bottled into 50 HDPE bottles, each is 250 mL. A number of bottles were systematically selected for homogeneity, stability and characterization studies of the buffer reference materials. These studies were carried out in accordance with the requirements of ISO 17034 and ISO Guide 35 using Baucke cell. The pH values 4, 7 and 10 of the secondary buffers were restandardized with regard to the pH values 4, 7 and 10 of the primary buffers produced by the Slovak National Metrology Institute, SMU. The results obtained showed that the produced buffer RMs were homogeneous and stable enough and their certified pH values were found 4.001±0.019, 7.005±0.015 and 10.002±0.023. These CRMs will be very useful as calibrants and as PT samples for analytical laboratories performing pH measurements in various fields.
- 8 June 2021
- Published by ACG Publications in Journal of Chemical Metrology
- Vol. 15 (1) , 11-24
Preparation and certification of carbon monoxide gas reference material for the quality of CO emission measurements
Carbon monoxide emissions in air are toxic and its monitoring is of great concern worldwide. The monitoring activities should rely on traceable measurement results to the SI units. To serve this monitoring purpose in Saudi Arabia, a primary gas mixture (200 mmol/mol) of Carbon monoxide (CO) in nitrogen has been gravimetrically prepared from pure CO and pure N2 in 5L aluminum gas cylinder based on ISO 6142. From this mixture, three diluted mixtures of concentrations 4.99, 7.49 and 10.01 mmol/mol were prepared also in 5L cylinders and the uncertainty of these gravimetric preparations was calculated. The mole fractions of the three mixtures were verified by GC-TCD in accordance with ISO 6143 and the uncertainty of the chromatographic measurements was calculated. The gravimetrically and chromatographically measured mole fractions together with their standard uncertainties were found compatible indicating good quality of the produced primary gas mixtures. Long term stability of the three gas mixtures was monitored along four years, and the results obtained showed very good stability of the gas mixtures. The relative uncertainty of the GC analytical results was found 0.52%, 0.51% and 0.52% which is small enough and advantageous for the calibration of CO emission measuring equipment.
- 8 June 2021
- Published by ACG Publications in Journal of Chemical Metrology
- Vol. 15 (1) , 11-24
Preparation and certification of carbon monoxide gas reference material for the quality of CO emission measurements
Carbon monoxide emissions in air are toxic and its monitoring is of great concern worldwide. The monitoring activities should rely on traceable measurement results to the SI units. To serve this monitoring purpose in Saudi Arabia, a primary gas mixture (200 mmol/mol) of Carbon monoxide (CO) in nitrogen has been gravimetrically prepared from pure CO and pure N2 in 5L aluminum gas cylinder based on ISO 6142. From this mixture, three diluted mixtures of concentrations 4.99, 7.49 and 10.01 mmol/mol were prepared also in 5L cylinders and the uncertainty of these gravimetric preparations was calculated. The mole fractions of the three mixtures were verified by GC-TCD in accordance with ISO 6143 and the uncertainty of the chromatographic measurements was calculated. The gravimetrically and chromatographically measured mole fractions together with their standard uncertainties were found compatible indicating good quality of the produced primary gas mixtures. Long term stability of the three gas mixtures was monitored along four years, and the results obtained showed very good stability of the gas mixtures. The relative uncertainty of the GC analytical results was found 0.52%, 0.51% and 0.52% which is small enough and advantageous for the calibration of CO emission measuring equipment.
- 1 December 2020
- Published by ACG Publications in Journal of Chemical Metrology
- Vol. 14 (2) , 88-105
Certification of sodium benzoate solution reference material by HPLC-UV, LC-MS/MS and UV-VIS-NIR spectrophotometry for food and drug analysis
Sodium benzoate is one of the most widely used food perseverates and has to be used in regulated amounts to avoid its harmful health effects. Reviewing the scientific literature for traceability of the analytical measurement results of sodium benzoate in various food and drug applications to the SI units, it has been found that no scientific details of certification of sodium benzoate CRMs used for the calibration of measuring equipment are published. For this reason, the national metrology institute of Saudi Arabia (SASO/NMCC) certifies a sodium benzoate solution reference material. In this work, sodium benzoate was synthesized, purified and a batch solution reference material was prepared as 1014.47 mg/kg then homogenized and bottled. Homogeneity and stability of the candidate RM were assessed and the results obtained showed that the material is sufficiently homogeneous and stable. Characterization of the reference material was carried out by HPLC-UV, LC-MS/MS and UV-VIS-NIR spectrophotometer as three independent methods. The certified value was derived by combining data from the three methods using the weighted mean approach and was found 1016.13 mg/kg. The certified uncertainty was calculated as weighted uncertainty and was found 10.47 mg/kg (1.03%). Sources of this uncertainty were identified from the characterization, uchar, homogeneity, uhom, and long-term stability, ults, as well as the bias allowance, B.
- 1 December 2020
- Published by ACG Publications in Journal of Chemical Metrology
- Vol. 14 (2) , 88-105
Certification of sodium benzoate solution reference material by HPLC-UV, LC-MS/MS and UV-VIS-NIR spectrophotometry for food and drug analysis
Sodium benzoate is one of the most widely used food perseverates and has to be used in regulated amounts to avoid its harmful health effects. Reviewing the scientific literature for traceability of the analytical measurement results of sodium benzoate in various food and drug applications to the SI units, it has been found that no scientific details of certification of sodium benzoate CRMs used for the calibration of measuring equipment are published. For this reason, the national metrology institute of Saudi Arabia (SASO/NMCC) certifies a sodium benzoate solution reference material. In this work, sodium benzoate was synthesized, purified and a batch solution reference material was prepared as 1014.47 mg/kg then homogenized and bottled. Homogeneity and stability of the candidate RM were assessed and the results obtained showed that the material is sufficiently homogeneous and stable. Characterization of the reference material was carried out by HPLC-UV, LC-MS/MS and UV-VIS-NIR spectrophotometer as three independent methods. The certified value was derived by combining data from the three methods using the weighted mean approach and was found 1016.13 mg/kg. The certified uncertainty was calculated as weighted uncertainty and was found 10.47 mg/kg (1.03%). Sources of this uncertainty were identified from the characterization, uchar, homogeneity, uhom, and long-term stability, ults, as well as the bias allowance, B.