Tongyuan Zhang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Tongyuan Zhang has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Bingkun Li
Southwest Jiaotong University
2 shared publications - Guangning Wu
Southwest Jiaotong University
2 shared publications - Song Xiao
Southwest Jiaotong University
2 shared publications - Xueqin Zhang
Southwest Jiaotong University
2 shared publications - Yujun Guo
School of Electrical Engineering Southwest Jiaotong University Chengdu China
2 shared publications - Chenguang Yang
School of Electrical Engineering, Southwest Jiaotong University, Chengdu, China
1 shared publication
Latest Publications
- 28 October 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 33 (2) , 1400-1410
Impact of Contamination on AC Flashover Performance of Contact Network Insulators Under High-Fouling Tunnel Conditions
The semi-enclosed environment of railway tunnels intensifies the accumulation of natural contamination on insulating surfaces. However, the natural contamination and flashover characteristics of railway tunnel insulators are underexplored. This study investigates the accumulation of contamination on railway tunnel insulators, focusing on equivalent salt deposit density (ESDD), non-soluble deposit density (NSDD), the NSDD/ESDD ratio (KN/E), and contamination non-uniformity (K). The chemical composition, particle size, and insoluble components of contamination are also analyzed. Results show peak contamination at tunnel entrances/exits. ESDD ranges from 0.1 to 1.1 mg/cm2, and NSDD from 2 to 18 mg/cm2, with larger particles (>10 μm) concentrated at entrances/exits. Compared to other regions, the KN/E ratio inside the tunnel (1.7-23.4) is higher, and tunnel contamination is E level (nonuniformity KESDD: 1/2.19-1/1.44), while external contamination is typically B level due to rainfall. The study examines the effects of pressure, ESDD, and K on flashover voltage, with multi-factor ANOVA showing ESDD as the dominant factor, with the strongest interaction between ESDD and pressure. Compared to different shed parameters, the optimal S/L ratio for flashover performance ranges from 1.55 to 1.77, with larger ratios (1.77) suited for light pollution environments and smaller ratios (1.55) for heavy pollution. Additionally, insoluble components like metal oxides and carbon reduce flashover voltage and increase leakage current by shortening the creepage distance and enhancing conductivity and arc stability. These findings offer key insights for external insulation configuration, designing, and artificial contamination testing in high-altitude railway tunnels.
- 28 October 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 33 (2) , 1400-1410
Impact of Contamination on AC Flashover Performance of Contact Network Insulators Under High-Fouling Tunnel Conditions
The semi-enclosed environment of railway tunnels intensifies the accumulation of natural contamination on insulating surfaces. However, the natural contamination and flashover characteristics of railway tunnel insulators are underexplored. This study investigates the accumulation of contamination on railway tunnel insulators, focusing on equivalent salt deposit density (ESDD), non-soluble deposit density (NSDD), the NSDD/ESDD ratio (KN/E), and contamination non-uniformity (K). The chemical composition, particle size, and insoluble components of contamination are also analyzed. Results show peak contamination at tunnel entrances/exits. ESDD ranges from 0.1 to 1.1 mg/cm2, and NSDD from 2 to 18 mg/cm2, with larger particles (>10 μm) concentrated at entrances/exits. Compared to other regions, the KN/E ratio inside the tunnel (1.7-23.4) is higher, and tunnel contamination is E level (nonuniformity KESDD: 1/2.19-1/1.44), while external contamination is typically B level due to rainfall. The study examines the effects of pressure, ESDD, and K on flashover voltage, with multi-factor ANOVA showing ESDD as the dominant factor, with the strongest interaction between ESDD and pressure. Compared to different shed parameters, the optimal S/L ratio for flashover performance ranges from 1.55 to 1.77, with larger ratios (1.77) suited for light pollution environments and smaller ratios (1.55) for heavy pollution. Additionally, insoluble components like metal oxides and carbon reduce flashover voltage and increase leakage current by shortening the creepage distance and enhancing conductivity and arc stability. These findings offer key insights for external insulation configuration, designing, and artificial contamination testing in high-altitude railway tunnels.