Yuyang Guo
Research Subjects
Yuyang Guo has a total of 36 co-authors. Here are the top co-authors by number of shared publications:
- Jiaxing Lu
Key Laboratory of Fluid and Power Machinery, Ministry of Education, Xihua University, Chengdu 610039, China
10 shared publications Hui Li
6 shared publications- Ming Zhao6 shared publications
Gang Yu
2 shared publicationsJian Huang
2 shared publicationsJunhui Zhang
2 shared publications
Latest Publications
- Open Access
- 5 August 2026
- Published by Elsevier in SSRN Electronic Journal
Blade trailing edge optimization for diffuser centrifugal pumps in marine applications: Enhancing energy efficiency and suppressing rotor-stator interaction toward low-carbon marine pumping systems
Centrifugal pumps are vital in offshore cooling, seawater lifting, ballasting and ocean energy conversion, but rotor-stator interaction (RSI) causes pressure pulsation, flow instability and energy loss. BTE geometry governs pressure wave propagation in the impeller-diffuser gap, yet its attenuation mechanism for marine pumps is unclear. We propose two BTE designs: M1 (fourth-order Bézier thin edge) and M2 (30 mm fillet), with original as M0. Hybrid experiments, CFD and spectrum analysis compare the three. Results show M1 and M2 shrink outlet low-pressure zones, mitigate blade-sweeping pressure drop, and improve circumferential uniformity. M1 and M2 reduce diffuser-inlet pulsation amplitude by 40–50% and 25–35%, respectively. Maximum static pressure difference per passage falls from 0.51×10⁵ (M0) to 0.28×10⁵ (M1) and 0.35×10⁵ (M2). M1 offers best suppression; M2 improves efficiency and head at low flow, balancing stability and efficiency. Optimized BTE geometries boost efficiency by 0.9–1.2 percentage points. For a 15 kW pump at 5000 h/year, M2 saves 900–1200 kWh and cuts CO₂ by 450–600 kg/year. Remodeling BTE stabilizes pressure waves, providing guidelines and a low-carbon foundation.
- 5 August 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessBlade trailing edge optimization for diffuser centrifugal pumps in marine applications: Enhancing energy efficiency and suppressing rotor-stator interaction toward low-carbon marine pumping systems
Centrifugal pumps are vital in offshore cooling, seawater lifting, ballasting and ocean energy conversion, but rotor-stator interaction (RSI) causes pressure pulsation, flow instability and energy loss. BTE geometry governs pressure wave propagation in the impeller-diffuser gap, yet its attenuation mechanism for marine pumps is unclear. We propose two BTE designs: M1 (fourth-order Bézier thin edge) and M2 (30 mm fillet), with original as M0. Hybrid experiments, CFD and spectrum analysis compare the three. Results show M1 and M2 shrink outlet low-pressure zones, mitigate blade-sweeping pressure drop, and improve circumferential uniformity. M1 and M2 reduce diffuser-inlet pulsation amplitude by 40–50% and 25–35%, respectively. Maximum static pressure difference per passage falls from 0.51×10⁵ (M0) to 0.28×10⁵ (M1) and 0.35×10⁵ (M2). M1 offers best suppression; M2 improves efficiency and head at low flow, balancing stability and efficiency. Optimized BTE geometries boost efficiency by 0.9–1.2 percentage points. For a 15 kW pump at 5000 h/year, M2 saves 900–1200 kWh and cuts CO₂ by 450–600 kg/year. Remodeling BTE stabilizes pressure waves, providing guidelines and a low-carbon foundation.
- Open Access
- 3 July 2026
- Published by Elsevier in SSRN Electronic Journal
Study on hydraulic losses in fixed flow passage components of a Pelton turbine under sedimentladen flow
Pelton turbines are increasingly widely applied in hydropower development in highhead, sedimentladen rivers in Southwest China. However, the hydraulic loss mechanisms in their fixed flow passage components (distributor and injector) under sedimentladen flow conditions remain unclear, and traditional methods are inadequate to precisely locate loss sources and quantify sediment impacts. To address this issue, this paper takes a sixnozzle Pelton turbine with four deflectors as the research object, establishes a gasliquidsolid threephase numerical simulation method based on the VOF multiphase model, the SST kω turbulence model, and the DPM discrete phase model, and introduces the entropy production theory to quantitatively evaluate and spatially resolve the energy losses in the distributor and injector under both clearwater and sedimentladen conditions.The results indicate that sediment-laden flow increases the indirect entropy production in the entire flow passage by approximately 20% compared with clear-water conditions, with the increments concentrated at the trailing edge of the deflectors, the needle tail, and the distributor bifurcations. The inertial perturbation of sediment particles expands the region of direct entropy production and exacerbates turbulent dissipation through particlevortex coupling, leading to a significant deterioration of jet stability at the nozzle outlet. The inlet flow fields of different nozzles exhibit notable differences due to the transport of secondary flow from the distributor. Although the deflectors can effectively rectify the flow, the Kármán vortex street at their trailing edge induces additional losses. Moreover, extending the trailingedge length of the deflector (560 mm scheme) can smooth the adverse pressure gradient, delay boundary layer separation, and effectively reduce the energy dissipation in the shear layer. This study quantitatively reveals the enhancement mechanism of sediment on hydraulic losses in fixed flow passage components and the regulating effect of deflector geometry, providing a theoretical basis for efficiency improvement and antierosion optimization design of Pelton turbines in high sedimentladen regions.
- 3 July 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessStudy on hydraulic losses in fixed flow passage components of a Pelton turbine under sedimentladen flow
Pelton turbines are increasingly widely applied in hydropower development in highhead, sedimentladen rivers in Southwest China. However, the hydraulic loss mechanisms in their fixed flow passage components (distributor and injector) under sedimentladen flow conditions remain unclear, and traditional methods are inadequate to precisely locate loss sources and quantify sediment impacts. To address this issue, this paper takes a sixnozzle Pelton turbine with four deflectors as the research object, establishes a gasliquidsolid threephase numerical simulation method based on the VOF multiphase model, the SST kω turbulence model, and the DPM discrete phase model, and introduces the entropy production theory to quantitatively evaluate and spatially resolve the energy losses in the distributor and injector under both clearwater and sedimentladen conditions.The results indicate that sediment-laden flow increases the indirect entropy production in the entire flow passage by approximately 20% compared with clear-water conditions, with the increments concentrated at the trailing edge of the deflectors, the needle tail, and the distributor bifurcations. The inertial perturbation of sediment particles expands the region of direct entropy production and exacerbates turbulent dissipation through particlevortex coupling, leading to a significant deterioration of jet stability at the nozzle outlet. The inlet flow fields of different nozzles exhibit notable differences due to the transport of secondary flow from the distributor. Although the deflectors can effectively rectify the flow, the Kármán vortex street at their trailing edge induces additional losses. Moreover, extending the trailingedge length of the deflector (560 mm scheme) can smooth the adverse pressure gradient, delay boundary layer separation, and effectively reduce the energy dissipation in the shear layer. This study quantitatively reveals the enhancement mechanism of sediment on hydraulic losses in fixed flow passage components and the regulating effect of deflector geometry, providing a theoretical basis for efficiency improvement and antierosion optimization design of Pelton turbines in high sedimentladen regions.
- Open Access
- 3 July 2026
- Published by Elsevier in SSRN Electronic Journal
POD-Based modal decomposition and reduced-order modeling for full-range unsteady flow in a residual pressure recovery turbine
To characterize the unsteady flow behavior of a residual pressure recovery hydraulic turbine across its entire operating range, the transient pressure and velocity fields at three typical flow rates—0.7 Qd, Qd, and 1.3 Qd—were modally decomposed using proper orthogonal decomposition (POD). Combined with turbulent kinetic energy (TKE) contours and the Q-criterion vortex identification method, the topological evolution of the flow field and the energy distribution characteristics of the dominant modes were systematically revealed under different flow conditions. The results show that the variation of the inflow incidence angle is the critical factor driving the fundamental change in the flow field structure. Under the rated condition, a zero incidence angle ensured smooth flow attachment; the blade passing frequency (BPF) induced by rotor–stator interaction (RSI) became the sole dominant source of flow fluctuations. The flow field exhibited strong low-dimensional characteristics: the first four pressure and velocity modes captured more than 95% of the total modal energy, and retaining only four modes was sufficient to keep the relative reconstruction error below 10⁻³. Under the low-flow condition, the positive incidence angle induced flow separation on the suction surface and generated discrete blade passage vortices, causing the flow energy to be widely dispersed; at least 12 modes had to be retained to achieve the same reconstruction accuracy. Under the high-flow condition, the negative incidence angle led to large-scale separation on the pressure surface, and a large-scale central helical instability structure appeared in the flow passage. The flow field exhibited mixed convergence characteristics of BPF periodicity and helical instability, and retaining eight modes effectively balanced computational accuracy and efficiency. In this study, the optimal modal truncation orders of the POD-based reduced-order model across the entire operating range were quantitatively and precisely determined. These findings provide an essential theoretical basis and data support for rapid flow field reconstruction, hydraulic excitation suppression, and blade profile optimization of residual pressure recovery hydraulic turbines under off-design conditions.
- 3 July 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessPOD-Based modal decomposition and reduced-order modeling for full-range unsteady flow in a residual pressure recovery turbine
To characterize the unsteady flow behavior of a residual pressure recovery hydraulic turbine across its entire operating range, the transient pressure and velocity fields at three typical flow rates—0.7 Qd, Qd, and 1.3 Qd—were modally decomposed using proper orthogonal decomposition (POD). Combined with turbulent kinetic energy (TKE) contours and the Q-criterion vortex identification method, the topological evolution of the flow field and the energy distribution characteristics of the dominant modes were systematically revealed under different flow conditions. The results show that the variation of the inflow incidence angle is the critical factor driving the fundamental change in the flow field structure. Under the rated condition, a zero incidence angle ensured smooth flow attachment; the blade passing frequency (BPF) induced by rotor–stator interaction (RSI) became the sole dominant source of flow fluctuations. The flow field exhibited strong low-dimensional characteristics: the first four pressure and velocity modes captured more than 95% of the total modal energy, and retaining only four modes was sufficient to keep the relative reconstruction error below 10⁻³. Under the low-flow condition, the positive incidence angle induced flow separation on the suction surface and generated discrete blade passage vortices, causing the flow energy to be widely dispersed; at least 12 modes had to be retained to achieve the same reconstruction accuracy. Under the high-flow condition, the negative incidence angle led to large-scale separation on the pressure surface, and a large-scale central helical instability structure appeared in the flow passage. The flow field exhibited mixed convergence characteristics of BPF periodicity and helical instability, and retaining eight modes effectively balanced computational accuracy and efficiency. In this study, the optimal modal truncation orders of the POD-based reduced-order model across the entire operating range were quantitatively and precisely determined. These findings provide an essential theoretical basis and data support for rapid flow field reconstruction, hydraulic excitation suppression, and blade profile optimization of residual pressure recovery hydraulic turbines under off-design conditions.
- Open Access
- 24 June 2026
- Published by Elsevier in SSRN Electronic Journal
Numerical and Experimental Study on Flow Instabilities of a Pump-Turbine in Pump Operating Condition at Low Flow Rates
Pumped storage units play an increasingly important role in peak regulation and frequency modulation. Pump-turbines, as the core equipment of pumped storage power stations, frequently operate at off-design conditions especially low-flow pump mode, seriously threatening unit safety and operational stability. Pump-turbines often suffer from severe flow instabilities under low-flow pump conditions, which restrict the operational safety and efficiency of pumped storage units. In this work, experimental tests and full-passage unsteady CFD simulations are jointly applied to explore the unstable flow characteristics of a Francis pump-turbine at part-load pump mode. Four typical flow rates are selected(0.5Qd, 0.55Qd, 0.6Qd and 1.0Qd),the SST k-ω turbulence model and Q-criterion are employed to capture internal flow fields and vortex structures. The evolution of flow separation, jet-wake, rotor-stator interaction and rotating stall are analyzed at design flow rate and two low-flow conditions. Pressure pulsation signals of key components are processed via FFT to obtain frequency-domain characteristics. The results indicate that flow separation is aggravated with the decrease of flow rate and eventually induces rotating stall. Four stall cells uniformly distribute in the guide vane region, and their dominant frequency is 0.26 fn. Rotating stall propagates circumferentially and interacts with other unstable flows to intensify flow disorder. The numerical results are well consistent with experimental data within a relative error of 5%. This work clarifies the coupling mechanism of various unstable flows under low-flow pump mode, and offers technical support for the stable operation of pump-turbines.
- 24 June 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessNumerical and Experimental Study on Flow Instabilities of a Pump-Turbine in Pump Operating Condition at Low Flow Rates
Pumped storage units play an increasingly important role in peak regulation and frequency modulation. Pump-turbines, as the core equipment of pumped storage power stations, frequently operate at off-design conditions especially low-flow pump mode, seriously threatening unit safety and operational stability. Pump-turbines often suffer from severe flow instabilities under low-flow pump conditions, which restrict the operational safety and efficiency of pumped storage units. In this work, experimental tests and full-passage unsteady CFD simulations are jointly applied to explore the unstable flow characteristics of a Francis pump-turbine at part-load pump mode. Four typical flow rates are selected(0.5Qd, 0.55Qd, 0.6Qd and 1.0Qd),the SST k-ω turbulence model and Q-criterion are employed to capture internal flow fields and vortex structures. The evolution of flow separation, jet-wake, rotor-stator interaction and rotating stall are analyzed at design flow rate and two low-flow conditions. Pressure pulsation signals of key components are processed via FFT to obtain frequency-domain characteristics. The results indicate that flow separation is aggravated with the decrease of flow rate and eventually induces rotating stall. Four stall cells uniformly distribute in the guide vane region, and their dominant frequency is 0.26 fn. Rotating stall propagates circumferentially and interacts with other unstable flows to intensify flow disorder. The numerical results are well consistent with experimental data within a relative error of 5%. This work clarifies the coupling mechanism of various unstable flows under low-flow pump mode, and offers technical support for the stable operation of pump-turbines.
- Open Access
- 24 June 2026
- Published by Elsevier in SSRN Electronic Journal
Effect of runner blade number on off-design hydraulic performance and flow stability of a residual pressure recovery turbine
To mitigate the substantial dissipation of pressure energy by pressure reducing valves (PRVs) in urban water distribution networks, this study examines a pipe-type residual-pressure recovery turbine. By integrating computational fluid dynamics (CFD) with entropy production analysis, a systematic comparative investigation was performed on runners with blade counts of 13, 14, and 15 under off-design operating conditions (Q = 0.7Qd), elucidating the hydraulic performance, internal vortical flow structures, pressure fluctuation characteristics, and energy loss mechanisms.,The results demonstrate that an increased blade number effectively restrains suction-side flow separation and passage vortices triggered by incidence angle mismatch under reduced-flow conditions, consequently attenuating turbulence dissipation losses. Nevertheless, an excessive blade count (Z = 15) intensifies leading-edge impingement losses and rotor–stator interaction. The 14-blade runner strikes an optimal balance between suppressing separation vortices and controlling additional losses, achieving an off-design efficiency of 79.78%—markedly surpassing that of the 13-blade configuration (76.87%) while remaining comparable to the 15-blade scheme (79.94%).Furthermore, the 14-blade runner exhibits the minimum average vortex volume and pressure fluctuation amplitudes among the three candidates, with pronounced attenuation of both low-frequency broadband perturbations and blade-passing-frequency dominant peaks. Entropy production analysis further corroborates that the 14-blade configuration yields a more uniform entropy generation distribution and substantially diminished irreversible losses within the runner domain.,Collectively, these findings establish the 14-blade configuration as the preferred design that concurrently accommodates wide-load hydraulic efficiency, hydrodynamic stability, and engineering economy, thereby furnishing theoretical foundations for blade-number optimization of residual-pressure recovery turbines in water supply networks.
- 24 June 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessEffect of runner blade number on off-design hydraulic performance and flow stability of a residual pressure recovery turbine
To mitigate the substantial dissipation of pressure energy by pressure reducing valves (PRVs) in urban water distribution networks, this study examines a pipe-type residual-pressure recovery turbine. By integrating computational fluid dynamics (CFD) with entropy production analysis, a systematic comparative investigation was performed on runners with blade counts of 13, 14, and 15 under off-design operating conditions (Q = 0.7Qd), elucidating the hydraulic performance, internal vortical flow structures, pressure fluctuation characteristics, and energy loss mechanisms.,The results demonstrate that an increased blade number effectively restrains suction-side flow separation and passage vortices triggered by incidence angle mismatch under reduced-flow conditions, consequently attenuating turbulence dissipation losses. Nevertheless, an excessive blade count (Z = 15) intensifies leading-edge impingement losses and rotor–stator interaction. The 14-blade runner strikes an optimal balance between suppressing separation vortices and controlling additional losses, achieving an off-design efficiency of 79.78%—markedly surpassing that of the 13-blade configuration (76.87%) while remaining comparable to the 15-blade scheme (79.94%).Furthermore, the 14-blade runner exhibits the minimum average vortex volume and pressure fluctuation amplitudes among the three candidates, with pronounced attenuation of both low-frequency broadband perturbations and blade-passing-frequency dominant peaks. Entropy production analysis further corroborates that the 14-blade configuration yields a more uniform entropy generation distribution and substantially diminished irreversible losses within the runner domain.,Collectively, these findings establish the 14-blade configuration as the preferred design that concurrently accommodates wide-load hydraulic efficiency, hydrodynamic stability, and engineering economy, thereby furnishing theoretical foundations for blade-number optimization of residual-pressure recovery turbines in water supply networks.
- Open Access
- 15 June 2026
- Published by Elsevier in SSRN Electronic Journal
Blade trailing edge optimization for diffuser centrifugal pumps in marine applications: Enhancing energy efficiency and suppressing rotor-stator interaction toward low-carbon marine pumping systems
Centrifugal pumps are key energy-consuming equipment in marine engineering. Rotor-stator interaction (RSI) in diffuser centrifugal pumps causes severe pressure pulsation, vibration and energy loss, especially under variable marine conditions. Blade trailing edge (BTE) geometry dominates flow and vortex dynamics in the RSI region, yet its coupled mechanism with pressure wave propagation remains unclear. This study proposes two novel BTE designs: a fourth-order Bézier thin trailing edge (M1) and a 30 mm pressure-side fillet trailing edge (M2), investigated via CFD, closed-loop experiments, spatiotemporal pressure analysis and Ω vortex identification. Results show optimized BTEs improve static pressure distribution and flow uniformity, and suppress large-scale vortex clustering. M1 achieves the best pressure pulsation attenuation at the diffuser inlet, while M2 enhances efficiency by 0.9–1.2 percentage points under all conditions. A new RSI suppression mechanism is revealed: BTE optimization weakens vortex-induced disturbances and stabilizes pressure wave propagation. The proposed designs save 900–1200 kWh and reduce CO₂ emissions by 450–600 kg annually for a typical 15 kW marine pump. This work provides theoretical and practical guidance for high-efficiency, low-pulsation marine centrifugal pumps, supporting low-carbon and sustainable marine power systems.
- 15 June 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessBlade trailing edge optimization for diffuser centrifugal pumps in marine applications: Enhancing energy efficiency and suppressing rotor-stator interaction toward low-carbon marine pumping systems
Centrifugal pumps are key energy-consuming equipment in marine engineering. Rotor-stator interaction (RSI) in diffuser centrifugal pumps causes severe pressure pulsation, vibration and energy loss, especially under variable marine conditions. Blade trailing edge (BTE) geometry dominates flow and vortex dynamics in the RSI region, yet its coupled mechanism with pressure wave propagation remains unclear. This study proposes two novel BTE designs: a fourth-order Bézier thin trailing edge (M1) and a 30 mm pressure-side fillet trailing edge (M2), investigated via CFD, closed-loop experiments, spatiotemporal pressure analysis and Ω vortex identification. Results show optimized BTEs improve static pressure distribution and flow uniformity, and suppress large-scale vortex clustering. M1 achieves the best pressure pulsation attenuation at the diffuser inlet, while M2 enhances efficiency by 0.9–1.2 percentage points under all conditions. A new RSI suppression mechanism is revealed: BTE optimization weakens vortex-induced disturbances and stabilizes pressure wave propagation. The proposed designs save 900–1200 kWh and reduce CO₂ emissions by 450–600 kg annually for a typical 15 kW marine pump. This work provides theoretical and practical guidance for high-efficiency, low-pulsation marine centrifugal pumps, supporting low-carbon and sustainable marine power systems.
- Open Access
- 25 May 2026
- Published by Elsevier in SSRN Electronic Journal
A digital-twin framework for rapid field-level prediction using parametric POD-ROM and Phase-Locked transient analysis
A digital-twin framework for efficient prediction of field-level quantities in pump-turbine systems using a reduced-order modeling (ROM) approach is presented in this paper. The framework integrates a parametric POD-ROM for steady-state predictions and a phase-locked Fourier representation for transient simulations, enabling rapid reconstruction of blade-surface pressure and velocity distributions. Although pressure and velocity are used as representative examples, the framework is agnostic to specific variables and can be extended to any monitored scalar or vector quantity. The steady-state POD-ROM demonstrated high accuracy with global relative L2errors of 0.55% for pressure and 3.0% for velocity, while pointwise relative errors for pressure and velocity were below 7.6% and 19.2% at the 95th percentile, respectively. For transient simulations, the phase-locked Fourier state efficiently captures rotor-synchronous loading, with computational times on the order of milliseconds for real-time inference, offering substantial advantages over traditional CFD simulations. The proposed methodology is validated through comparisons with CFD reference data, showing high fidelity for both steady and transient predictions. This approach provides a powerful tool for real-time digital-twin applications in energy systems, facilitating predictive maintenance and operational optimization.
- 25 May 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessA digital-twin framework for rapid field-level prediction using parametric POD-ROM and Phase-Locked transient analysis
A digital-twin framework for efficient prediction of field-level quantities in pump-turbine systems using a reduced-order modeling (ROM) approach is presented in this paper. The framework integrates a parametric POD-ROM for steady-state predictions and a phase-locked Fourier representation for transient simulations, enabling rapid reconstruction of blade-surface pressure and velocity distributions. Although pressure and velocity are used as representative examples, the framework is agnostic to specific variables and can be extended to any monitored scalar or vector quantity. The steady-state POD-ROM demonstrated high accuracy with global relative L2errors of 0.55% for pressure and 3.0% for velocity, while pointwise relative errors for pressure and velocity were below 7.6% and 19.2% at the 95th percentile, respectively. For transient simulations, the phase-locked Fourier state efficiently captures rotor-synchronous loading, with computational times on the order of milliseconds for real-time inference, offering substantial advantages over traditional CFD simulations. The proposed methodology is validated through comparisons with CFD reference data, showing high fidelity for both steady and transient predictions. This approach provides a powerful tool for real-time digital-twin applications in energy systems, facilitating predictive maintenance and operational optimization.
- Open Access
- 10 February 2026
- Published by Elsevier in SSRN Electronic Journal
Identification of Safe-Aeration Concentration and Energy Dissipation Characteristic in Pumping Mode of a Pump-Turbine
In pumped storage systems, the pump-turbine serves as the core energy conversion component, and its operating efficiency directly influences the overall performance and energy loss of the storage system. Cavitation is a key factor leading to efficiency degradation and structural damage, while aeration, as an active control method, can suppress cavitation but may also introduce additional flow instability and energy loss. Currently, how to maximize energy conversion efficiency and minimize losses during the aeration process remains a critical scientific issue to be addressed in energy storage technology.This study integrates full-flow-field visualization experiments with coupled CFD-PBM-entropy production numerical simulations to systematically reveal the influence mechanism of aeration concentration on the energy conversion process in pump-turbines under pump mode. By establishing an Eulerian–Eulerian two-fluid model coupled with a population balance model and incorporating entropy production theory, the spatial distribution of energy dissipation under different aeration conditions is quantified from a thermodynamic perspective. The research finds that there exists a safe aeration concentration window (α = 0.005-0.03), within which aeration can effectively suppress vibration while maintaining stable hydraulic efficiency and relatively low energy loss. Once the critical threshold (α ≈ 0.045) is exceeded, intensified bubble accumulation and breakup in the runner inter-blade passages trigger vortex structure complexity and localized concentration of turbulent kinetic energy, leading to a significant increase in entropy production rate, a sharp drop in efficiency, and a peak in additional loss power. For the first time, this study clarifies the dual-impact mechanism of aeration on energy conversion and performance in pump-turbines from the perspective of energy dissipation, providing a theoretical basis and quantitative operational guidance for aeration optimization and efficient energy management in pumped-storage power stations. The relevant findings hold significant engineering importance for enhancing the operational stability of energy storage systems and reducing energy loss.
- 10 February 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessIdentification of Safe-Aeration Concentration and Energy Dissipation Characteristic in Pumping Mode of a Pump-Turbine
In pumped storage systems, the pump-turbine serves as the core energy conversion component, and its operating efficiency directly influences the overall performance and energy loss of the storage system. Cavitation is a key factor leading to efficiency degradation and structural damage, while aeration, as an active control method, can suppress cavitation but may also introduce additional flow instability and energy loss. Currently, how to maximize energy conversion efficiency and minimize losses during the aeration process remains a critical scientific issue to be addressed in energy storage technology.This study integrates full-flow-field visualization experiments with coupled CFD-PBM-entropy production numerical simulations to systematically reveal the influence mechanism of aeration concentration on the energy conversion process in pump-turbines under pump mode. By establishing an Eulerian–Eulerian two-fluid model coupled with a population balance model and incorporating entropy production theory, the spatial distribution of energy dissipation under different aeration conditions is quantified from a thermodynamic perspective. The research finds that there exists a safe aeration concentration window (α = 0.005-0.03), within which aeration can effectively suppress vibration while maintaining stable hydraulic efficiency and relatively low energy loss. Once the critical threshold (α ≈ 0.045) is exceeded, intensified bubble accumulation and breakup in the runner inter-blade passages trigger vortex structure complexity and localized concentration of turbulent kinetic energy, leading to a significant increase in entropy production rate, a sharp drop in efficiency, and a peak in additional loss power. For the first time, this study clarifies the dual-impact mechanism of aeration on energy conversion and performance in pump-turbines from the perspective of energy dissipation, providing a theoretical basis and quantitative operational guidance for aeration optimization and efficient energy management in pumped-storage power stations. The relevant findings hold significant engineering importance for enhancing the operational stability of energy storage systems and reducing energy loss.