Artem Babaiev
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Artem Babaiev has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Alexander Yudin
National technical university «Kharkiv polytechnic institute
3 shared publications - Olena Avdieieva
Department of Computer Modeling of Processes and Systems, National Technical University “Kharkiv Polytechnic Institute”, 61002 Kharkiv, Ukraine
3 shared publications - Valentyn Barannik
National technical university «Kharkiv polytechnic institute
3 shared publications - Ivan Babayev
JSC Ukrainian Energy Machines, Kharkiv, Ukraine
1 shared publication - Valery Subotovich
Anatolii Pidhornyi Institute of Power Machines and Systems of the National Academy of Sciences of Ukraine
1 shared publication
Latest Publications
- Open Access
- 6 August 2026
- Published by National Technical University Kharkiv Polytechnic Institute in Bulletin of the National Technical University "KhPI". Series: Hydraulic machines and hydraulic units
- No. 1,p. 39-44
COMPARATIVE ANALYSIS OF DYNAMIC PROPERTIES OF STEAM TURBINE SLIDE VALVE CONNECTION SCHEMES
The article discusses the advantages and disadvantages of different connection schemes of slide valves into the hydraulic section of electro-hydraulicregulation and protection systems of steam turbines. A comparative analysis of three schemes is presented, which are currently the most widely used insteam turbines of thermal power plants in Ukraine. In the first scheme, the slide valve is completely unloaded from the influence of pressures. Tointeract with the protection system, a spring-based disengagement mechanism is installed on the slide valve, separating the rods of the electromechanicalconverter and the slide valve stem. A ball switch is also installed, which controls the pressure in the hydraulic line supplying pressure fordisengaging the slide valve and electro-mechanical converter rods according to turbine protection system commands. In the second scheme, the slidevalve also has a spring-based disengagement mechanism between the slide valve rods and the electro-mechanical converter, but a turbine protectionline is connected directly to the slide valve. Actuation of the slide valve upon pressure release in the protection line occurs under the action of thedisengagement spring. In the third scheme, the disengagement mechanism between the slide valve and valve rods is implemented without springs,relying solely on the action of power pressure and protection-line pressure acting on the slide valve chambers. Actuation of the slide valve uponpressure release in the protection line occurs due to the power pressure. For each scheme, mathematical models were developed, consisting of systemsof nonlinear differential and algebraic equations. A computational analysis of the dynamic characteristics of slide valves within the three schemes wasperformed using the example designs of valves from K-160-130 and K-300-240 turbines. To evaluate dynamic performance, the turbine operatingmode during a sudden disconnection of the generator from the electrical grid was selected. The results show that the first scheme provides the bestresponse speed. The second and third schemes not only have lower response speed but also negatively affect the stability of pressure in the turbineprotection line. The use of the second scheme in systems where multiple slide valves must operate simultaneously under certain operating conditionsmay lead to an unintended turbine shutdown. In conclusion, the use of the first slide valve connection scheme is recommended. The obtained resultscan be used for the modernization of automatic control and protection systems of steam turbines when implementing electro-hydraulic control systems.
- 6 August 2026
- Published by National Technical University Kharkiv Polytechnic Institute in Bulletin of the National Technical University "KhPI". Series: Hydraulic machines and hydraulic units
- No. 1,p. 39-44
Open AccessCOMPARATIVE ANALYSIS OF DYNAMIC PROPERTIES OF STEAM TURBINE SLIDE VALVE CONNECTION SCHEMES
The article discusses the advantages and disadvantages of different connection schemes of slide valves into the hydraulic section of electro-hydraulicregulation and protection systems of steam turbines. A comparative analysis of three schemes is presented, which are currently the most widely used insteam turbines of thermal power plants in Ukraine. In the first scheme, the slide valve is completely unloaded from the influence of pressures. Tointeract with the protection system, a spring-based disengagement mechanism is installed on the slide valve, separating the rods of the electromechanicalconverter and the slide valve stem. A ball switch is also installed, which controls the pressure in the hydraulic line supplying pressure fordisengaging the slide valve and electro-mechanical converter rods according to turbine protection system commands. In the second scheme, the slidevalve also has a spring-based disengagement mechanism between the slide valve rods and the electro-mechanical converter, but a turbine protectionline is connected directly to the slide valve. Actuation of the slide valve upon pressure release in the protection line occurs under the action of thedisengagement spring. In the third scheme, the disengagement mechanism between the slide valve and valve rods is implemented without springs,relying solely on the action of power pressure and protection-line pressure acting on the slide valve chambers. Actuation of the slide valve uponpressure release in the protection line occurs due to the power pressure. For each scheme, mathematical models were developed, consisting of systemsof nonlinear differential and algebraic equations. A computational analysis of the dynamic characteristics of slide valves within the three schemes wasperformed using the example designs of valves from K-160-130 and K-300-240 turbines. To evaluate dynamic performance, the turbine operatingmode during a sudden disconnection of the generator from the electrical grid was selected. The results show that the first scheme provides the bestresponse speed. The second and third schemes not only have lower response speed but also negatively affect the stability of pressure in the turbineprotection line. The use of the second scheme in systems where multiple slide valves must operate simultaneously under certain operating conditionsmay lead to an unintended turbine shutdown. In conclusion, the use of the first slide valve connection scheme is recommended. The obtained resultscan be used for the modernization of automatic control and protection systems of steam turbines when implementing electro-hydraulic control systems.
- Open Access
- 29 June 2026
- Published by Private Company Technology Center in Eastern-European Journal of Enterprise Technologies
- Vol. 3 (7 (141)) , 71-82
Development a computationally efficient method to solve direct and inverse aerodynamic problems related to turbomachines
This study investigates aerodynamic processes in interblade, axial annular, and radial-axial channels in turbomachines. The task addressed relates to the need to improve the computational efficiency in solving direct and inverse aerodynamic problems when analyzing and designing flow parts of turbomachines. A computationally efficient method for solving direct and inverse aerodynamic problems has been proposed, which provides acceptable accuracy for engineering practice at significantly lower computational costs compared to conventional CFD approaches. The results include a devised single mathematical formulation based on Euler equations for a compressible fluid, written in terms of the flow function. The proposed method makes it possible to consider direct and inverse problems within a common mathematical structure. The system of equations is reduced to a single differential equation and a set of algebraic relations while the global flow problem is decomposed into a set of independent problems for individual cross-sections. The inverse problem is stated as a nonlinear optimization problem based on the mass flow rate agreement condition derived from the energy equation. The computational complexity is reduced by using the flow function and the decomposition of the computational domain. The method combines the capabilities of direct analysis and reconstruction of the flow channel geometry based on the predefined aerodynamic characteristics. Verification by experimental data and direct calculation results demonstrated good agreement between the velocity distributions and the reconstructed geometry; the maximum deviations did not exceed 0.3%. The results could be practically applied to preliminary design, parametric optimization, as well as inverse design of the flow parts in turbomachines
- 29 June 2026
- Published by Private Company Technology Center in Eastern-European Journal of Enterprise Technologies
- Vol. 3 (7 (141)) , 71-82
Open AccessDevelopment a computationally efficient method to solve direct and inverse aerodynamic problems related to turbomachines
This study investigates aerodynamic processes in interblade, axial annular, and radial-axial channels in turbomachines. The task addressed relates to the need to improve the computational efficiency in solving direct and inverse aerodynamic problems when analyzing and designing flow parts of turbomachines. A computationally efficient method for solving direct and inverse aerodynamic problems has been proposed, which provides acceptable accuracy for engineering practice at significantly lower computational costs compared to conventional CFD approaches. The results include a devised single mathematical formulation based on Euler equations for a compressible fluid, written in terms of the flow function. The proposed method makes it possible to consider direct and inverse problems within a common mathematical structure. The system of equations is reduced to a single differential equation and a set of algebraic relations while the global flow problem is decomposed into a set of independent problems for individual cross-sections. The inverse problem is stated as a nonlinear optimization problem based on the mass flow rate agreement condition derived from the energy equation. The computational complexity is reduced by using the flow function and the decomposition of the computational domain. The method combines the capabilities of direct analysis and reconstruction of the flow channel geometry based on the predefined aerodynamic characteristics. Verification by experimental data and direct calculation results demonstrated good agreement between the velocity distributions and the reconstructed geometry; the maximum deviations did not exceed 0.3%. The results could be practically applied to preliminary design, parametric optimization, as well as inverse design of the flow parts in turbomachines
- Open Access
- 29 May 2026
- Published by National Technical University Kharkiv Polytechnic Institute in NTU "KhPI" Bulletin: Power and heat engineering processes and equipment
- No. 1,p. 5-16
Evaluation of Methods for Predicting Deviation Angle in Planar Turbine Cascades
This paper presents a review of methods for predicting the flow exit angle from a planar turbine cascade operating with subsonic and transonic flow regimes. An analysis of empirical correlations used to determine the deviation angle is performed, and the advantages and limitations of each approach are discussed. The accuracy of empirical correlations and the CFD approach is evaluated by comparing their predictions with experimental data obtained for the VKI turbine cascade profile under both design and off-design operating conditions. The comparison reveals a low prediction accuracy of empirical correlations for considered regimes. The largest discrepancies are observed at outlet Mach numbers below 0.6. The closest agreement with experimental data is achieved using CFD (AxCFD™). The results show good consistency both in terms of the absolute values of the deviation angle and the trend of its variation under off-design conditions. Additional CFD simulations of three planar turbine cascade configurations demonstrate a significant influence of blade geometry on the predicted deviation angle. The relationship between the kinetic energy loss coefficient and the deviation angle is also discussed. Both CFD and experimental results indicate that the minimum loss condition corresponds to the minimum deviation angle. Furthermore, a consistent trend in the variation of these two parameters is observed across different operating regimes. It is concluded that accurate prediction of the deviation angle is a complex problem requiring consideration of a wide range of geometric and operating parameters of the cascade. Further research in this area is recommended.
- 29 May 2026
- Published by National Technical University Kharkiv Polytechnic Institute in NTU "KhPI" Bulletin: Power and heat engineering processes and equipment
- No. 1,p. 5-16
Open AccessEvaluation of Methods for Predicting Deviation Angle in Planar Turbine Cascades
This paper presents a review of methods for predicting the flow exit angle from a planar turbine cascade operating with subsonic and transonic flow regimes. An analysis of empirical correlations used to determine the deviation angle is performed, and the advantages and limitations of each approach are discussed. The accuracy of empirical correlations and the CFD approach is evaluated by comparing their predictions with experimental data obtained for the VKI turbine cascade profile under both design and off-design operating conditions. The comparison reveals a low prediction accuracy of empirical correlations for considered regimes. The largest discrepancies are observed at outlet Mach numbers below 0.6. The closest agreement with experimental data is achieved using CFD (AxCFD™). The results show good consistency both in terms of the absolute values of the deviation angle and the trend of its variation under off-design conditions. Additional CFD simulations of three planar turbine cascade configurations demonstrate a significant influence of blade geometry on the predicted deviation angle. The relationship between the kinetic energy loss coefficient and the deviation angle is also discussed. Both CFD and experimental results indicate that the minimum loss condition corresponds to the minimum deviation angle. Furthermore, a consistent trend in the variation of these two parameters is observed across different operating regimes. It is concluded that accurate prediction of the deviation angle is a complex problem requiring consideration of a wide range of geometric and operating parameters of the cascade. Further research in this area is recommended.
- 28 December 2025
- Published by National Technical University Kharkiv Polytechnic Institute in NTU "KhPI" Bulletin: Power and heat engineering processes and equipment
- No. 2,p. 32-38
Design and Operating Modes of Stop and Control Valves of High-Power Steam Turbines
The operating modes of stop and control valves of high-pressure and intermediate-pressure (low-pressure) sections of existing steam turbines of thermal and nuclear power plants are discussed in the article. Typical operating modes of the valves are defined depending on their functional purpose within the installation, the steam distribution system, the turbine type, and the method of power control. The flow pattern in angle-type valves with one side steam supply into the steam chest is discussed. It is noted that this design is typical for use in high-power steam turbine units operated in Ukraine. As a result, a classification of stop and control valves into three groups is proposed. For each group, recommendations are provided regarding the design of the valve flow-path elements, specifically the main plug and the seat, which contribute to improving their operational efficiency. In addition, to stabilize the flow, the feasibility of installing a special cylindrical shell inside the steam chest is considered, featuring an impermeable sector oriented toward the valve inlet pipe.
- 28 December 2025
- Published by National Technical University Kharkiv Polytechnic Institute in NTU "KhPI" Bulletin: Power and heat engineering processes and equipment
- No. 2,p. 32-38
Design and Operating Modes of Stop and Control Valves of High-Power Steam Turbines
The operating modes of stop and control valves of high-pressure and intermediate-pressure (low-pressure) sections of existing steam turbines of thermal and nuclear power plants are discussed in the article. Typical operating modes of the valves are defined depending on their functional purpose within the installation, the steam distribution system, the turbine type, and the method of power control. The flow pattern in angle-type valves with one side steam supply into the steam chest is discussed. It is noted that this design is typical for use in high-power steam turbine units operated in Ukraine. As a result, a classification of stop and control valves into three groups is proposed. For each group, recommendations are provided regarding the design of the valve flow-path elements, specifically the main plug and the seat, which contribute to improving their operational efficiency. In addition, to stabilize the flow, the feasibility of installing a special cylindrical shell inside the steam chest is considered, featuring an impermeable sector oriented toward the valve inlet pipe.