Hersnastiti Sedya Utami
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Hersnastiti Sedya Utami has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Kusnanto Mukti Wibowo
Department of Medical Electronics Engineering Technology, Universitas Muhammadiyah Purwokerto, Purwokerto, Indonesia, Indonesia
2 shared publications - Arga Pratama Rahardian
Departement of Radiology Imaging Technology, Universitas Muhammadiyah Purwokerto, Banyumas, Indonesia, Indonesia
1 shared publication - Fani Susanto
Departement of Radiology Imaging Technology, Universitas Muhammadiyah Purwokerto, Banyumas, Indonesia, Indonesia
1 shared publication Mahdelia Aqiilah Bilqiis
1 shared publication- Nurul Fadhlina Binti Ismail
Department of Medical Imaging, Universiti Sultan Zainal Abidin, Malaysia, Malaysia
1 shared publication - Samudra Prihatin Hendra Basuki
Departement of Nursing, Universitas Muhammadiyah Purwokerto, Indonesia, Indonesia
1 shared publication
Latest Publications
- Open Access
- 5 April 2026
- Published by Poltekkes Kemenkes Surabaya in Indonesian Journal of electronics, electromedical engineering, and medical informatics
- Vol. 8 (2) , 275-285
Optimization of Intelligent Grid Strength and Grid Ratio to Improve Pelvic Radiographic Image Quality in Digital Radiography
Pelvic radiography is an essential diagnostic procedure; however, its image quality is often degraded by scattered radiation, which reduces contrast and diagnostic accuracy. Conventional physical grids can reduce scatter but have limitations, including increased patient dose and workflow constraints, particularly in mobile radiography. The Intelligent Grid, a digital scatter correction technology, provides a promising alternative, yet the optimal combination of grid ratio and strength parameters remains unclear. This study aims to optimize the strength and grid ratio of the Intelligent Grid to improve pelvic radiographic image quality. This study introduces a novel quantitative optimization approach that systematically integrates grid ratio and strength variations within the Intelligent Grid system to enhance pelvic radiographic image quality in digital radiography. A quantitative experimental approach with a post-test only design was conducted using a mobile X-ray system, digital radiography, an Aero DR detector, and pelvic phantoms. Data were acquired by performing anteroposterior pelvic radiography exposures (60 kV & 10 mAs) with the Intelligent Grid. Strength variations (slightly strong, normal, slightly weak) and grid ratios (3:1, 6:1, 8:1, 10:1, 12:1) were applied to generate different parameter combinations. Image quality was evaluated quantitatively (histogram and SNR) and qualitatively through visual grading by three radiologists. Statistical analysis was performed using Repeated ANOVA and Friedman tests. Statistical analysis showed significant differences (p < 0.001) in pelvic radiographic image quality across Intelligent Grid ratio and strength combinations. The 12:1 grid ratio with slightly strong strength yielded the highest mean SNR, balanced grayscale distribution, and top visual grading scores, confirming its optimal performance in enhancing image contrast and anatomical visibility of the iliac contour, acetabulum, and pubic symphysis. In conclusion, optimal adjustment of Intelligent Grid strength and grid ratio parameters can substantially improve pelvic radiographic image quality, providing a practical alternative to conventional physical grids in digital radiography
- 5 April 2026
- Published by Poltekkes Kemenkes Surabaya in Indonesian Journal of electronics, electromedical engineering, and medical informatics
- Vol. 8 (2) , 275-285
Open AccessOptimization of Intelligent Grid Strength and Grid Ratio to Improve Pelvic Radiographic Image Quality in Digital Radiography
Pelvic radiography is an essential diagnostic procedure; however, its image quality is often degraded by scattered radiation, which reduces contrast and diagnostic accuracy. Conventional physical grids can reduce scatter but have limitations, including increased patient dose and workflow constraints, particularly in mobile radiography. The Intelligent Grid, a digital scatter correction technology, provides a promising alternative, yet the optimal combination of grid ratio and strength parameters remains unclear. This study aims to optimize the strength and grid ratio of the Intelligent Grid to improve pelvic radiographic image quality. This study introduces a novel quantitative optimization approach that systematically integrates grid ratio and strength variations within the Intelligent Grid system to enhance pelvic radiographic image quality in digital radiography. A quantitative experimental approach with a post-test only design was conducted using a mobile X-ray system, digital radiography, an Aero DR detector, and pelvic phantoms. Data were acquired by performing anteroposterior pelvic radiography exposures (60 kV & 10 mAs) with the Intelligent Grid. Strength variations (slightly strong, normal, slightly weak) and grid ratios (3:1, 6:1, 8:1, 10:1, 12:1) were applied to generate different parameter combinations. Image quality was evaluated quantitatively (histogram and SNR) and qualitatively through visual grading by three radiologists. Statistical analysis was performed using Repeated ANOVA and Friedman tests. Statistical analysis showed significant differences (p < 0.001) in pelvic radiographic image quality across Intelligent Grid ratio and strength combinations. The 12:1 grid ratio with slightly strong strength yielded the highest mean SNR, balanced grayscale distribution, and top visual grading scores, confirming its optimal performance in enhancing image contrast and anatomical visibility of the iliac contour, acetabulum, and pubic symphysis. In conclusion, optimal adjustment of Intelligent Grid strength and grid ratio parameters can substantially improve pelvic radiographic image quality, providing a practical alternative to conventional physical grids in digital radiography
- Open Access
- 23 December 2025
- Published by Center for Journal Management and Publication, Lambung Mangkurat University in Jurnal Fisika Flux: Jurnal Ilmiah Fisika FMIPA Universitas Lambung Mangkurat
- Vol. 23 (1) , 78
Analisis Korelasi Berat Badan dengan Size Spesific Dose Estimate dan Dosis Efektif pada CT Scan Abdomen
- 23 December 2025
- Published by Center for Journal Management and Publication, Lambung Mangkurat University in Jurnal Fisika Flux: Jurnal Ilmiah Fisika FMIPA Universitas Lambung Mangkurat
- Vol. 23 (1) , 78
Open AccessAnalisis Korelasi Berat Badan dengan Size Spesific Dose Estimate dan Dosis Efektif pada CT Scan Abdomen