FSFani Susanto

Fani Susanto

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Fani Susanto has a total of 8 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Experimental Study on Thickness-Dependent X-ray Radiation Protection of a Flexible and Lightweight Silicone Rubber–PbO Composite Apron

    by Fathur Rahman Nugraha, Kusnanto Mukti Wibowo, Arga Pratama Rahardian, Fani Susanto, Supriyadi Supriyadi

    The use of X-rays in medical imaging provides substantial diagnostic benefits but also poses risks associated with ionizing radiation exposure. Conventional lead-based protective aprons are effective but have major limitations, including excessive weight, rigidity, and potential toxicity. This study addresses a specific research gap by systematically evaluating the relationship between material thickness, radiation attenuation effectiveness, and the Half-Value Layer (HVL) of silicone rubber-based aprons filled with lead(II) oxide (PbO) at clinically relevant low-to-medium X-ray energies. An experimental method was employed by fabricating silicone–PbO composite apron prototypes with three thickness variations (2.5 mm, 3.0 mm, and 3.5 mm). Radiation attenuation tests were conducted at X-ray tube voltages of 60, 65, and 70 kV by measuring radiation intensity before and after transmission through the samples using a radiation detector, followed by calculating protection effectiveness and HVL values. The results demonstrate that apron thickness significantly influences radiation protection performance, with the highest attenuation of 85.11% achieved at a thickness of 3.5 mm. A moderate-to-strong positive correlation between thickness and protection effectiveness is observed at all voltage levels, with the highest coefficient of determination (R² = 0.916) at 65 kV. HVL values increase with thickness, indicating the need for thicker materials to achieve a 50% reduction in radiation intensity at higher attenuation levels. These findings highlight the novelty of quantitatively correlating thickness, attenuation effectiveness, and HVL within a single experimental framework and demonstrate that silicone rubber–PbO composite aprons have strong potential as a lightweight and flexible alternative to conventional lead aprons for clinical radiation protection at low-to-medium diagnostic X-ray energies.


  • Open Access

    Optimization of Intelligent Grid Strength and Grid Ratio to Improve Pelvic Radiographic Image Quality in Digital Radiography

    by Fani Susanto, Hernastiti Sedya Utami, Kusnanto Mukti Wibowo, Samudra Prihatin Hendra Basuki, Widya Mufida, Nurul Fadhlina Binti Ismail

    Pelvic radiography is an essential diagnostic procedure; however, its image quality is often degraded by scattered radiation, which reduces contrast and diagnostic accuracy. Conventional physical grids can reduce scatter but have limitations, including increased patient dose and workflow constraints, particularly in mobile radiography. The Intelligent Grid, a digital scatter correction technology, provides a promising alternative, yet the optimal combination of grid ratio and strength parameters remains unclear. This study aims to optimize the strength and grid ratio of the Intelligent Grid to improve pelvic radiographic image quality. This study introduces a novel quantitative optimization approach that systematically integrates grid ratio and strength variations within the Intelligent Grid system to enhance pelvic radiographic image quality in digital radiography. A quantitative experimental approach with a post-test only design was conducted using a mobile X-ray system, digital radiography, an Aero DR detector, and pelvic phantoms. Data were acquired by performing anteroposterior pelvic radiography exposures (60 kV & 10 mAs) with the Intelligent Grid. Strength variations (slightly strong, normal, slightly weak) and grid ratios (3:1, 6:1, 8:1, 10:1, 12:1) were applied to generate different parameter combinations. Image quality was evaluated quantitatively (histogram and SNR) and qualitatively through visual grading by three radiologists. Statistical analysis was performed using Repeated ANOVA and Friedman tests. Statistical analysis showed significant differences (p < 0.001) in pelvic radiographic image quality across Intelligent Grid ratio and strength combinations. The 12:1 grid ratio with slightly strong strength yielded the highest mean SNR, balanced grayscale distribution, and top visual grading scores, confirming its optimal performance in enhancing image contrast and anatomical visibility of the iliac contour, acetabulum, and pubic symphysis. In conclusion, optimal adjustment of Intelligent Grid strength and grid ratio parameters can substantially improve pelvic radiographic image quality, providing a practical alternative to conventional physical grids in digital radiography