International Journal of Advances in Electrical Engineering
Published by AkiNik Publications
- Scilit
- Power Systems & Electric Vehicles
Publications Analysis
Publications in 2016-2026
Open Access Publications in 2016-2026
- Total Citations
- 7
- Total Publications
- 34
- Average Citations
- 0.21
- Cited Publications
- 5
- Cited Publications %
- 14.7%
- Self Citations
- 0
- Self Citations %
- 0%
- h5_index
- 3
- Monthly Citation Metric (MCM)
- 0.3
- Q1
- 0
- Med
- 0
- Q3
- 1
- 99%
- 5.3
- Max
- 6
- Citing Source Titles
- Citing Publishers
Latest Publications
- 1 July 2026
- Published by AkiNik Publications in International Journal of Advances in Electrical Engineering
- Vol. 7 (2) , 77-87
AI-based dust-aware hybrid visible light/RF communication system for reliable smart industrial environments
Visible light communications (VLC) have the potential to offer high-capacity, unlicensed wireless communication capabilities, and may provide a viable alternative or supplement to traditional RF-based technologies in smart industrial environments. However, the reliability of VLC in practice can be impacted by line-of-sight obstructions, orientation of receivers, movement of devices, airborne dust, and dust on the surface of optical components. This research presents a dust aware hybrid VLC/RF wireless communications architecture that uses artificial intelligence to achieve high levels of reliability in industrial wireless communication. A dynamic VLC channel model incorporates Lambertian propagation, airborne dust extinction, deposited dust transmission losses, orientation of receivers, device movement, and short-term obstructions into a single dynamic model, while a complementary RF channel serves as a backup to maintain connectivity. A gated recurrent unit (GRU) is trained to predict whether the VLC service will experience an outage in 0.5 seconds based upon previous communications and environmental data. This prediction is then utilized by a Dust Aware Predictive Link Selection (DAPLS) controller with hysteresis and dwell time constraints. Phase 9 final simulations demonstrate an overall outage probability of 3.2% compared to 22% for VLC only, 9% for threshold-based hybrid switching, and 6% for dust unaware GRU-DAPLS. Overall, the proposed system provides 96.8% availability, an average goodput of 25 Mbit/s, 1.5 handovers per minute, and uses VLC during 62% of all communication intervals evaluated. The inclusion of explicit dust features results in increases in recall from 0.889 to 0.919, F1 score from 0.879 to 0.915, and ROC-AUC from 0.939 to 0.960 as compared to the blockage aware predictor. An independently retrained prediction horizon study identifies 0.5 seconds as the optimal tested operating point with 0.915 recall and 3.5% overall outage. Validation at the trajectory level across eight independent test trajectories verifies statistically significant improvements in outage, goodput, handover rates, recall, F1 scores, and ROC-AUC; all nine exact two-sided sign flip tests resulted in p = 0.0078, and all 95% bootstrap confidence intervals excluded zero.
- 1 July 2026
- Published by AkiNik Publications in International Journal of Advances in Electrical Engineering
- Vol. 7 (2) , 77-87
AI-based dust-aware hybrid visible light/RF communication system for reliable smart industrial environments
Visible light communications (VLC) have the potential to offer high-capacity, unlicensed wireless communication capabilities, and may provide a viable alternative or supplement to traditional RF-based technologies in smart industrial environments. However, the reliability of VLC in practice can be impacted by line-of-sight obstructions, orientation of receivers, movement of devices, airborne dust, and dust on the surface of optical components. This research presents a dust aware hybrid VLC/RF wireless communications architecture that uses artificial intelligence to achieve high levels of reliability in industrial wireless communication. A dynamic VLC channel model incorporates Lambertian propagation, airborne dust extinction, deposited dust transmission losses, orientation of receivers, device movement, and short-term obstructions into a single dynamic model, while a complementary RF channel serves as a backup to maintain connectivity. A gated recurrent unit (GRU) is trained to predict whether the VLC service will experience an outage in 0.5 seconds based upon previous communications and environmental data. This prediction is then utilized by a Dust Aware Predictive Link Selection (DAPLS) controller with hysteresis and dwell time constraints. Phase 9 final simulations demonstrate an overall outage probability of 3.2% compared to 22% for VLC only, 9% for threshold-based hybrid switching, and 6% for dust unaware GRU-DAPLS. Overall, the proposed system provides 96.8% availability, an average goodput of 25 Mbit/s, 1.5 handovers per minute, and uses VLC during 62% of all communication intervals evaluated. The inclusion of explicit dust features results in increases in recall from 0.889 to 0.919, F1 score from 0.879 to 0.915, and ROC-AUC from 0.939 to 0.960 as compared to the blockage aware predictor. An independently retrained prediction horizon study identifies 0.5 seconds as the optimal tested operating point with 0.915 recall and 3.5% overall outage. Validation at the trajectory level across eight independent test trajectories verifies statistically significant improvements in outage, goodput, handover rates, recall, F1 scores, and ROC-AUC; all nine exact two-sided sign flip tests resulted in p = 0.0078, and all 95% bootstrap confidence intervals excluded zero.
- Open Access
- 1 July 2026
- Published by AkiNik Publications in International Journal of Advances in Electrical Engineering
- Vol. 7 (2) , 71-76
A comprehensive quantitative comparative analysis of magnetic levitation (Maglev) trains and conventional electric high-speed rail systems
This research paper presents a quantitative comparative evaluation of magnetic levitation (maglev) trains and conventional electric high-speed rail (HSR) systems. Maglev employs electromagnetic or electrodynamics’ forces for contactless levitation, guidance, and propulsion. Conventional electric trains use steel wheels on steel rails with rotary traction motors powered by overhead catenary systems. The analysis incorporates mathematical models of resistance forces (Davis equation and maglev-specific variants), energy consumption formulas, travel-time calculations, specific energy metrics (Wh/seat-km and Wh/m2·km), capital and operational cost estimates, and sample numerical computations for representative corridors. Key quantitative findings show that maglev achieves higher peak speeds (commercial up to 431 km/h, tested 603 km/h) and lower mechanical resistance, while conventional HSR offers lower capital costs (typically US$17–45 million/km versus significantly higher for maglev) and competitive energy use at 300–350 km/h. Energy demand is dominated by aerodynamic drag (proportional to v2) for both systems above approximately 250 km/h. Maglev demonstrates slight energy advantages under certain normalized conditions up to the design speeds of conventional systems, but absolute consumption rises sharply at 430–500 km/h.
- 1 July 2026
- Published by AkiNik Publications in International Journal of Advances in Electrical Engineering
- Vol. 7 (2) , 71-76
Open AccessA comprehensive quantitative comparative analysis of magnetic levitation (Maglev) trains and conventional electric high-speed rail systems
This research paper presents a quantitative comparative evaluation of magnetic levitation (maglev) trains and conventional electric high-speed rail (HSR) systems. Maglev employs electromagnetic or electrodynamics’ forces for contactless levitation, guidance, and propulsion. Conventional electric trains use steel wheels on steel rails with rotary traction motors powered by overhead catenary systems. The analysis incorporates mathematical models of resistance forces (Davis equation and maglev-specific variants), energy consumption formulas, travel-time calculations, specific energy metrics (Wh/seat-km and Wh/m2·km), capital and operational cost estimates, and sample numerical computations for representative corridors. Key quantitative findings show that maglev achieves higher peak speeds (commercial up to 431 km/h, tested 603 km/h) and lower mechanical resistance, while conventional HSR offers lower capital costs (typically US$17–45 million/km versus significantly higher for maglev) and competitive energy use at 300–350 km/h. Energy demand is dominated by aerodynamic drag (proportional to v2) for both systems above approximately 250 km/h. Maglev demonstrates slight energy advantages under certain normalized conditions up to the design speeds of conventional systems, but absolute consumption rises sharply at 430–500 km/h.
- Open Access
- 1 July 2026
- Published by AkiNik Publications in International Journal of Advances in Electrical Engineering
- Vol. 7 (2) , 62-70
Performance enhancement and low-irradiance ride-through of hardware-based PV voltage transition units using supercapacitor auxiliary buffers
In the case of rapid partial shading transients, hardware-based Photovoltaic (PV) array reconfiguration architectures often need to deal with control instability and power supply collapse due dropping internal auxiliary voltages ( V_{CC} VCC) (Ghazi et al., 2021) 2. In order to mitigate this bottleneck, a self-powered Optimizing Transition Unit (OTU) is proposed in this paper helping guarantee low irradiance ride-through capability without the aid of external auxiliary supply. The presented OTU features a Schottky diode OR-ing network ( Vf≈0.25 V Vf≈0.25 V) coupled to a 0.5\text{~F} 0.5 F supercapacitor energy buffer, which ensures that control sensing does not interrupt the function of controlling feeding. The proposed system topology and its dynamic behavior were modeled & validated under highly variable shading situations using MATLAB/Simulink. Simulation results show that the proposed OTU successfully delivers a hold-up time of 12.8s during complete shading events, completely inhibiting control lock up and relay chattering. Additionally, the logic transition ability to mitigate under dynamic partial shading boosts overall PV energy extraction 16.4% relative to traditional unbuffered hardware topologies the proposed unit provides a low-cost, high-reliability self-sustaining solution for solar array reconfiguration.
- 1 July 2026
- Published by AkiNik Publications in International Journal of Advances in Electrical Engineering
- Vol. 7 (2) , 62-70
Open AccessPerformance enhancement and low-irradiance ride-through of hardware-based PV voltage transition units using supercapacitor auxiliary buffers
In the case of rapid partial shading transients, hardware-based Photovoltaic (PV) array reconfiguration architectures often need to deal with control instability and power supply collapse due dropping internal auxiliary voltages ( V_{CC} VCC) (Ghazi et al., 2021) 2. In order to mitigate this bottleneck, a self-powered Optimizing Transition Unit (OTU) is proposed in this paper helping guarantee low irradiance ride-through capability without the aid of external auxiliary supply. The presented OTU features a Schottky diode OR-ing network ( Vf≈0.25 V Vf≈0.25 V) coupled to a 0.5\text{~F} 0.5 F supercapacitor energy buffer, which ensures that control sensing does not interrupt the function of controlling feeding. The proposed system topology and its dynamic behavior were modeled & validated under highly variable shading situations using MATLAB/Simulink. Simulation results show that the proposed OTU successfully delivers a hold-up time of 12.8s during complete shading events, completely inhibiting control lock up and relay chattering. Additionally, the logic transition ability to mitigate under dynamic partial shading boosts overall PV energy extraction 16.4% relative to traditional unbuffered hardware topologies the proposed unit provides a low-cost, high-reliability self-sustaining solution for solar array reconfiguration.
- Open Access
- 1 July 2026
- Published by AkiNik Publications in International Journal of Advances in Electrical Engineering
- Vol. 7 (2) , 57-61
Influence of cable tray fill ratio and tray material on ampacity derating of low-voltage power cables under sustained overload conditions
Overloaded cable trays in industrial facilities remain one of the most common but least quantified causes of insulation degradation in low-voltage power cables, because existing derating tables in IEC 60364-5-52 and NEC Article 392 assume steady-state thermal equilibrium and do not account for the interaction between fill ratio, tray material, and sustained overload duration. This research measured conductor temperatures in five tray material configurations aluminium ladder, steel ladder, aluminium solid-bottom, steel solid-bottom, and fibre-reinforced polymer (FRP) solid-bottom at five fill ratios (20%, 30%, 40%, 50%, and 60%) under a sustained 125% overload lasting 72 hours. Twenty-five test configurations were each instrumented with 12 thermocouples distributed along a 3 m tray section at the Basque University of Electrical Sciences, Bilbao, Spain, between February and October 2024. The measured derating factor ranged from 0.97 at 20% fill in an aluminium ladder tray to 0.49 at 60% fill in an FRP solid-bottom tray. Ladder trays outperformed solid-bottom trays by 8-25 percentage points at the same fill ratio, and aluminium trays provided a 2-5 percentage-point advantage over steel owing to their higher thermal conductivity. The FRP solid-bottom tray produced the most severe derating at every fill ratio, reaching conductor temperatures 23.7 °C above the aluminium ladder configuration at 60% fill. These experimentally derived derating factors were 6-18% more conservative than the tabulated values in IEC 60364-5-52, indicating that standard tables may underestimate the thermal penalty of high fill ratios under sustained overload.
- 1 July 2026
- Published by AkiNik Publications in International Journal of Advances in Electrical Engineering
- Vol. 7 (2) , 57-61
Open AccessInfluence of cable tray fill ratio and tray material on ampacity derating of low-voltage power cables under sustained overload conditions
Overloaded cable trays in industrial facilities remain one of the most common but least quantified causes of insulation degradation in low-voltage power cables, because existing derating tables in IEC 60364-5-52 and NEC Article 392 assume steady-state thermal equilibrium and do not account for the interaction between fill ratio, tray material, and sustained overload duration. This research measured conductor temperatures in five tray material configurations aluminium ladder, steel ladder, aluminium solid-bottom, steel solid-bottom, and fibre-reinforced polymer (FRP) solid-bottom at five fill ratios (20%, 30%, 40%, 50%, and 60%) under a sustained 125% overload lasting 72 hours. Twenty-five test configurations were each instrumented with 12 thermocouples distributed along a 3 m tray section at the Basque University of Electrical Sciences, Bilbao, Spain, between February and October 2024. The measured derating factor ranged from 0.97 at 20% fill in an aluminium ladder tray to 0.49 at 60% fill in an FRP solid-bottom tray. Ladder trays outperformed solid-bottom trays by 8-25 percentage points at the same fill ratio, and aluminium trays provided a 2-5 percentage-point advantage over steel owing to their higher thermal conductivity. The FRP solid-bottom tray produced the most severe derating at every fill ratio, reaching conductor temperatures 23.7 °C above the aluminium ladder configuration at 60% fill. These experimentally derived derating factors were 6-18% more conservative than the tabulated values in IEC 60364-5-52, indicating that standard tables may underestimate the thermal penalty of high fill ratios under sustained overload.
- Open Access
- 1 July 2026
- Published by AkiNik Publications in International Journal of Advances in Electrical Engineering
- Vol. 7 (2) , 50-56
Thermal runaway prediction in gapless metal-oxide surge arresters using real-time resistive leakage current waveform monitoring with embedded microcontrollers
The first gapless metal-oxide varistor surge arresters entered service on transmission networks in the late 1970s, and within a decade field reports of thermal runaway failures had prompted a wave of research into condition monitoring techniques based on leakage current analysis. Yet nearly five decades later, the real-time prediction of thermal runaway from continuous resistive leakage current waveforms as opposed to periodic offline measurements remains an unsolved deployment problem for most utilities. This research developed and validated an embedded microcontroller platform that extracts the resistive component of leakage current in real time using a phase-resolved digital signal processing algorithm, feeds the extracted waveform into a lumped-parameter thermal model of the arrester body, and predicts the time to thermal runaway with a mean lead time of 6.4 hours. Eighteen 72 kV, 10 kA gapless metal-oxide surge arresters six new, six artificially aged through 1,000 impulse applications, and six intentionally degraded by moisture ingress were subjected to accelerated thermal stress in a climate chamber at the Linz Research Institute, Austria, between January and July 2024. The embedded platform, built around an ARM Cortex-M4 microcontroller with a 16-bit ADC sampling at 25.6 kS/s, computed the resistive current component every 200 ms and updated the thermal prediction every 60 s. Across 54 accelerated runaway tests, the platform correctly predicted all 18 runaway events in the degraded group with a mean lead time of 6.4 ± 1.3 hours and generated zero false alarms in the 36 tests on new and aged arresters that did not reach runaway. The resistive leakage current at the prediction trigger point averaged 89.7 µA for degraded units, compared with 33.2 µA for new and 52.4 µA for aged arresters at the same body temperature. These results show that a low-cost microcontroller platform can deliver actionable thermal runaway warnings with enough lead time for utility operators to de-energize and replace the arrester before failure.
- 1 July 2026
- Published by AkiNik Publications in International Journal of Advances in Electrical Engineering
- Vol. 7 (2) , 50-56
Open AccessThermal runaway prediction in gapless metal-oxide surge arresters using real-time resistive leakage current waveform monitoring with embedded microcontrollers
The first gapless metal-oxide varistor surge arresters entered service on transmission networks in the late 1970s, and within a decade field reports of thermal runaway failures had prompted a wave of research into condition monitoring techniques based on leakage current analysis. Yet nearly five decades later, the real-time prediction of thermal runaway from continuous resistive leakage current waveforms as opposed to periodic offline measurements remains an unsolved deployment problem for most utilities. This research developed and validated an embedded microcontroller platform that extracts the resistive component of leakage current in real time using a phase-resolved digital signal processing algorithm, feeds the extracted waveform into a lumped-parameter thermal model of the arrester body, and predicts the time to thermal runaway with a mean lead time of 6.4 hours. Eighteen 72 kV, 10 kA gapless metal-oxide surge arresters six new, six artificially aged through 1,000 impulse applications, and six intentionally degraded by moisture ingress were subjected to accelerated thermal stress in a climate chamber at the Linz Research Institute, Austria, between January and July 2024. The embedded platform, built around an ARM Cortex-M4 microcontroller with a 16-bit ADC sampling at 25.6 kS/s, computed the resistive current component every 200 ms and updated the thermal prediction every 60 s. Across 54 accelerated runaway tests, the platform correctly predicted all 18 runaway events in the degraded group with a mean lead time of 6.4 ± 1.3 hours and generated zero false alarms in the 36 tests on new and aged arresters that did not reach runaway. The resistive leakage current at the prediction trigger point averaged 89.7 µA for degraded units, compared with 33.2 µA for new and 52.4 µA for aged arresters at the same body temperature. These results show that a low-cost microcontroller platform can deliver actionable thermal runaway warnings with enough lead time for utility operators to de-energize and replace the arrester before failure.
- Open Access
- 1 July 2026
- Published by AkiNik Publications in International Journal of Advances in Electrical Engineering
- Vol. 7 (2) , 45-49
Impact of distributed single-phase rooftop solar inverter clusters on negative sequence voltage and neutral conductor loading in low-voltage distribution feeders
Unbalanced single-phase solar generation is already the dominant source of negative sequence voltage in many residential low-voltage networks, yet the quantitative relationship between rooftop photovoltaic penetration and neutral conductor thermal loading remains poorly mapped under field conditions. This research measured voltage unbalance factor and neutral current on two 400 V feeders in Wollongong, Australia, across fifteen progressive solar penetration levels ranging from 6% to 92% of transformer rating. A three-month monitoring campaign between June and August 2024 captured 10-minute averaged data from power quality recorders installed at the transformer secondary and at three downstream nodes on each feeder. The voltage unbalance factor exceeded the 2% limit specified by AS/NZS 61000.2.2 at solar penetration above 72% on Feeder A and above 64% on Feeder B, where inverter allocation was more asymmetric. Neutral conductor current reached 68.3% of phase conductor rating at 92% penetration on Feeder B, raising the joule loss in the neutral by a factor of 4.7 relative to the no-solar baseline. A strong linear correlation (r = 0.989 to 0.993, P < 0.001) was found between solar penetration and voltage unbalance factor on both feeders. Results show that phase-balancing controls embedded in smart inverter firmware can hold the voltage unbalance factor below 1.2% up to 85% penetration, provided no single phase carries more than 40% of the total installed capacity.
- 1 July 2026
- Published by AkiNik Publications in International Journal of Advances in Electrical Engineering
- Vol. 7 (2) , 45-49
Open AccessImpact of distributed single-phase rooftop solar inverter clusters on negative sequence voltage and neutral conductor loading in low-voltage distribution feeders
Unbalanced single-phase solar generation is already the dominant source of negative sequence voltage in many residential low-voltage networks, yet the quantitative relationship between rooftop photovoltaic penetration and neutral conductor thermal loading remains poorly mapped under field conditions. This research measured voltage unbalance factor and neutral current on two 400 V feeders in Wollongong, Australia, across fifteen progressive solar penetration levels ranging from 6% to 92% of transformer rating. A three-month monitoring campaign between June and August 2024 captured 10-minute averaged data from power quality recorders installed at the transformer secondary and at three downstream nodes on each feeder. The voltage unbalance factor exceeded the 2% limit specified by AS/NZS 61000.2.2 at solar penetration above 72% on Feeder A and above 64% on Feeder B, where inverter allocation was more asymmetric. Neutral conductor current reached 68.3% of phase conductor rating at 92% penetration on Feeder B, raising the joule loss in the neutral by a factor of 4.7 relative to the no-solar baseline. A strong linear correlation (r = 0.989 to 0.993, P < 0.001) was found between solar penetration and voltage unbalance factor on both feeders. Results show that phase-balancing controls embedded in smart inverter firmware can hold the voltage unbalance factor below 1.2% up to 85% penetration, provided no single phase carries more than 40% of the total installed capacity.
- Open Access
- 1 July 2026
- Published by AkiNik Publications in International Journal of Advances in Electrical Engineering
- Vol. 7 (2) , 39-44
Transient recovery voltage stress analysis on vacuum circuit breakers during back-to-back capacitor bank switching in industrial power systems
Approximately 37% of vacuum circuit breaker failures in medium-voltage industrial plants can be traced to transient recovery voltage events linked to capacitor bank switching, yet the specific TRV stress profiles generated during back-to-back operations remain only partially quantified under field-representative conditions. This research evaluated TRV waveforms across vacuum circuit breakers during back-to-back capacitor bank switching at five voltage levels (4.16, 6.6, 11, 13.8, and 22 kV) and six bank ratings (200-1200 kVAr) in a controlled industrial test facility at the Campinas Institute of Electrical Engineering, Brazil. A 14-bit digitizer sampling at 50 MS/s captured the voltage across the breaker contacts during 720 switching events performed between April 2023 and January 2024. Each TRV waveform was characterized by its peak magnitude, rate of voltage rise, time to peak, and oscillation frequency, and then compared against the IEC 62271-100 standardized TRV envelope for the corresponding duty class. Results showed that 15.2% of all back-to-back switching events produced TRV peaks exceeding the IEC envelope, with the highest exceedances occurring at 22 kV when a 1200 kVAr bank was switched onto a bus where a 600 kVAr bank was already energized. The rate of voltage rise reached 2.74 kV/µs in the worst case, 1.83 times the IEC T10 limit for that voltage class. A further 21.8% of events fell in a marginal zone between 90% and 100% of the envelope, meaning that more than a third of all back-to-back operations placed the breaker under significant dielectric stress. Inserting a 12 µH pre-insertion reactor between the bus and the second bank reduced the TRV peak by 41.3% and brought 94.7% of events within the IEC envelope. The oscillation frequency of the TRV waveform was strongly governed by the capacitance ratio between the energized and incoming banks, ranging from 4.8 kHz at a 1:1 ratio to 11.7 kHz at a 1:6 ratio. These findings supply quantitative guidance for industrial plant engineers selecting vacuum circuit breakers, sizing pre-insertion devices, and evaluating the dielectric risk of back-to-back capacitor bank configurations.
- 1 July 2026
- Published by AkiNik Publications in International Journal of Advances in Electrical Engineering
- Vol. 7 (2) , 39-44
Open AccessTransient recovery voltage stress analysis on vacuum circuit breakers during back-to-back capacitor bank switching in industrial power systems
Approximately 37% of vacuum circuit breaker failures in medium-voltage industrial plants can be traced to transient recovery voltage events linked to capacitor bank switching, yet the specific TRV stress profiles generated during back-to-back operations remain only partially quantified under field-representative conditions. This research evaluated TRV waveforms across vacuum circuit breakers during back-to-back capacitor bank switching at five voltage levels (4.16, 6.6, 11, 13.8, and 22 kV) and six bank ratings (200-1200 kVAr) in a controlled industrial test facility at the Campinas Institute of Electrical Engineering, Brazil. A 14-bit digitizer sampling at 50 MS/s captured the voltage across the breaker contacts during 720 switching events performed between April 2023 and January 2024. Each TRV waveform was characterized by its peak magnitude, rate of voltage rise, time to peak, and oscillation frequency, and then compared against the IEC 62271-100 standardized TRV envelope for the corresponding duty class. Results showed that 15.2% of all back-to-back switching events produced TRV peaks exceeding the IEC envelope, with the highest exceedances occurring at 22 kV when a 1200 kVAr bank was switched onto a bus where a 600 kVAr bank was already energized. The rate of voltage rise reached 2.74 kV/µs in the worst case, 1.83 times the IEC T10 limit for that voltage class. A further 21.8% of events fell in a marginal zone between 90% and 100% of the envelope, meaning that more than a third of all back-to-back operations placed the breaker under significant dielectric stress. Inserting a 12 µH pre-insertion reactor between the bus and the second bank reduced the TRV peak by 41.3% and brought 94.7% of events within the IEC envelope. The oscillation frequency of the TRV waveform was strongly governed by the capacitance ratio between the energized and incoming banks, ranging from 4.8 kHz at a 1:1 ratio to 11.7 kHz at a 1:6 ratio. These findings supply quantitative guidance for industrial plant engineers selecting vacuum circuit breakers, sizing pre-insertion devices, and evaluating the dielectric risk of back-to-back capacitor bank configurations.
- Open Access
- 1 July 2026
- Published by AkiNik Publications in International Journal of Advances in Electrical Engineering
- Vol. 7 (2) , 33-38
Inrush current characterization and sympathetic interaction in parallel-connected amorphous core distribution transformers
What happens when two amorphous core distribution transformers are energized in parallel, and how does the inrush transient in one unit provoke a sympathetic response in the other? This research addressed both questions through controlled laboratory measurements on two 250 kVA, 11/0.433 kV amorphous metal distribution transformers connected to a common 11 kV bus. Five switching configurations were examined: individual energization of each transformer, simultaneous parallel energization, sequential parallel energization with a 200 ms stagger, and sequential energization under partial resistive load. A 16-bit, 10 kS/s data acquisition platform captured instantaneous phase currents at the primary terminals, and a residual flux estimation procedure preceded each test. Peak inrush magnitudes reached 12.68 A (5.07 per-unit) during simultaneous parallel switching, exceeding single-unit peaks by 49.8%. Sympathetic interaction currents in the already-connected transformer peaked at 5.73 A and persisted for 1.87 s, roughly three times the single-unit decay constant. Staggering the closure by 200 ms lowered the sympathetic peak to 3.89 A, a 32.1% reduction, while partial loading before the second unit joined cut it to 2.14 A. Waveform analysis showed that the sympathetic current contained a pronounced second-harmonic component, reaching 38.4% of the peak, which may interfere with harmonic-restrained differential protection. Results point to sequential energization under load as the preferred switching strategy for parallel amorphous core transformers on distribution feeders. These outcomes hold practical value for utility protection engineers designing relay settings and switching procedures in networks that increasingly deploy amorphous core units for their lower no-load losses.
- 1 July 2026
- Published by AkiNik Publications in International Journal of Advances in Electrical Engineering
- Vol. 7 (2) , 33-38
Open AccessInrush current characterization and sympathetic interaction in parallel-connected amorphous core distribution transformers
What happens when two amorphous core distribution transformers are energized in parallel, and how does the inrush transient in one unit provoke a sympathetic response in the other? This research addressed both questions through controlled laboratory measurements on two 250 kVA, 11/0.433 kV amorphous metal distribution transformers connected to a common 11 kV bus. Five switching configurations were examined: individual energization of each transformer, simultaneous parallel energization, sequential parallel energization with a 200 ms stagger, and sequential energization under partial resistive load. A 16-bit, 10 kS/s data acquisition platform captured instantaneous phase currents at the primary terminals, and a residual flux estimation procedure preceded each test. Peak inrush magnitudes reached 12.68 A (5.07 per-unit) during simultaneous parallel switching, exceeding single-unit peaks by 49.8%. Sympathetic interaction currents in the already-connected transformer peaked at 5.73 A and persisted for 1.87 s, roughly three times the single-unit decay constant. Staggering the closure by 200 ms lowered the sympathetic peak to 3.89 A, a 32.1% reduction, while partial loading before the second unit joined cut it to 2.14 A. Waveform analysis showed that the sympathetic current contained a pronounced second-harmonic component, reaching 38.4% of the peak, which may interfere with harmonic-restrained differential protection. Results point to sequential energization under load as the preferred switching strategy for parallel amorphous core transformers on distribution feeders. These outcomes hold practical value for utility protection engineers designing relay settings and switching procedures in networks that increasingly deploy amorphous core units for their lower no-load losses.
- Open Access
- 1 July 2026
- Published by AkiNik Publications in International Journal of Advances in Electrical Engineering
- Vol. 7 (2) , 28-32
Magnetostriction-induced acoustic noise characterization of grain-oriented electrical steel laminations under DC-biased magnetization from nearby HVDC converter operation
Leading experts in transformer noise control have long warned that the acoustic impact of DC bias from HVDC converters on nearby AC transformers is more severe than the magnetizing current increase alone would suggest, because the asymmetric flux excursion activates magnetostrictive strain at even harmonics of the power frequency that the unbiased core does not produce. This research measured the A-weighted acoustic noise emitted by single-sheet and stacked-core samples of three grain-oriented electrical steel grades conventional grain-oriented (CGO), high-permeability (HiB), and domain-refined under controlled DC bias levels from 0 to 20 A/m at the Coimbra Foundation for Electromagnetic Research, Portugal, between March and October 2024. A total of 240 measurement points (3 grades × 10 DC bias levels × 8 repetitions) were captured in an anechoic chamber using a calibrated sound level meter at 0.3 m from the sample surface. The noise level rose from 38.2 dBA at zero bias to 82.1 dBA at 20 A/m for HiB steel, from 41.6 to 96.3 dBA for CGO, and from 36.4 to 70.4 dBA for domain-refined material. The WHO night-time noise guideline of 55 dBA was exceeded at DC bias levels of 8 A/m (CGO), 10 A/m (HiB), and 15 A/m (domain-refined). Domain-refined steel produced 14-26 dBA less noise than CGO across all bias levels, confirming its suitability for transformers installed near HVDC converter stations. The dominant noise frequency shifted from 100 Hz (second harmonic of 50 Hz) at zero bias to a broader spectrum including 50 Hz and 150 Hz components under DC bias, consistent with the excitation of odd-order magnetostrictive strain by the asymmetric flux waveform.
- 1 July 2026
- Published by AkiNik Publications in International Journal of Advances in Electrical Engineering
- Vol. 7 (2) , 28-32
Open AccessMagnetostriction-induced acoustic noise characterization of grain-oriented electrical steel laminations under DC-biased magnetization from nearby HVDC converter operation
Leading experts in transformer noise control have long warned that the acoustic impact of DC bias from HVDC converters on nearby AC transformers is more severe than the magnetizing current increase alone would suggest, because the asymmetric flux excursion activates magnetostrictive strain at even harmonics of the power frequency that the unbiased core does not produce. This research measured the A-weighted acoustic noise emitted by single-sheet and stacked-core samples of three grain-oriented electrical steel grades conventional grain-oriented (CGO), high-permeability (HiB), and domain-refined under controlled DC bias levels from 0 to 20 A/m at the Coimbra Foundation for Electromagnetic Research, Portugal, between March and October 2024. A total of 240 measurement points (3 grades × 10 DC bias levels × 8 repetitions) were captured in an anechoic chamber using a calibrated sound level meter at 0.3 m from the sample surface. The noise level rose from 38.2 dBA at zero bias to 82.1 dBA at 20 A/m for HiB steel, from 41.6 to 96.3 dBA for CGO, and from 36.4 to 70.4 dBA for domain-refined material. The WHO night-time noise guideline of 55 dBA was exceeded at DC bias levels of 8 A/m (CGO), 10 A/m (HiB), and 15 A/m (domain-refined). Domain-refined steel produced 14-26 dBA less noise than CGO across all bias levels, confirming its suitability for transformers installed near HVDC converter stations. The dominant noise frequency shifted from 100 Hz (second harmonic of 50 Hz) at zero bias to a broader spectrum including 50 Hz and 150 Hz components under DC bias, consistent with the excitation of odd-order magnetostrictive strain by the asymmetric flux waveform.
- Open Access
- 1 July 2026
- Published by AkiNik Publications in International Journal of Advances in Electrical Engineering
- Vol. 7 (2) , 23-27
Comparative performance of digital and analog governor controllers for frequency stabilization during load rejection in small-scale run-of-river hydroelectric generators
While large hydroelectric stations have long relied on digital governor systems for turbine speed control, small-scale run-of-river plants below 5 MW overwhelmingly retain analog electronic or mechanical-hydraulic governors and the performance gap between these legacy controllers and modern digital alternatives during load rejection transients has not been quantified through side-by-side field testing. This research compared a digital PID governor and an analog electronic governor on the same 1.8 MW Francis turbine at a run-of-river plant near Stellenbosch, South Africa, across 40 load rejection events ranging from 10% to 100% of rated output. The digital governor reduced peak frequency deviation by 43.7% on average, shortened the settling time from 14.2 s to 7.8 s, and cut the maximum transient overspeed from 117.4% to 108.3% of synchronous speed. At full-load rejection, the digital controller held the frequency within ±1.78 Hz of nominal, compared with ±3.21 Hz for the analog system. Results indicate that retrofitting a digital PID governor to existing small hydro units offers a cost-effective route to improved frequency stability during load disturbances, with a payback period of 2.3-3.1 years through reduced wear on mechanical components and avoided penalty charges for out-of-band frequency excursions.
- 1 July 2026
- Published by AkiNik Publications in International Journal of Advances in Electrical Engineering
- Vol. 7 (2) , 23-27
Open AccessComparative performance of digital and analog governor controllers for frequency stabilization during load rejection in small-scale run-of-river hydroelectric generators
While large hydroelectric stations have long relied on digital governor systems for turbine speed control, small-scale run-of-river plants below 5 MW overwhelmingly retain analog electronic or mechanical-hydraulic governors and the performance gap between these legacy controllers and modern digital alternatives during load rejection transients has not been quantified through side-by-side field testing. This research compared a digital PID governor and an analog electronic governor on the same 1.8 MW Francis turbine at a run-of-river plant near Stellenbosch, South Africa, across 40 load rejection events ranging from 10% to 100% of rated output. The digital governor reduced peak frequency deviation by 43.7% on average, shortened the settling time from 14.2 s to 7.8 s, and cut the maximum transient overspeed from 117.4% to 108.3% of synchronous speed. At full-load rejection, the digital controller held the frequency within ±1.78 Hz of nominal, compared with ±3.21 Hz for the analog system. Results indicate that retrofitting a digital PID governor to existing small hydro units offers a cost-effective route to improved frequency stability during load disturbances, with a payback period of 2.3-3.1 years through reduced wear on mechanical components and avoided penalty charges for out-of-band frequency excursions.