Continuous Water Infusion Enhances Atmospheric Pressure Chemical Ionization of Methyl Chloroformate Derivatives in Gas Chromatography Coupled to Time-of-Flight Mass Spectrometry-Based Metabolomics
Authors:
- 23 August 2014
- journal article
- research article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 86 (18) , 9186-9195
Abstract
The effects of continuous water infusion on efficiency and repeatability of atmospheric pressure chemical ionization of both methyl chloroformate (MCF) and methoxime-trimethylsilyl (MO-TMS) derivatives of metabolites were evaluated using gas chromatography–time-of-flight mass spectrometry. Water infusion at a flow-rate of 0.4 mL/h yielded not only an average 16.6-fold increase in intensity of the quasimolecular ion for 20 MCF-derivatized metabolite standards through suppression of in-source fragmentation but also the most repeatable peak area integrals. The impact of water infusion was the greatest for dicarboxylic acids and the least for (hetero-) aromatic compounds. Water infusion also improved the ability to detect reliably fold changes as small as 1.33-fold for the same 20 MCF-derivatized metabolite standards spiked into a human serum extract. On the other hand, MO-TMS derivatives were not significantly affected by water infusion, neither in their fragmentation patterns nor with regard to the detection of differentially regulated compounds. As a proof of principle, we applied MCF derivatization and GC-APCI-TOFMS to the detection of changes in abundance of metabolites in pancreatic cancer cells upon treatment with 17-DMAG. Water infusion increased not only the number of metabolites identified via their quasimolecular ion but also the reproducibility of peak areas, thereby almost doubling the number of significantly regulated metabolites (false discovery rate < 0.05) to a total of 23.Keywords
Funding Information
- Deutsche Forschungsgemeinschaft (KFO 262/DE 835/2-1)
This publication has 33 references indexed in Scilit:
- Annotating unknown components from GC/EI-MS-based metabolite profiling experiments using GC/APCI(+)-QTOFMSMetabolomics, 2013
- Advantages of Atmospheric Pressure Chemical Ionization in Gas Chromatography Tandem Mass Spectrometry: Pyrethroid Insecticides as a Case StudyAnalytical Chemistry, 2012
- Performance Evaluation of Gas Chromatography–Atmospheric Pressure Chemical Ionization–Time-of-Flight Mass Spectrometry for Metabolic Fingerprinting and ProfilingAnalytical Chemistry, 2011
- ApplyingIn-SilicoRetention Index and Mass Spectra Matching for Identification of Unknown Metabolites in Accurate Mass GC-TOF Mass SpectrometryAnalytical Chemistry, 2011
- Gas chromatography–atmospheric pressure chemical ionization-time of flight mass spectrometry for profiling of phenolic compounds in extra virgin olive oilJournal of Chromatography A, 2011
- Determination of elemental compositions by gas chromatography/time‐of‐flight mass spectrometry using chemical and electron ionizationRapid Communications in Mass Spectrometry, 2010
- Gas Chromatography/Atmospheric Pressure Chemical Ionization-Time of Flight Mass Spectrometry: Analytical Validation and Applicability to Metabolic ProfilingAnalytical Chemistry, 2009
- Development of a multipurpose ion source for LC-MS and GC-API MSAnalytical and Bioanalytical Chemistry, 2008
- A combination atmospheric pressure LC/MS:GC/MS ion source: Advantages of dual AP-LC/MS:GC/MS instrumentationJournal of the American Society for Mass Spectrometry, 2005
- New picogram detection system based on a mass spectrometer with an external ionization source at atmospheric pressureAnalytical Chemistry, 1973