Evaluation of a Compton Camera System for Whole-Body Imaging of Ac-225: A Simulation Study
- 1 November 2026
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Radiation and Plasma Medical Sciences
- Vol. 10 (8) , 1289-1308
Abstract
In this study, we introduce a Compton camera system design for whole-body imaging of Actinium-225 (225Ac), one of the trending radionuclides for targeted alpha therapy (TAT). The system enables multi-energy gamma photon detection with higher efficiency compared to mechanically collimated SPECT. This design consists of two detectors made of Cadmium zinc telluride (CZT), providing a field of view (FOV) adequate for whole-body imaging, while achieving high sensitivity and clinically usable imaging resolution within a reasonable scanning time. This work focuses on the system design and evaluation using the Monte Carlo simulation toolkit GATE. The imaging performance is evaluated at two energy peaks (218 keV, 440 keV) by applying the energy windows of 211-225 keV and 430-450 keV, representing the major detectable gamma energies generated from 225Ac. We explore the possibility of using the Compton camera system for treatment response monitoring in TAT. The full decay chain of 225Ac is simulated. Results demonstrate an image resolution of 1.0 cm using a NEMA IQ phantom with 5.7 MBq of 225Ac simulated in a cold background. An image resolution of 1.3 cm can be achieved with a hot-to-background ratio of 30:1, and a resolution of 3.7 cm can be achieved with an activity ratio of 12:1. The best achievable sensitivity at a 10 cm distance from the detector is 0.5% at 218 keV and 0.45% at 440 keV as calculated using a pure gamma source in the simulation. The proposed system may serve as an alternative imaging tool for TAT scanning in clinical settings.Keywords
Funding Information
- General Electric
- National Cancer Institute (K08CA259626)
- NIH
This publication has 55 references indexed in Scilit:
- Simulation studies of a full‐ring, CZT SPECT system for whole‐body imaging of 99mTc and 177LuMedical Physics, 2023
- Compton imaging for medical applicationsRadiological Physics and Technology, 2022
- Dose escalation study of targeted alpha therapy with [225Ac]Ac-DOTA-substance P in recurrence glioblastoma – safety and efficacyEuropean Journal of Nuclear Medicine and Molecular Imaging, 2021
- Post-therapy imaging of 225Ac-DOTATATE treatment in a patient with recurrent neuroendocrine tumorEuropean Journal of Nuclear Medicine and Molecular Imaging, 2020
- SPECT Imaging: Basics and New Trends2019
- Quantitative Imaging of Alpha-Emitting Therapeutic RadiopharmaceuticalsNuclear Medicine and Molecular Imaging, 2019
- Analytic simulator and image generator of multiple-scattering Compton camera for prompt gamma ray imagingBiomedical Engineering Letters, 2018
- Quantitative SPECT/CT Imaging of 177Lu with In Vivo Validation in Patients Undergoing Peptide Receptor Radionuclide TherapyMolecular Imaging and Biology, 2014
- Half-lives of 221Fr, 217At, 213Bi, 213Po and 209Pb from the 225Ac decay seriesApplied Radiation and Isotopes, 2013
- Growth of Cd0.9Zn0.1Te Bulk Crystals2011