HSHamid Sabet

Hamid Sabet

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Hamid Sabet has a total of 85 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Evaluation of a Compton Camera System for Whole-Body Imaging of Ac-225: A Simulation Study

    by Yuemeng Feng, Arkadiusz Sitek, Shadi Abdar Esfahani, Hamid Sabet

    In this study, we introduce a Compton camera system design for whole-body imaging of Actinium-225 (225Ac), one of the trending radionuclides for targeted alpha therapy (TAT). The system enables multi-energy gamma photon detection with higher efficiency compared to mechanically collimated SPECT. This design consists of two detectors made of Cadmium zinc telluride (CZT), providing a field of view (FOV) adequate for whole-body imaging, while achieving high sensitivity and clinically usable imaging resolution within a reasonable scanning time. This work focuses on the system design and evaluation using the Monte Carlo simulation toolkit GATE. The imaging performance is evaluated at two energy peaks (218 keV, 440 keV) by applying the energy windows of 211-225 keV and 430-450 keV, representing the major detectable gamma energies generated from 225Ac. We explore the possibility of using the Compton camera system for treatment response monitoring in TAT. The full decay chain of 225Ac is simulated. Results demonstrate an image resolution of 1.0 cm using a NEMA IQ phantom with 5.7 MBq of 225Ac simulated in a cold background. An image resolution of 1.3 cm can be achieved with a hot-to-background ratio of 30:1, and a resolution of 3.7 cm can be achieved with an activity ratio of 12:1. The best achievable sensitivity at a 10 cm distance from the detector is 0.5% at 218 keV and 0.45% at 440 keV as calculated using a pure gamma source in the simulation. The proposed system may serve as an alternative imaging tool for TAT scanning in clinical settings.

  • Open Access

    Patient-specific modeling enables specific activity optimization to maximize tumor absorbed dose in transarterial radioembolization

    by Carlos Huesa-Berral, Robert J. Dawson, Hamid Sabet, Macarena Rodríguez-Fraile, Raneem Atta, Harald Paganetti, Wesley E. Bolch, Eric Wehrenberg-Klee, Alejandro Bertolet

    Transarterial radioembolization (TARE) is evolving from palliative to curative in the management of hepatocellular carcinoma (HCC). Alongside, there is a g

  • Maximum-Likelihood-Based Position Decoding of Laser-Processed Converging-Pixel CsI:Tl Detectors for High-Resolution SPECT

    by Xi Zhang, Arkadiusz Sitek, Lisa Blackberg, Matthew A. Kupinski, Lars R. Furenlid, Hamid Sabet

    This study demonstrates the feasibility of a novel fabrication technique for high spatial resolution CsI: Tl scintillation detectors tailored for single photon emission computed tomography (SPECT) systems. Building upon our previously developed laser induced optical barrier (LIOB) method, which achieved high spatial resolution, excellent sensitivity, and 100% fabrication yield in CsI: Tl detectors, we extend this approach to a converging-pixel architecture. A CsI: Tl crystal array with converging pixels was designed and fabricated, featuring entrance-face pixels of 1.6x1.6 mm2 and photodetector side pixels of 2x2 mm2. To localize gamma-ray interactions, both the center of gravity (CoG) algorithm and a maximum-likelihood (ML) based decoding method were implemented. A custom built four axis motion platform was developed to deliver a finely collimated pencil beam at precisely controlled positions and angles across the array, enabling generation of a comprehensive dataset for prior knowledge and validation. The results demonstrate an energy resolution of 11.79+/-0.53% (collimated experiment) and a position localization accuracy of 1.00+/-0.42 mm (nearest neighbor interpolation), confirming that the proposed converging-pixel architecture, combined with statistical decoding algorithms, provides a promising path toward the development of high-performance SPECT detectors.

  • Open Access

    A novel perspective on denoising using quantum localization with application to medical imaging

    by Amirreza Hashemi, Sayantan Dutta, Bertrand Georgeot, Denis Kouamé, Hamid Sabet

    Background noise in many fields, such as medical imaging, poses significant challenges for accurate diagnosis, prompting the development of denoising algorithms. Traditional methodologies, however, often struggle to address the complexities of noisy environments in high dimensional imaging systems. This paper introduces a novel quantum-inspired approach for image denoising, drawing upon principles of quantum and condensed matter physics. Our approach views medical images as amorphous structures akin to those found in condensed matter physics, and we propose an algorithm that incorporates the concept of mode resolved localization directly into the denoising process. Notably, unlike previous studies that considered localization as a hindrance, our approach considers quantum localization as a fundamental component of image reconstruction, which is used to differentiate between noisy and non-noisy modes based on diffusivity and localization measurements. This perspective eliminates the need for hyperparameter tuning, making the proposed method a standalone algorithm that can be implemented with minimal manual intervention and can perform automatic filtering of noise regardless of noise level. Through numerical validation, we showcase the effectiveness of our approach in addressing noise-related challenges in imaging, and especially medical imaging, underscoring its relevance for possible quantum computing applications.


  • Analytical methods for system matrix calculation and spatial resolution evaluation of DC-SPECT system

    by Yuemeng Feng, Matthew A Kupinski, Mark P Ottensmeyer, William Worstell, Ahmed Tawakol, Lars R Furenlid, Hamid Sabet

    Objective. To develop and evaluate an analytical method for calculating the system matrix of a dynamic cardiac single photon emission computed tomography (DC-SPECT) system, eliminating the need for computationally intensive Monte Carlo (MC) simulations. Approach. An analytical model was proposed for system matrix generation, incorporating solid angle calculations adapted for square-shaped pinhole collimators. The resulting sensitivity maps were validated against MC simulation results. Image reconstructions using the proposed analytical model were compared to those using an MC-simulated system matrix. Additionally, the overall system performance, including sensitivity and spatial resolution, was assessed using MC simulations. Main results. The analytical sensitivity map showed good agreement with MC-based results. Reconstructed images using the analytical model preserved key features but showed reduced performance compared to MC-based reconstructions. MC simulations of DC-SPECT demonstrated a spatial resolution of 5.5 mm for hot regions and 6.0 mm for cold regions, with an overall system sensitivity of 0.07% over a 15 cm diameter spherical field of view. Significance. The proposed analytical method offers a fast and practical alternative to MC-based system matrix generation, enabling efficient system design and prototyping. While its use in clinical image reconstruction requires further evaluation, the model provides a promising tool for accelerating the development of next-generation DC-SPECT systems.


  • Flexible and Generic Framework for Complex Nuclear Medicine Scanners Using FreeCAD/GDML Workbench

    by Anh Le, Amirreza Hashemi, Mark Ottensmeyer, Hamid Sabet

    Computer-Aided Design and Applications is an international journal on the applications of CAD and CAM. It publishes papers in the general domain of CAD plus in emerging fields like bio-CAD, nano-CAD, soft-CAD, garment-CAD, PLM, PDM, CAD data mining, CAD and the internet, CAD education, genetic algorithms and CAD engines. The journal is aimed at all developers and users of CAD technology to ptovide CAD solutions for various stages of design and manufacturing. The journal publishes all about Computer-Aided Design and Computer-Aided technologies.


  • Open Access

    Large-Diameter Bulk Crystal Growth and Scintillation Characterization of Thallium-Based Ternary Halide Crystals for Detection and Imaging

    by Rastgo Hawrami, Elsa Ariesanti, Hamid Sabet

    Scintillators are important for a wide range of applications in detection and imaging. In this paper, the growth and performance results of advanced large-diameter thallium-based ternary halide crystals are presented. Intrinsic crystals of TlMgCl3, TlCaCl3, and other small-diameter TlCaBr3, and TlCa(Cl,Br)3, as well as europium-doped TlCa2Br5, TlCa(Cl,Br)3, and TlSr2I5 are melt-grown by the Bridgman method. These compounds have a high effective atomic number (Zeff) and physical densities due to thallium. The best crystal quality and energy resolution (FWHM) at 662 keV are observed for TlMgCl3, TlCaCl3, and TlSr2I5:Eu at 3.8%, 4.6%, and 3.5%, respectively. The primary decay constants for these compounds are in the range of 0.45 to 0.63 μs. These ternary Tl-halide compounds have proportional or linear response (±0.05%) to γ-rays above 40 keV.


  • Open Access

    Achievable Resolution for Scalable Waveform Digitizing PET Readout and Comparison with Ideal TDC-based Readout with an Application of DNN to Optimal Estimation Including DOI.

    by L. Macchiarulo, C. Chock, I. Mostafanezhad, H. Sabet

    Time Of Flight PET (TOF-PET) is a transformative technology for PET systems, but reaping its fullest potential requires achieving very high spatial and timing resolution, and overcoming dependency on signal variability at the level of the individual pixels. In this study, we try to quantify the advantage of using custom waveform sampling devices versus TDC methodology using realistic estimates of noise and other non-idealities. With the use of DNN methodology we show achievable gain for current and future acquisition systems, and also demonstrate the feasibility of DOI estimation from single side readout. We conclude by arguing for the scalability of such a system based on our experience with compact waveform digitizer design.

  • Open Access

    Limited-angle TOF-PET for intraoperative surgical applications: Simulation Study

    by Salar Sajedi, Yuemeng Feng, Hamid Sabet

    In this work, we present modeling and imaging performance of a dual panel limited-angle TOF-PET system for intraoperative surgical applications using GATE monte carlo toolkit. Several detector parameters such as detector pixel dimensions, timing resolution and depth of interaction resolution along with tumor uptake ratio and phantom dimension are varied. Ultimately TOF-PET detector properties to achieve a specific imaging task are presented. To assess image resolution, we employed Simple Back Projection (SBP) reconstruction due to its fast speed compared to list-mode Maximum Likelihood Expectation Maximization (MLEM). We evaluated the quality of the reconstructed images using metrics contrast-to-noise ratio (CNR), contrast recovery coefficient (CRC), and signal-to-noise ratio (SNR). The purpose is to show effects of different detector parameters on the resolution of reconstructed images.


  • Open Access

    Resolution recovery on list mode MLEM reconstruction for dynamic cardiac SPECT system

    by Yuemeng Feng, William Worstell, Matthew Kupinski, Lars R Furenlid, Hamid Sabet

    The Dynamic Cardiac SPECT (DC-SPECT) system is being developed at the Massachusetts General Hospital, featuring a static cardio focus asymmetrical geometry enabling simultaneous high-resolution and high-sensitivity imaging. Among 14 design iterations of the DC-SPECT with varying number of detector heads, system sensitivity and resolution, the current version under development features 10 mm FWHM geometrical resolution (without resolution recovery) and 0.07% sensitivity at the center of the FOV, this is 1.5× resolution gain and 7× sensitivity gain compared to a conventional dual head gamma camera (0.01% sensitivity and 15-mm resolution). This work presents improvement in imaging resolution by implementing a spatially variant point spread function (SV-PSF) with list mode MLEM reconstruction. A resolution recovery method by PSF deconvolution is validated on list mode MLEM reconstruction for the DC-SPECT. A spatial invariant PSF is included as an additional test to show the influence of the PSF modelling accuracy on reconstructed image quality. We compare the MLEM reconstruction with and without PSF deconvolution; an analytic model is used for the calculation of system response, and the results are compared to the reconstruction with system modelling using Monte Carlo (MC) based methods. Results show that with PSF modelling applied, the quality of the reconstructed image is improved, and the DC-SPECT system can achieve a 4.5 mm central spatial resolution with average 795 counts/Mbq. Both the SV-PSF and the spatial-invariant PSF improve the image quality, and the reconstruction with SV-PSF generates line profiles closer to the ground truth. The results show substantial improvement over the GE Discovery 570c performance (7 mm spatial resolution with an average 460 counts/MBq, 5.8 mm resolution at the FOV center). The impact of PSF deconvolution is significant, improvement of the reconstructed image quality is evident in comparison to MC simulated system matrix with the same sampling size in the simulation.