Resolution recovery on list mode MLEM reconstruction for dynamic cardiac SPECT system
Open Access
- 5 December 2023
- journal article
- research article
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 10 (1) , 015009
Abstract
The Dynamic Cardiac SPECT (DC-SPECT) system is being developed at the Massachusetts General Hospital, featuring a static cardio focus asymmetrical geometry enabling simultaneous high-resolution and high-sensitivity imaging. Among 14 design iterations of the DC-SPECT with varying number of detector heads, system sensitivity and resolution, the current version under development features 10 mm FWHM geometrical resolution (without resolution recovery) and 0.07% sensitivity at the center of the FOV, this is 1.5× resolution gain and 7× sensitivity gain compared to a conventional dual head gamma camera (0.01% sensitivity and 15-mm resolution). This work presents improvement in imaging resolution by implementing a spatially variant point spread function (SV-PSF) with list mode MLEM reconstruction. A resolution recovery method by PSF deconvolution is validated on list mode MLEM reconstruction for the DC-SPECT. A spatial invariant PSF is included as an additional test to show the influence of the PSF modelling accuracy on reconstructed image quality. We compare the MLEM reconstruction with and without PSF deconvolution; an analytic model is used for the calculation of system response, and the results are compared to the reconstruction with system modelling using Monte Carlo (MC) based methods. Results show that with PSF modelling applied, the quality of the reconstructed image is improved, and the DC-SPECT system can achieve a 4.5 mm central spatial resolution with average 795 counts/Mbq. Both the SV-PSF and the spatial-invariant PSF improve the image quality, and the reconstruction with SV-PSF generates line profiles closer to the ground truth. The results show substantial improvement over the GE Discovery 570c performance (7 mm spatial resolution with an average 460 counts/MBq, 5.8 mm resolution at the FOV center). The impact of PSF deconvolution is significant, improvement of the reconstructed image quality is evident in comparison to MC simulated system matrix with the same sampling size in the simulation.Keywords
All Related Versions
Funding Information
- NIH (R01HL145160)
This publication has 19 references indexed in Scilit:
- Light Spread Manipulation in Scintillators Using Laser Induced Optical BarriersIEEE Transactions on Nuclear Science, 2018
- PSF reconstruction for Compton-based prompt gamma imagingPhysics in Medicine & Biology, 2018
- Novel laser-processed CsI:Tl detector for SPECTMedical Physics, 2016
- Improved image quality in pinhole SPECT by accurate modeling of the point spread function in low magnification systemsMedical Physics, 2015
- Comparative analysis of iterative reconstruction algorithms with resolution recovery for cardiac SPECT studies. A multi-center phantom studyJournal of Nuclear Cardiology, 2014
- Practical considerations for image-based PSF and blobs reconstruction in PETPhysics in Medicine & Biology, 2013
- Correction for Collimator-Detector Response in SPECT Using Point Spread Function TemplateIEEE Transactions on Medical Imaging, 2012
- A System Calibration and Fast Iterative Reconstruction Method for Next-Generation SPECT ImagersIEEE Transactions on Nuclear Science, 2012
- Analytic derivation of pinhole collimation sensitivity for a general source model using spherical harmonicsPhysics in Medicine & Biology, 2010
- EM algorithm system modeling by image-space techniques for PET reconstructionIEEE Transactions on Nuclear Science, 2003