Maria A. Koponen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Maria A. Koponen has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
- Risto Juhani Ilmoniemi
Aalto University
5 shared publications - Victor Hugo Souza
Department of Neuroscience and Biomedical Engineering, Aalto University, Espoo, Finland
5 shared publications - Heikki Sinisalo
Department of Neuroscience and Biomedical Engineering, Aalto University School of Science, Espoo, Finland
3 shared publications - Jaakko Paasonen
A. I. Virtanen Institute for Molecular Sciences, University of Eastern Finland , Neulaniementie 2, FI-70211, Kuopio
3 shared publications - Juuso T. Korhonen
Department of Neuroscience and Biomedical Engineering, Aalto University School of Science, Espoo, Finland
3 shared publications - Olli Gröhn
A. I. Virtanen Institute for Molecular Sciences, University of Eastern Finland, Kuopio, Finland
3 shared publications
Latest Publications
- Open Access
- 28 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Electromagnetics, RF and Microwaves in Medicine and Biology
- Vol. 10 (1) , 170-178
Design of Mechanical Durable TMS Coils for Safe Operation in High-Field MRI Environments
Objective: Interleaving transcranial magnetic stimulation with magnetic resonance imaging (TMS–MRI) is a promising tool for neuroscience. However, its development is limited by the strong interactions between the TMS current pulse and the high magnetic field present within the MRI environment. The objective of this study is to develop methodologies for designing TMS coils that can operate safely inside MRI scanners. Methods: By using an inverse boundary element method design framework, we study the effects of controlling different norms of the Lorentz force in the design process to produce more durable TMS coils. We apply this method to design rodent–specific TMS coils capable of withstanding the high static magnetic fields present in small animal MRI scanners. The performance of the proposed TMS coils is validated under realistic simulations using practical coil plate materials and pulses in the COMSOL Multiphysics software. Results: The numerical simulations indicate that minimising the maximum magnitude ($l^{\infty}$ norm) of the Lorentz force distribution produces TMS coils with improved mechanical behaviour when operating within an MRI environment. Significance: The proposed design strategy offers an effective solution for producing TMS coils with enhanced mechanical durability. This improvement may be particularly valuable to address the current challenges faced in interleaved TMS–MRI applications.
- 28 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Electromagnetics, RF and Microwaves in Medicine and Biology
- Vol. 10 (1) , 170-178
Open AccessDesign of Mechanical Durable TMS Coils for Safe Operation in High-Field MRI Environments
Objective: Interleaving transcranial magnetic stimulation with magnetic resonance imaging (TMS–MRI) is a promising tool for neuroscience. However, its development is limited by the strong interactions between the TMS current pulse and the high magnetic field present within the MRI environment. The objective of this study is to develop methodologies for designing TMS coils that can operate safely inside MRI scanners. Methods: By using an inverse boundary element method design framework, we study the effects of controlling different norms of the Lorentz force in the design process to produce more durable TMS coils. We apply this method to design rodent–specific TMS coils capable of withstanding the high static magnetic fields present in small animal MRI scanners. The performance of the proposed TMS coils is validated under realistic simulations using practical coil plate materials and pulses in the COMSOL Multiphysics software. Results: The numerical simulations indicate that minimising the maximum magnitude ($l^{\infty}$ norm) of the Lorentz force distribution produces TMS coils with improved mechanical behaviour when operating within an MRI environment. Significance: The proposed design strategy offers an effective solution for producing TMS coils with enhanced mechanical durability. This improvement may be particularly valuable to address the current challenges faced in interleaved TMS–MRI applications.
- 1 December 2025
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 158 (6) , 4963-4970
Attenuation of acoustic energy in transcranial magnetic stimulation coils by viscous media
Transcranial magnetic stimulation (TMS) is an established treatment for neurological and mental disorders such as depression, chronic pain, and anxiety. These ailments can be treated by exciting localized regions in the brain with magnetic fields produced with an electromagnetic coil. When pulsed, kiloampere-level currents travel down the coil in a time scale of tens to hundreds of microseconds, generating a loud click-like noise. This sound can interfere with the intended TMS excitation in the brain and, without careful protection, cause permanent hearing damage to both the patient and the operator, as well as shorten the lifespan of the TMS coil. This work explores the potential of using highly viscous media, such as honey, to suppress wire vibrations in TMS coils, thereby reducing the resulting acoustic emissions. We demonstrate that using a viscous medium surrounding the TMS coil reduces sound intensity by up to 19 dB. Furthermore, lowering the temperature of the viscous medium increases the viscosity and dampens coil vibration. We foresee that future use of viscous media in TMS coils may extend their lifetime and improve operator and subject safety.
- 1 December 2025
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 158 (6) , 4963-4970
Attenuation of acoustic energy in transcranial magnetic stimulation coils by viscous media
Transcranial magnetic stimulation (TMS) is an established treatment for neurological and mental disorders such as depression, chronic pain, and anxiety. These ailments can be treated by exciting localized regions in the brain with magnetic fields produced with an electromagnetic coil. When pulsed, kiloampere-level currents travel down the coil in a time scale of tens to hundreds of microseconds, generating a loud click-like noise. This sound can interfere with the intended TMS excitation in the brain and, without careful protection, cause permanent hearing damage to both the patient and the operator, as well as shorten the lifespan of the TMS coil. This work explores the potential of using highly viscous media, such as honey, to suppress wire vibrations in TMS coils, thereby reducing the resulting acoustic emissions. We demonstrate that using a viscous medium surrounding the TMS coil reduces sound intensity by up to 19 dB. Furthermore, lowering the temperature of the viscous medium increases the viscosity and dampens coil vibration. We foresee that future use of viscous media in TMS coils may extend their lifetime and improve operator and subject safety.
- Open Access
- 2 May 2025
- Published by MIT Press in Imaging Neuroscience
- Vol. 3
Multi-coil TMS for preclinical applications in ultra-high-field MRI
Monitoring cortical responses to neuromodulation on preclinical models can elucidate fundamental mechanisms of brain function. Concurrent brain stimulation and imaging is challenging, usually compromising spatiotemporal resolution, accuracy, and versatility. Here, we report on a non-invasive brain stimulation system with electronic control of neuromodulation parameters in a 9.4-T magnetic resonance imaging (MRI) environment. In the imaging scanner, multi-coil transcranial magnetic stimulation (mTMS) is delivered with a 2-coil array, and the MRI signal is measured with a radiofrequency coil. The mTMS can change the stimulus orientation with 1° resolution in a millisecond. Without physically rotating the coils, we evoked orientation-specific muscle responses after cortical stimulation on an anesthetized rat. The mTMS system was successfully implemented and tested with the small-animal MRI, showing minimal interference with B0 and B1+ fields and uncompromised image quality. A delay of 40 ms between the stimulation pulse and fMRI acquisition—similar or even shorter than those previously described in humans—led to artifact-free images. Concurrent electronically targeted brain stimulation and neuroimaging provides a valuable tool for exploring whole-brain network functions, endorsing more efficient treatment protocols.
- 2 May 2025
- Published by MIT Press in Imaging Neuroscience
- Vol. 3
Open AccessMulti-coil TMS for preclinical applications in ultra-high-field MRI
Monitoring cortical responses to neuromodulation on preclinical models can elucidate fundamental mechanisms of brain function. Concurrent brain stimulation and imaging is challenging, usually compromising spatiotemporal resolution, accuracy, and versatility. Here, we report on a non-invasive brain stimulation system with electronic control of neuromodulation parameters in a 9.4-T magnetic resonance imaging (MRI) environment. In the imaging scanner, multi-coil transcranial magnetic stimulation (mTMS) is delivered with a 2-coil array, and the MRI signal is measured with a radiofrequency coil. The mTMS can change the stimulus orientation with 1° resolution in a millisecond. Without physically rotating the coils, we evoked orientation-specific muscle responses after cortical stimulation on an anesthetized rat. The mTMS system was successfully implemented and tested with the small-animal MRI, showing minimal interference with B0 and B1+ fields and uncompromised image quality. A delay of 40 ms between the stimulation pulse and fMRI acquisition—similar or even shorter than those previously described in humans—led to artifact-free images. Concurrent electronically targeted brain stimulation and neuroimaging provides a valuable tool for exploring whole-brain network functions, endorsing more efficient treatment protocols.
- Open Access
- 14 August 2024
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 69 (17) , 175001
Modeling the stress and forces on multi-channel TMS coil arrays in high-field MRI scanners
Transcranial magnetic stimulation (TMS) is a non-invasive method for stimulating the cortex. Concurrent functional magnetic resonance imaging can show changes in TMS-induced activity in the whole brain, with the potential to inform brain function research and to guide the development of TMS therapy. However, the interaction of the strong current pulses in the TMS coil in the static main magnetic field of the MRI produces high Lorentz forces, which may damage the coil enclosure and compromise the patient’s safety. We studied the time-dependent mechanical behavior and durability of two multi-locus TMS (mTMS) coil arrays inside a high-field MRI bore with finite element modeling. In addition, coil arrays were built and tested based on the simulation results. We found that the current pulses produce shock waves and time-dependent stress distribution in the coil plates. The intensity and location of the maximum stress depend on the current waveform, the coil combination, and the transducer orientation relative to the MRI magnetic field. We found that 30% glass-fiber-filled polyamide is the most durable material out of the six options studied. In addition, novel insights for more durable TMS coil designs were obtained. Our study contributes to a comprehensive understanding of the underlying mechanisms responsible for the structural failure of mTMS coil arrays during stimulation within high static magnetic fields. This knowledge is essential for developing mechanically stable and safe mTMS-MRI transducers.
- 14 August 2024
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 69 (17) , 175001
Open AccessModeling the stress and forces on multi-channel TMS coil arrays in high-field MRI scanners
Transcranial magnetic stimulation (TMS) is a non-invasive method for stimulating the cortex. Concurrent functional magnetic resonance imaging can show changes in TMS-induced activity in the whole brain, with the potential to inform brain function research and to guide the development of TMS therapy. However, the interaction of the strong current pulses in the TMS coil in the static main magnetic field of the MRI produces high Lorentz forces, which may damage the coil enclosure and compromise the patient’s safety. We studied the time-dependent mechanical behavior and durability of two multi-locus TMS (mTMS) coil arrays inside a high-field MRI bore with finite element modeling. In addition, coil arrays were built and tested based on the simulation results. We found that the current pulses produce shock waves and time-dependent stress distribution in the coil plates. The intensity and location of the maximum stress depend on the current waveform, the coil combination, and the transducer orientation relative to the MRI magnetic field. We found that 30% glass-fiber-filled polyamide is the most durable material out of the six options studied. In addition, novel insights for more durable TMS coil designs were obtained. Our study contributes to a comprehensive understanding of the underlying mechanisms responsible for the structural failure of mTMS coil arrays during stimulation within high static magnetic fields. This knowledge is essential for developing mechanically stable and safe mTMS-MRI transducers.
- Open Access
A multi-channel TMS system enabling accurate stimulus orientation control during concurrent ultra-high-field MRI for preclinical applications
Monitoring cortical responses to neuromodulation protocols on preclinical models can elucidate fundamental mechanisms of brain function. Concurrent brain stimulation and imaging is challenging, usually compromising spatiotemporal resolution, accuracy, and versatility. Here we report a non-invasive brain stimulation system with electronic control of neuromodulation parameters in a 9.4-T magnetic resonance imaging (MRI) environment. In the imaging scanner, transcranial magnetic stimulation is delivered with a set of two coils and the MRI signals are recorded with a radiofrequency coil. The coil set provides millisecond-scale electronic control of the stimulus orientation with 1° resolution. Without physically rotating the coils, we evoked orientation-specific muscle responses after cortical stimulation on an anesthetized rat. We show that the stimulation pulses do not affect the anatomical imaging quality, and imaging signals are disrupted only if recorded before 10 ms after pulse delivery. Concurrent electronically targeted brain stimulation and neuroimaging sets the stage for the causal investigation of whole-brain network functions, endorsing more efficient treatment protocols.
Open AccessA multi-channel TMS system enabling accurate stimulus orientation control during concurrent ultra-high-field MRI for preclinical applications
Monitoring cortical responses to neuromodulation protocols on preclinical models can elucidate fundamental mechanisms of brain function. Concurrent brain stimulation and imaging is challenging, usually compromising spatiotemporal resolution, accuracy, and versatility. Here we report a non-invasive brain stimulation system with electronic control of neuromodulation parameters in a 9.4-T magnetic resonance imaging (MRI) environment. In the imaging scanner, transcranial magnetic stimulation is delivered with a set of two coils and the MRI signals are recorded with a radiofrequency coil. The coil set provides millisecond-scale electronic control of the stimulus orientation with 1° resolution. Without physically rotating the coils, we evoked orientation-specific muscle responses after cortical stimulation on an anesthetized rat. We show that the stimulation pulses do not affect the anatomical imaging quality, and imaging signals are disrupted only if recorded before 10 ms after pulse delivery. Concurrent electronically targeted brain stimulation and neuroimaging sets the stage for the causal investigation of whole-brain network functions, endorsing more efficient treatment protocols.