JSJohannes Spaeth

Johannes Spaeth

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Johannes Spaeth has a total of 42 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Anesthesia workstation performance in pediatric ventilation – Part 1: Precision of ventilation.

    by Johannes Spaeth, Malte Trost, Bernd Flamm, Christin M.Sc. Wenzel, Stefan Schumann

    Background.: Mechanical ventilation of children sets the highest demands on the performance of anesthesia workstations. Different ventilator technologies are available, each representing unique pneumatic characteristics. We hypothesized that precision of delivered ventilation parameters depends on the ventilator type. Methods.: Six modern anesthesia workstations (GE HealthCare Carestation 650; Mindray Bio-Medical Electronics Co. Ltd. Wato EX-65 Pro and A9; Dräger Medical Atlan A350 and Perseus A500; Getinge Flow-c) were tested in physical models simulating the respiratory systems of a preterm baby, a neonate, an infant and a toddler. Volume-controlled and pressure-controlled ventilation were investigated with and without airway leakage. Delivered tidal volume, peak inspiratory pressure, positive end-expiratory pressure and inspiratory to expiratory ratio were compared to the set values. Data are presented descriptively, a difference ≥ 10 % between delivered and the set values was considered clinically relevant. Results.: Deviations of the delivered volume from the set tidal volume during volume-controlled ventilation ranged between -19.5 ± 0.6 % and +35.1 ± 3.0 % in the preterm baby model, but decreased with increasing tidal volume. Positive end-expiratory pressure and peak inspiratory pressure during pressure-controlled ventilation did not differ relevantly from the set values in any device or lung model. Expiratory ratios varied widely in most devices leading to relevant differences in tidal volume during pressure-controlled ventilation. With leakage, tidal volume was on average 7 % lower during volume-controlled ventilation but 2 % lower during pressure-controlled ventilation. Conclusions.: Precision of ventilation with modern anesthesia workstations varies depending on the ventilator type, ventilation mode and the set parameters. Pressure-controlled ventilation is advantageous in the six workstations tested considering the good agreement between the applied and the set parameters and leakage compensation. Our results imply precision superiority of pressure-controlled ventilation over volume-controlled ventilation in preterm babies and neonates, independent from the ventilator technology in use.


  • Anesthesia workstation performance in pediatric ventilation – Part 2: Characteristics during pressure support ventilation and oxygen rise times.

    by Johannes Spaeth, Malte Trost, Bernd Flamm, Christin M.Sc. Wenzel, Stefan Schumann

    Background.: Modern anesthesia workstations include various ventilator technologies, but the effects on pediatric ventilation are unclear. We hypothesized that performance during pressure support ventilation and times to increase oxygen concentrations depend on the type of anesthesia workstation. Methods.: Six modern anesthesia workstations (GE HealthCare Carestation 650; Mindray Bio-Medical Electronics Co. Ltd. Wato EX-65 Pro and A9; Dräger Medical Atlan A350 and Perseus A500; Getinge Flow-c) were evaluated in respiratory models of a preterm baby, a neonate, an infant and a toddler. Trigger response rates, trigger delay and time to reach 50 % of peak inspiratory pressure during pressure support ventilation were compared. Furthermore, the times required to increase oxygen concentration from 21 to 90 % during pressure-controlled ventilation at fresh gas flows of 1, 3 and 10 l·min -1 were assessed in a compartment of the lung models with the volume corresponding to the respective model’s functional residual capacity. Results.: Trigger response rates were above 90 %, with few exceptions. Trigger delays ranged between 73 ± 6 ms and 145 ± 0 ms. Times to reach 50 % peak pressure ranged between 161 ± 1 ms and 312 ± 1 ms, with decreasing variability in the larger patient models. Oxygen rise time varied between 94 ± 3 s and 615 ± 60 s at the lowest fresh gas flow and decreased with increasing fresh gas flow to 3 l·min -1 , and less so with further increasing fresh gas flow to 10 l·min -1 . Activation of oxygen flush did not generally increase oxygen concentration but caused relevant airway pressure increases in some devices. Conclusions.: Modern anesthesia workstations show an overall good performance during pressure support ventilation of children. During pressure-controlled ventilation a moderate increase of fresh gas flow accelerated the rise in oxygen concentration, depending on the device. Oxygen flush brings no advantage in this regard but may put the patient at risk of high airway pressure.


  • Open Access

    Comparison of Force Distribution during Laryngoscopy with the C-MAC D-BLADE and Macintosh-Style Blades: A Randomised Controlled Clinical Trial

    by Axel Schmutz, Ingo Breddin, Ramona Draxler, Stefan Schumann, Johannes Spaeth

    Background: The geometry of a laryngoscope’s blade determines the forces acting on the pharyngeal structures to a relevant degree. Knowledge about the force distribution along the blade may prospectively allow for the development of less traumatic blades. Therefore, we examined the forces along the blades experienced during laryngoscopy with the C-MAC D-BLADE and blades of the Macintosh style. We hypothesised that lower peak forces are applied to the patient’s pharyngeal tissue during videolaryngoscopy with a C-MAC D-BLADE compared to videolaryngoscopy with a C-MAC Macintosh-style blade and direct laryngoscopy with a Macintosh-style blade. Beyond that, we assumed that the distribution of forces along the blade differs depending on the respective blade’s geometry. Methods: After ethical approval, videolaryngoscopy with the D-BLADE or the Macintosh blade, or direct laryngoscopy with the Macintosh blade (all KARL STORZ, Tuttlingen, Germany), was performed on 164 randomly assigned patients. Forces were measured at six positions along each blade and compared with regard to mean force, peak force and spatial distribution. Furthermore, the duration of the laryngoscopy was measured. Results: Mean forces (all p < 0.011) and peak forces at each sensor position (all p < 0.019) were the lowest with the D-BLADE, whereas there were no differences between videolaryngoscopy and direct laryngoscopy with the Macintosh blades (all p > 0.128). With the D-BLADE, the forces were highest at the blade’s tip. In contrast, the forces were more evenly distributed along the Macintosh blades. Videolaryngoscopy took the longest with the D-BLADE (p = 0.007). Conclusions: Laryngoscopy with the D-BLADE resulted in significantly lower forces acting on pharyngeal and laryngeal tissue compared to Macintosh-style blades. Interestingly, with the Macintosh blades, we found no advantage for videolaryngoscopy in terms of force application.


  • Open Access

    Comparative usability of manual defibrillators – A human factors study

    by Stefan Schumann, Axel Schmutz, Kim Feger, Johannes Spaeth


  • Open Access

    Understanding pediatric ventilation in the operative setting. Part I: Physical principles of monitoring in the modern anesthesia workstation

    by Johannes Spaeth, Stefan Schumann, Susan Humphreys

    The modern anesthesia workstation provides a wealth of information some of which is of particular interest when it comes to optimizing ventilation settings. This knowledge gains even more importance in the therapy of pediatric patients. In the absence of evidence‐based recommendations on optimal ventilation settings in pediatric patients, the evaluation of individual factors becomes crucial and challenging at the same time. Even when equipped with the latest sensor technology, the user will always have to be in charge of interpreting the provided monitoring variables. The purpose of this review is to outline the clinical impact, technological background, and reliability of the most relevant information measured and calculated by a modern anesthesia workstation. It aims at translating the technical knowledge into a more competent and vigilant application in the clinical setting.


  • Open Access

    Understanding pediatric ventilation in the operative setting. Part II: Setting perioperative ventilation

    by Johannes Spaeth, Stefan Schumann, Susan Humphreys

    Approaches toward lung‐protective ventilation have increasingly been investigated in recent years. Despite evidence being found in adults undergoing surgery, data in younger children are still scarce and controversial. From a physiological perspective, however, the continuously changing characteristics of the respiratory system from birth through adolescence require an approach based on the analysis of each individual patient. The modern anesthesia workstation provides such information, with the technical strengths and weaknesses being discussed in a review preceding the present work (see Part I). The present summary aims to provide ideas on how to translate the information displayed on the anesthesia workstation to patient‐oriented clinical ventilation settings.


  • Open Access

    Transurethrale Resektion der Prostata unter Verwendung einer suprapubischen Absaugvorrichtung

    by Dominik Schöb, Anja Reichelt, Maria Cazana, Martin Schoenthaler, Simon Hein, Daniel Schlager, Arndt Katzenwadel, Johannes Spaeth, Ulrich Wetterauer, Arkadiusz Miernik, et al.

  • Open Access

    Low-pressure monopolar electroresection of the prostate for glands sized > 70 vs. < 70 cc performed with continuous irrigation and suprapubic suction: perioperative and long-term outcome

    by Konrad Wilhelm, Ioana Maria Cazana, Martin Schoenthaler, Arndt Katzenwadel, Johannes Spaeth, Arkadiusz Miernik

    Purpose: To evaluate long-term efficacy and safety of low-pressure transurethral resection of the prostate for prostates < 70 cc (group 1) vs. > 70 cc (group 2). Patients and methods: In this study patients operated with monopolar TURP between 2009 and 2012 were evaluated retrospectively. During surgery a specially designed trocar (18 Fr) was placed suprapubically and connected to a suction pump to maintain stable low-pressure conditions. After sample size calculations, long-term follow-up was completed for 70 invited patients in each group up to 9/2015. Results: Follow-up period was 57 vs. 56 months for group 1 and 2, respectively (p = 0.56). At baseline there was no significant difference in age, IPSS, peak flow, and post void residual (PVR). Mean prostate volume was 47 cc (15–65) vs. 100 cc (70–163). Mean operating time was 55.4 vs. 82.6 min (p = 0.00). Blood transfusion was necessary in 0.0 vs. 2.9% (p = 0.16), and 0.0 vs. 1.4% developed TUR syndrome (p = 0.32). At follow-up mean relative improvement in IPSS was 63 vs. 57% (p = 0.29), QoL 64 vs. 64% (p = 0.93), peak flow 139 vs. 130% (p = 0.85), and PVR 58 vs. 63% (p = 0.80). Long-term complications included recurring adenoma in 1.4 vs. 4.3% (p = 0.31), and stricture in 7.2 vs. 5.8% (p = 0.73). 1 patient in each group reported worsening incontinence symptoms. Conclusions: In terms of safety and efficacy, the aforementioned modality of standardized monopolar TURP using suprapubic suction was non-inferior for prostates > 70 cc compared to the same procedure for prostates < 70 cc. This technique is a potential low-cost alternative for clinics that cannot afford modern laser approaches. Study register number: DRKS00006527.


  • Pressure‐flow characteristics of breathing systems and their components for pediatric and adult patients

    by Christin Wenzel, Stefan Schumann, Johannes Spaeth

    Summary: Background: Breathing circuits connect the ventilator to the patients’ respiratory system. Breathing tubes, connectors, and sensors contribute to artificial airway resistance to a varying extent. We hypothesized that the flow‐dependent resistance is higher in pediatric breathing systems and their components compared to respective types for adults.Aims: We aimed to characterize the resistance of representative breathing systems and their components used in pediatric patients (including devices for adults) by their nonlinear pressure‐flow relationship.Methods: We used a physical model to measure the flow‐dependent pressure gradient (∆P) across breathing tubes, breathing tube extensions, 90°‐ and Y‐connectors, flow‐ and carbon dioxide sensors, water traps and reusable, disposable and coaxial breathing systems for pediatric and for adult patients. ∆P was analyzed for usual flow ranges and statistically compared at a representative flow rate of 300 mL∙s−1 (∆P300).Results: ∆P across pediatric devices always exceeded ∆P across the corresponding devices for adult patients (all P < .001 [no 95% CI includes 0]). ∆P300 across breathing system components for adults was always below 0.2 cmH2O but reached up to 4.6 cmH2O in a flow sensor for pediatric patients. ∆P300 was considerably higher across the reusable compared to the disposable pediatric breathing systems (1.9 vs 0.3 cmH2O, P < .001, [95% CI −1.59 to −1.56]).Conclusion: The resistances of pediatric breathing systems and their components result in pressure gradients exceeding those for adults several fold. Considering the resistance of individual components is crucial for composing a breathing system matching the patient's needs. Compensation of the additional resistance should be considered if a large composed resistance is unavoidable.


  • Comparative usability of modern anaesthesia ventilators: a human factors study

    by J. Spaeth, T. Schweizer, A. Schmutz, H. Buerkle, S. Schumann

    The anaesthesia ventilator represents the key equipment for intraoperative respiratory care. Improper operation of this device may threaten a patient’s health. A self-explanatory interface facilitates handling and decreases the risk of operating errors. This study systematically evaluates the usability of user interfaces in four modern anaesthesia ventilators. Twenty naïve operators were asked to execute 20 tasks on each of four different anaesthesia ventilators (Avance CS2™, GE Healthcare; Flow-i™, Maquet; and Perseus™ and Primus™, Dräger) in a randomized order. The success of task execution, frequency of requests for assistance, and processing times were recorded. During the tasks, the operators’ visual focus was measured via eye-tracking. Additionally, subjective assessments of usability were evaluated by a standardized questionnaire. For comparison, six experienced operators undertook the same protocol. The overall rate of falsely executed tasks was low. Naïve operators requested assistance least when using the Perseus (26). Pooled processing times were shortest for the Perseus (222 s), followed by the Primus (223 s), the Avance (238 s), and the Flow-i (353 s). Task-specific processing times differed considerably between the devices. Eye-tracking analyses revealed associated interface issues that impeded the operators’ performance. Operators rated usability best for the Perseus [mean (sd): 67 (17) arbitrary units] and worst for the Flow-i [50 (16) arbitrary units]. Results from experienced operators support these findings by trend. The usability of modern anaesthesia ventilators differs considerably. Interface issues of specific tasks impair the operator’s efficiency. Eliminating the specific usability issues might improve the operator’s performance and, as a consequence, the patient’s safety.