SIStephen Idem

Stephen Idem

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Stephen Idem has a total of 28 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    A Real-Time Output–Loss Method for Monitoring Heat Rate for Coal-Fired Power Plants

    by Joseph M. Staller, Robert P. M. Craven, Stephen Idem, Sastry Munukutla, Keith Kirkpatrick, Dudley Benton, Susan Eisenstadt, Karsten Kopperstad, Seth Leedy, Joe McHale, et al.

    This paper describes a real-time performance monitoring method based on PTC 4-2013 for determining instantaneous heat rates for coal-fired power plants. The calculation protocol uses a modified output–loss approach applied to a control volume that closely conforms to the boiler. The largest energy balance term is the heat transfer rate to the steam, which is known accurately in real-time when the plant employs properly calibrated instrumentation. The first-law energy balance also requires a balanced combustion equation which depends on coal composition, which is not known in real-time. A periodic or alert-driven calibration utilizes an ultimate analysis of a carefully collected coal sample and historic plant data obtained during the collection time of the coal sample. This is used to calculate correction factors for the coal mass flowrate, air preheater leakage, and CO2 and SO2 concentrations at the economizer exit derived from continuous emissions monitoring systems (CEMS) measurements performed at that location. The iterative calculations required to determine the coal composition in real-time are presented. The real-time performance algorithm exhibited significant sensitivity associated with measurements of the steam heat transfer rate, which was the dominant term in the overall boiler energy balance. Other input parameters generally yielded a much lower influence on calculated heat rate. It was concluded that for optimal accuracy of the output–loss method the steam and coal mass flowrates must be measured as accurately as possible.


  • Open Access

    Exploring a Variant of PTC 4-2013 for Real-Time Performance Monitoring of Fossil Fuel Power Plants

    by Joseph M. Staller, Robert P.M. Craven, Stephen Idem, Sastry Munukutla, Keith Kirkpatrick, Dudley Benton, Susan Eisenstadt, Karsten Kopperstad, Seth Leedy, Joe McHale, et al.

    This paper describes a real-time performance-monitoring method based on PTC 4-2013 that was developed for determining and reporting the annual heat rate for fossil fuel power plants. Unlike for the PTC 4 test, the coal composition is typically not known in real-time, so the procedure uses a modified output-loss approach applied to a control volume that closely conforms to the boiler. A calibration approach utilizes an ultimate analysis to describe the coal being burned during the calibration, while holding the plant load and other factors steady. This permits the calculation of correction factors used during real-time performance monitoring. Based on several assumptions that are justified within, a real-time estimate of coal composition is obtained. The losses are calculated in a similar manner to PTC 4-2013. However, the losses are expressed on a per-pound of as-fired coal basis, as opposed to a percentage of higher heating value of the coal, which is not known in real-time.


  • Open Access

    Pressure Loss Coefficients for VAV Terminal Units

    by Kiran Lankalapalli, Stephen Idem

    The goal of duct design is to deliver the proper quantity of conditioned air to various zones in a building as efficiently as possible. Duct design methods utilize predictions of total pressure loss through the duct system, instead of static pressure, since that is what dictates the fan energy needed to deliver the required air flow rate. Variable air volume (VAV) systems regulate

  • Open Access

    Unreinforced Flat Oval Duct Deformation Testing and Modeling

    by Stephen Idem, Avinash Paruchuri, Jane Liu

    The use of flat oval ducts is advantageous in those applications where space limitations do not allow the installation of round ducts. However, there is a tendency for flat oval ducts to exhibit excessive deflections when exposed to substantial positive/negative static gauge pressures, particularly when large flat spans are utilized. In those instances, it may be necessary to

  • Flat oval duct deflection-finite-element analysis

    by A. Paruchuri, V. Kurnool, J. Liu, S. Idem

    Finite-element models were developed to predict the deformation of unreinforced spiral flat oval ducts when subjected to a range of positive/negative internal gauge pressures. The models included the effects of duct self-weight. Deflection predictions resulting from a linear analysis and a nonlinear analysis were contrasted. This study also compared finite-element model predictions to experimentally derived spiral flat oval duct deflections, as well as duct deformations derived from a curve fit analysis reported previously in the literature. Close agreement between these results was obtained, thereby corroborating the nonlinear finite-element models that were generated in this study. This investigation emphasized the importance of utilizing nonlinear finite-element modeling to estimate the deflection of spiral flat oval ducts.

  • Modeling flow and pressure distributions in multi-branch light-commercial duct systems

    by C. Kodali, S. Idem

    This paper describes a numerical model that was developed to predict flow and pressure distribution in three multi-branch air duct systems as a function of upstream static gauge pressure. The duct systems were comprised of a combination of wire-wound flexible ducts and rigid sheet metal ducts. The model used the Darcy equation and the concept of the local loss coefficient, in conjunction with the continuity equation, to perform the calculations. The secant method was utilized to predict the flow rate through the initial upstream branch, and the Newton-Raphson method was employed model the flow through the remaining branches. The model demonstrated that the static gauge pressure rose in the overall flow direction due to the static regain effect, and that flow rate distribution varied in a predictable, characteristic manner in the overall flow direction. The model branch flow predictions were verified experimentally. The model is potentially useful for modeling the performance of variable air volume (VAV) air duct systems that use control strategies that depend on changing the fan speed and/or adjusting damper settings in the branches.


  • Open Access

    Determine the absolute roughness of phenolic duct (RP-1764)

    by Avinash Paruchuri, Stephen Idem

    An experimental program was conducted to measure the relative and absolute roughness of phenolic duct systems connected with a four-bolt flange and cleat joint. Ducts with seven distinct rectangular cross sections (internal aspect ratios ) were investigated. In every instance, the duct material thickness was 7/8 in. (22 mm), with smooth aluminum foil covering the internal surface between flanges. For unreinforced phenolic ducts with 10 ft (3.0 m) sections connected by four-bolt flanges, the relative roughness ɛ/Dh ranged from 0.0002 to 0.0005, with an average value of 0.0003. For similar ducts having 5 ft (1.5 m) duct sections (double the number of flanges per test section), the relative roughness range and average doubled. It appears that the flanges are the dominant effect on relative roughness and that the ducts tested have about 1.5 to 2.8 times more absolute roughness than the average value for galvanized steel ducts described in the ASHRAE Handbook.


  • A novel evaporative cooling tower constructed from an inflatable fabric duct

    by Steven Duong, Robert Craven, Steve Garner, Stephen Idem

    This paper describes a prototype of a novel vertical cooling tower constructed from an inflatable fabric duct that incorporated a water spray nozzle mounted at the top. The device was constructed using two concentric impermeable fabric tubes sealed at either end. It was inflated using a small pressurization fan located at the tower base. A numerical performance model was developed to estimate the downstream conditions of the evaporative cooling tower, and the length necessary for complete evaporation. To test the predictive capability the model of the evaporative cooling tower, experiments were performed under different ambient conditions. The prototype tower did exhibit downdraft cooling. However, the ambient conditions under which the validation measurements were performed were not conducive to achieving a moist air flow that could be measured accurately, and further investigation is recommended.


  • Open Access

    Experimental determination and computational fluid dynamics predictions of pressure loss in close-coupled elbows (RP-1682)

    by Mohammad Salehi, Stephen Idem, Ahmad Sleiti

    An experimental program was implemented to study pressure losses in HVAC duct systems associated with 305 mm (12 in.) diameter close-coupled round five-gore elbows. The goal of this program was to experimentally verify a computational fluid dynamics model to accurately predict pressure losses in order to design duct systems more effectively. The results of this study showed that the loss coefficient increased as a function of separation distance between the elbows in a Z-configuration and decreased in a U-configuration. For both 305 mm (12 in.) and 203 mm (8 in.) diameter elbows, power law expressions correlating the combination loss coefficient data as a function of intermediate length for close-coupled elbows arranged in a Z-configuration or a U-configuration were presented. Computational fluid dynamics modeling with enhanced wall treatment using the k-ϵ method was generally able to correctly predict elbow loss coefficients with an error of less than 15%.


  • Loss coefficients of bends in fully stretched nonmetallic flexible ducts

    by D. Kulkarni, Stephen Idem

    Zero-length loss coefficients were calculated for controlled bends of 45° and 90° in nonmetallic flexible ducts under fully stretched conditions for dimensionless bend radii of r/D = 1 and r/D = 1.5. The nominal duct diameters were 203, 305, and 356 mm (8, 12, and 14 in.). A regression analysis was performed on the measured data, and the uncertainties in the pressure loss coefficients were calculated. Correlations of loss coefficient data appropriate for insertion into a duct fitting database are presented.