Jingwei Zhu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Jingwei Zhu has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
Stefan Elbel
7 shared publicationsFrancesco Botticella
2 shared publicationsMichael Z. Q. Chen
Department of Mechanical Engineering, The University of Hong Kong, Hong Kong
2 shared publicationsBaozhu Du
School of Automation, Nanjing University of Science and Technology, China
1 shared publication- Baozhu Du
School of Information and Communication Engineering, Hainan University
1 shared publication - Stefan Elbel
Institute of Energy Engineering, Technische Universität Berlin, Berlin, Germany
1 shared publication
Latest Publications
- 3 April 2018
- Published by SAE International in SAE International Journal of Advances and Current Practices in Mobility
- Vol. 1
Implementation of Reinforcement Learning on Air Source Heat Pump Defrost Control for Full Electric Vehicles
Air source heat pumps as the heating system for full electric vehicles are drawing more and more attention in recent years. Despite the high energy efficiency, frost accumulation on the heat pump evaporator is one of the major challenges associated with air source heat pumps. The evaporator needs to be actively defrosted periodically and heat pump heating will be interrupted during defrosting process. Proper defrost control is needed to obtain high average heat pump energy efficiency. In this paper, a new method for generating air source heat pump defrost control policy using reinforcement learning is introduced. This model-free method has several advantages. It can automatically generate optimal defrost control policy instead of requiring manually determination of the control policy parameters and logics. More measurement results can be incorporated into the defrost control policy without too many changes in the reinforcement learning algorithm so that the control policy can be better optimized under wider range of working conditions. The learning features also enable the controller to adapt to the system differences and changes which are impossible to predict a priori when designing defrost control policy. The algorithm was validated using experimentally obtained heating capacity and COP data in frost growth cycle of a heat pump under different conditions. The results showed that reinforcement learning can be used to generate defrost control policy that optimizes energy consumption for various working conditions.
- 3 April 2018
- Published by SAE International in SAE International Journal of Advances and Current Practices in Mobility
- Vol. 1
Implementation of Reinforcement Learning on Air Source Heat Pump Defrost Control for Full Electric Vehicles
Air source heat pumps as the heating system for full electric vehicles are drawing more and more attention in recent years. Despite the high energy efficiency, frost accumulation on the heat pump evaporator is one of the major challenges associated with air source heat pumps. The evaporator needs to be actively defrosted periodically and heat pump heating will be interrupted during defrosting process. Proper defrost control is needed to obtain high average heat pump energy efficiency. In this paper, a new method for generating air source heat pump defrost control policy using reinforcement learning is introduced. This model-free method has several advantages. It can automatically generate optimal defrost control policy instead of requiring manually determination of the control policy parameters and logics. More measurement results can be incorporated into the defrost control policy without too many changes in the reinforcement learning algorithm so that the control policy can be better optimized under wider range of working conditions. The learning features also enable the controller to adapt to the system differences and changes which are impossible to predict a priori when designing defrost control policy. The algorithm was validated using experimentally obtained heating capacity and COP data in frost growth cycle of a heat pump under different conditions. The results showed that reinforcement learning can be used to generate defrost control policy that optimizes energy consumption for various working conditions.
- 3 April 2018
- Published by SAE International in SAE International Journal of Advances and Current Practices in Mobility
- Vol. 1
Oil Circulation Rate in Ejector Cooling Cycles
In this study, the influence of compressor speed, ejector motive nozzle needle position and evaporator inlet metering valve opening on the oil circulation rates (OCRs) of an automotive R744 transcritical standard ejector cycle was experimentally investigated. Significantly higher OCR (~10%) was observed at the evaporator inlet of the ejector cycle than at the high pressure side. It has been observed that evaporator OCR was increased with increasing compressor speed. When the motive nozzle needle moved towards the nozzle throat, both compressor discharge flow rate and evaporator OCR were observed to be significantly lowered. As the evaporator inlet metering valve opening was adjusted, the compressor mass flow rate did not vary significantly while the evaporator mass flow rate decreased with decreasing metering valve opening. The evaporator OCR decreased from 6.5% to 2.2% as the metering valve opening varied from 86% to 27%.
- 3 April 2018
- Published by SAE International in SAE International Journal of Advances and Current Practices in Mobility
- Vol. 1
Oil Circulation Rate in Ejector Cooling Cycles
In this study, the influence of compressor speed, ejector motive nozzle needle position and evaporator inlet metering valve opening on the oil circulation rates (OCRs) of an automotive R744 transcritical standard ejector cycle was experimentally investigated. Significantly higher OCR (~10%) was observed at the evaporator inlet of the ejector cycle than at the high pressure side. It has been observed that evaporator OCR was increased with increasing compressor speed. When the motive nozzle needle moved towards the nozzle throat, both compressor discharge flow rate and evaporator OCR were observed to be significantly lowered. As the evaporator inlet metering valve opening was adjusted, the compressor mass flow rate did not vary significantly while the evaporator mass flow rate decreased with decreasing metering valve opening. The evaporator OCR decreased from 6.5% to 2.2% as the metering valve opening varied from 86% to 27%.
- 3 April 2018
- Published by SAE International in SAE International Journal of Advances and Current Practices in Mobility
- Vol. 1
Application of Vortex Control to an Automotive Transcritical R744 Ejector Cycle
Expansion work recovery by two-phase ejector is known to be beneficial to vapor compression cycle performance. However, one of the biggest challenges with ejector vapor compression cycles is that the ejector cycle performance is sensitive to working condition changes which are common in automotive applications. Different working conditions require different ejector geometries to achieve maximum performance. Slightly different geometries may result in substantially different COPs under the same conditions. The ejector motive nozzle throat diameter (motive nozzle restrictiveness) is one of the key parameters that can significantly affect ejector cycle COP. This paper presents the experimental results of the application of a new two-phase nozzle restrictiveness control mechanism to an automotive transcritical R744 ejector cycle. This new control mechanism, vortex control, utilizes an adjustable vortex at the nozzle inlet to control the nozzle restrictiveness on the two-phase flow without changing the physical dimensions of the nozzle geometry. The test results show that nozzle restrictiveness can be adjusted with this new mechanism. Under common working conditions, with vortex control the ejector motive inlet pressure can be varied from 8609 kPa to 9637 kPa for constant motive inlet temperature and total motive mass flow rate.
- 3 April 2018
- Published by SAE International in SAE International Journal of Advances and Current Practices in Mobility
- Vol. 1
Application of Vortex Control to an Automotive Transcritical R744 Ejector Cycle
Expansion work recovery by two-phase ejector is known to be beneficial to vapor compression cycle performance. However, one of the biggest challenges with ejector vapor compression cycles is that the ejector cycle performance is sensitive to working condition changes which are common in automotive applications. Different working conditions require different ejector geometries to achieve maximum performance. Slightly different geometries may result in substantially different COPs under the same conditions. The ejector motive nozzle throat diameter (motive nozzle restrictiveness) is one of the key parameters that can significantly affect ejector cycle COP. This paper presents the experimental results of the application of a new two-phase nozzle restrictiveness control mechanism to an automotive transcritical R744 ejector cycle. This new control mechanism, vortex control, utilizes an adjustable vortex at the nozzle inlet to control the nozzle restrictiveness on the two-phase flow without changing the physical dimensions of the nozzle geometry. The test results show that nozzle restrictiveness can be adjusted with this new mechanism. Under common working conditions, with vortex control the ejector motive inlet pressure can be varied from 8609 kPa to 9637 kPa for constant motive inlet temperature and total motive mass flow rate.
- 28 March 2017
- Published by SAE International in SAE International Journal of Passenger Cars - Mechanical Systems
- Vol. 10 (1) , 121-127
Influence of Nozzle Divergent Part Length and Throat Diameter on Vortex Control of Initially Subcooled Flashing Flow
Expansion work recovery by two-phase ejector is known to be beneficial to vapor compression cycle performance. However, one of the biggest challenges with ejector vapor compression cycle is that the ejector cycle performance is sensitive to working condition changes which are common in many applications, including automotive AC systems. Different working conditions require different ejector geometries to achieve maximum performance. Slightly different geometries may result in substantially different COPs under the same conditions. Ejector motive nozzle throat diameter (motive nozzle restrictiveness) is one of the key parameters that can significantly affect COP. This paper presents the experimental investigation of a new motive nozzle restrictiveness control mechanism for two-phase ejectors used in vapor compression cycles, which has the advantages of being simple, potentially less costly and less vulnerable to clogging. The redesigned ejector utilizes an adjustable vortex at the motive inlet to control the nozzle restrictiveness on the flow expanded in the motive nozzle. Adjustable nozzles based on this new control mechanism were designed and manufactured for experiments with R134a. The influence of nozzle divergent part length and throat diameter on the vortex control of initially subcooled flashing flow is presented. Visualization results of the two-phase flow inside the nozzle are also provided.
- 28 March 2017
- Published by SAE International in SAE International Journal of Passenger Cars - Mechanical Systems
- Vol. 10 (1) , 121-127
Influence of Nozzle Divergent Part Length and Throat Diameter on Vortex Control of Initially Subcooled Flashing Flow
Expansion work recovery by two-phase ejector is known to be beneficial to vapor compression cycle performance. However, one of the biggest challenges with ejector vapor compression cycle is that the ejector cycle performance is sensitive to working condition changes which are common in many applications, including automotive AC systems. Different working conditions require different ejector geometries to achieve maximum performance. Slightly different geometries may result in substantially different COPs under the same conditions. Ejector motive nozzle throat diameter (motive nozzle restrictiveness) is one of the key parameters that can significantly affect COP. This paper presents the experimental investigation of a new motive nozzle restrictiveness control mechanism for two-phase ejectors used in vapor compression cycles, which has the advantages of being simple, potentially less costly and less vulnerable to clogging. The redesigned ejector utilizes an adjustable vortex at the motive inlet to control the nozzle restrictiveness on the flow expanded in the motive nozzle. Adjustable nozzles based on this new control mechanism were designed and manufactured for experiments with R134a. The influence of nozzle divergent part length and throat diameter on the vortex control of initially subcooled flashing flow is presented. Visualization results of the two-phase flow inside the nozzle are also provided.
- 5 April 2016
- Published by SAE International in SAE International Journal of Passenger Cars - Mechanical Systems
- Vol. 09 (1) , 44-51
A New Control Mechanism for Two-Phase Ejector in Vapor Compression Cycles for Automotive Applications Using Adjustable Motive Nozzle Inlet Swirl
Expansion work recovery by two-phase ejector is known to be beneficial to vapor compression cycle performance. However, one of the biggest challenges with ejector vapor compression cycles is that the ejector cycle performance is sensitive to working condition changes which are common in automotive applications. Different working conditions require different ejector geometries to achieve maximum performance. Slightly different geometries may result in substantially different COPs under the same conditions. The ejector motive nozzle throat diameter (motive nozzle restrictiveness) is one of the key parameters that can significantly affect ejector cycle COP. This paper presents a new two-phase nozzle restrictiveness control mechanism which is possibly applicable to two-phase ejectors used in vapor compression cycles. It utilizes an adjustable swirl at the nozzle inlet to control the nozzle restrictiveness on the two-phase flow without changing the physical dimensions of the nozzle geometry. This new control mechanism has the advantages of being simple and potentially less costly. It can possibly also avoid additional frictional losses of previously proposed ejector control mechanisms using an adjustable needle. An adjustable nozzle based on this new control mechanism was designed and manufactured for experiments with R134a. The experimental results showed that, without changing the nozzle geometry, the nozzle restrictiveness on the two-phase flow can be adjusted over a wide range. Under the same inlet and outlet conditions, the mass flow rate through the nozzle can be reduced by 36% of the full load. This feature could be very useful for the future application of ejectors in automotive systems under changing working conditions.
- 5 April 2016
- Published by SAE International in SAE International Journal of Passenger Cars - Mechanical Systems
- Vol. 09 (1) , 44-51
A New Control Mechanism for Two-Phase Ejector in Vapor Compression Cycles for Automotive Applications Using Adjustable Motive Nozzle Inlet Swirl
Expansion work recovery by two-phase ejector is known to be beneficial to vapor compression cycle performance. However, one of the biggest challenges with ejector vapor compression cycles is that the ejector cycle performance is sensitive to working condition changes which are common in automotive applications. Different working conditions require different ejector geometries to achieve maximum performance. Slightly different geometries may result in substantially different COPs under the same conditions. The ejector motive nozzle throat diameter (motive nozzle restrictiveness) is one of the key parameters that can significantly affect ejector cycle COP. This paper presents a new two-phase nozzle restrictiveness control mechanism which is possibly applicable to two-phase ejectors used in vapor compression cycles. It utilizes an adjustable swirl at the nozzle inlet to control the nozzle restrictiveness on the two-phase flow without changing the physical dimensions of the nozzle geometry. This new control mechanism has the advantages of being simple and potentially less costly. It can possibly also avoid additional frictional losses of previously proposed ejector control mechanisms using an adjustable needle. An adjustable nozzle based on this new control mechanism was designed and manufactured for experiments with R134a. The experimental results showed that, without changing the nozzle geometry, the nozzle restrictiveness on the two-phase flow can be adjusted over a wide range. Under the same inlet and outlet conditions, the mass flow rate through the nozzle can be reduced by 36% of the full load. This feature could be very useful for the future application of ejectors in automotive systems under changing working conditions.
- 5 April 2016
- Published by SAE International in SAE International Journal of Advances and Current Practices in Mobility
- Vol. 1
Vortex Tube Heat Booster to Improve Performance of Heat Driven Cooling Cycles for Automotive Applications
Increasing energy costs justify research on how to improve utilization of low-grade energy that is abundantly available as waste heat from many thermodynamic processes such as internal combustion engine cycles. One option is to directly generate cooling through absorption/adsorption or vapor jet ejector cycles. As in the case of power generation cycles, cooling cycle efficiencies would increase if the heat input were available at higher temperature. This paper assesses the feasibility of a novel idea that uses a vortex tube to increase the available temperature levels of low-grade heat sources. The desired temperature increase is achieved by sending a stream of vapor that was heated by the waste heat source through a vortex tube, which further elevates the temperature used in a heat driven ejector cooling cycle. Simulation results show that COP can be increased by 40% with the use of the vortex tube heat booster when the cycle is operating with low entrainment ratio at conditions where baseline performance and COP are low.
- 5 April 2016
- Published by SAE International in SAE International Journal of Advances and Current Practices in Mobility
- Vol. 1
Vortex Tube Heat Booster to Improve Performance of Heat Driven Cooling Cycles for Automotive Applications
Increasing energy costs justify research on how to improve utilization of low-grade energy that is abundantly available as waste heat from many thermodynamic processes such as internal combustion engine cycles. One option is to directly generate cooling through absorption/adsorption or vapor jet ejector cycles. As in the case of power generation cycles, cooling cycle efficiencies would increase if the heat input were available at higher temperature. This paper assesses the feasibility of a novel idea that uses a vortex tube to increase the available temperature levels of low-grade heat sources. The desired temperature increase is achieved by sending a stream of vapor that was heated by the waste heat source through a vortex tube, which further elevates the temperature used in a heat driven ejector cooling cycle. Simulation results show that COP can be increased by 40% with the use of the vortex tube heat booster when the cycle is operating with low entrainment ratio at conditions where baseline performance and COP are low.
- 1 June 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 07431619,p. 2912-2917
A new pricing scheme for controlling energy storage devices in smart grid
Improvement of the overall efficiency of energy infrastructure is one of the main anticipated benefits of the deployment of smart grid technology. Advancement in energy storage technology and two-way communication in the electric network are indispensable components to achieve such a vision, while efficient pricing schemes and appropriate storage management are also essential. In this paper, we propose a novel pricing scheme which permits one to indirectly control the energy storage devices in the grid to achieve a more desirable aggregate demand profile that meets a particular target of the grid operator such as energy generation cost minimization and carbon emission reduction. Such a pricing scheme can potentially be applied to control the behavior of energy storage devices installed for integration of intermittent renewable energy sources that have permission to grid connection and will have broader applications as an increasing number of novel and low-cost energy storage technologies emerge.
- 1 June 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 07431619,p. 2912-2917
A new pricing scheme for controlling energy storage devices in smart grid
Improvement of the overall efficiency of energy infrastructure is one of the main anticipated benefits of the deployment of smart grid technology. Advancement in energy storage technology and two-way communication in the electric network are indispensable components to achieve such a vision, while efficient pricing schemes and appropriate storage management are also essential. In this paper, we propose a novel pricing scheme which permits one to indirectly control the energy storage devices in the grid to achieve a more desirable aggregate demand profile that meets a particular target of the grid operator such as energy generation cost minimization and carbon emission reduction. Such a pricing scheme can potentially be applied to control the behavior of energy storage devices installed for integration of intermittent renewable energy sources that have permission to grid connection and will have broader applications as an increasing number of novel and low-cost energy storage technologies emerge.
- Open Access
- 1 January 2014
- Published by Wiley in Journal of Applied Mathematics
- Vol. 2014, 1-11
A New Pricing Scheme for Controlling Energy Storage Devices in Future Smart Grid
Improvement of the overall efficiency of energy infrastructure is one of the main anticipated benefits of the deployment of smart grid technology. Advancement in energy storage technology and two-way communication in the electric network are indispensable components to achieve such a vision, while efficient pricing schemes and appropriate storage management are also essential. In this paper, we propose a universal pricing scheme which permits one to indirectly control the energy storage devices in the grid to achieve a more desirable aggregate demand profile that meets a particular target of the grid operator such as energy generation cost minimization and carbon emission reduction. Such a pricing scheme can potentially be applied to control the behavior of energy storage devices installed for integration of intermittent renewable energy sources that have permission to grid connection and will have broader applications as an increasing number of novel and low-cost energy storage technologies emerge.
- 1 January 2014
- Published by Wiley in Journal of Applied Mathematics
- Vol. 2014, 1-11
Open AccessA New Pricing Scheme for Controlling Energy Storage Devices in Future Smart Grid
Improvement of the overall efficiency of energy infrastructure is one of the main anticipated benefits of the deployment of smart grid technology. Advancement in energy storage technology and two-way communication in the electric network are indispensable components to achieve such a vision, while efficient pricing schemes and appropriate storage management are also essential. In this paper, we propose a universal pricing scheme which permits one to indirectly control the energy storage devices in the grid to achieve a more desirable aggregate demand profile that meets a particular target of the grid operator such as energy generation cost minimization and carbon emission reduction. Such a pricing scheme can potentially be applied to control the behavior of energy storage devices installed for integration of intermittent renewable energy sources that have permission to grid connection and will have broader applications as an increasing number of novel and low-cost energy storage technologies emerge.