Veli Yenil
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Veli Yenil has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Sevilay Cetin
Pamukkale Universitesi
5 shared publications - Hasan Çimen
Department of Electrical and Electronic Engineering, Afyon Kocatepe University 2 , Afyonkarahisar
3 shared publications - İsMail Yabanova
Department of Electrical Engineering, Manisa Celal Bayar University 3 , Manisa
3 shared publications - Recep Akkan
Kutahya Dumlupinar Universitesi
2 shared publications - Recep Akkan
Department of Electronics and Automation, Kütahya Dumlupınar University 1 , Kütahya
1 shared publication - Sadık Özdemir
Pamukkale Universitesi
1 shared publication
Latest Publications
- 1 May 2026
- Published by AIP Publishing in Journal of Renewable and Sustainable Energy
- Vol. 18 (3)
Application of characteristic curves appropriate for relay coordination in adaptive protection networks containing distributed generation facilities
The integration of distributed generation (DG) facilities into power grids improves energy supply but introduces significant complexity, particularly with respect to protection coordination. Since power output from most DG facilities depends on variable conditions such as wind speed and solar irradiance, the magnitude of short-circuit currents that arise during faults also varies continuously. This variability causes deterioration of overcurrent relay coordination and selectivity, potentially leading to unnecessary power outages and equipment damage. To address this challenge, this study proposes an adaptive protection algorithm that selects the most appropriate relay time-current characteristic curve based on the real-time connection status of DG facilities to the network. The algorithm distinguishes among eight operating modes defined by the on/off states of three DG units and assigns either the standard inverse or extremely inverse characteristic curve accordingly. The proposed method was implemented and validated in a MATLAB/Simulink environment using a modified IEEE 4-bus test system integrated with three squirrel-cage induction generator-based wind turbines. Performance was evaluated across 24 scenarios comprising 8 operating modes and 3 fault locations. Simulation results demonstrate that the proposed algorithm reduces the tripping time of backup relays in 20 out of 24 cases, with improvements ranging from 29.11% to 90.98% compared to conventional adaptive protection. These findings confirm that the proposed method significantly enhances relay coordination, selectivity, and system protection in DG-integrated networks.
- 1 May 2026
- Published by AIP Publishing in Journal of Renewable and Sustainable Energy
- Vol. 18 (3)
Application of characteristic curves appropriate for relay coordination in adaptive protection networks containing distributed generation facilities
The integration of distributed generation (DG) facilities into power grids improves energy supply but introduces significant complexity, particularly with respect to protection coordination. Since power output from most DG facilities depends on variable conditions such as wind speed and solar irradiance, the magnitude of short-circuit currents that arise during faults also varies continuously. This variability causes deterioration of overcurrent relay coordination and selectivity, potentially leading to unnecessary power outages and equipment damage. To address this challenge, this study proposes an adaptive protection algorithm that selects the most appropriate relay time-current characteristic curve based on the real-time connection status of DG facilities to the network. The algorithm distinguishes among eight operating modes defined by the on/off states of three DG units and assigns either the standard inverse or extremely inverse characteristic curve accordingly. The proposed method was implemented and validated in a MATLAB/Simulink environment using a modified IEEE 4-bus test system integrated with three squirrel-cage induction generator-based wind turbines. Performance was evaluated across 24 scenarios comprising 8 operating modes and 3 fault locations. Simulation results demonstrate that the proposed algorithm reduces the tripping time of backup relays in 20 out of 24 cases, with improvements ranging from 29.11% to 90.98% compared to conventional adaptive protection. These findings confirm that the proposed method significantly enhances relay coordination, selectivity, and system protection in DG-integrated networks.
- 31 March 2026
- Published by Journal of the Faculty of Engineering and Architecture of Gazi University in Gazi Üniversitesi Mühendislik-Mimarlık Fakültesi Dergisi
- Vol. 41 (1) , 719-730
Dağıtık üretim tesisleri içeren adaptif korumadaki şebekelerde yeni bir röle koordinasyonu uygulaması
Elektrik dağıtım hatlarının korunması konusu günümüzde popüler olan akıllı şebekelerde olmazsa olmaz bir durumdur. Elektrik dağıtım hatlarının ise gelecekte yetersiz kalacak olması dağıtım hatlarına Dağıtık Üretimlerin (DÜ) bağlanmasını kaçınılmaz kılmaktadır. Elektrik dağıtım hatlarına gün geçtikçe artan bir şekilde DÜ ünitelerinin bağlanması birçok fayda sağlarken bir o kadar da dağıtım hattını karmaşık bir yapıya büründürmektedir. Bu durum elektrik dağıtım hatlarının korunmasını bir derece daha zorlaştırmaktadır. Rüzgâr enerjisi vb. DÜ tesislerinde enerjinin üretimi atmosfer şartlarına bağımlı olduğundan bu durum şebekede oluşabilecek kısa devre akımlarını doğrudan etkilemektedir. Bu sorunlar belirli bir koordinasyonda çalışan rölelerin yanlış çalışmasına, iki rölenin aynı anda çalışmasına (selektivite sağlanamadığından), gereksiz enerji kesintisi gibi durumlara yol açabilmektedir. Bu sorunların önüne geçmek için ise akıllı şebekelerde çift yönlü adaptif korumaya ve buna uygun şekilde çalışacak algoritmalara ihtiyaç duyulmaktadır. Bu çalışmada bahsedilen korumaya uygun bir algoritma önerilmiştir. Günümüz koşullarına ve orijinaline uygun bir şekilde değiştirilen IEEE 4-baralı test sistemi üzerinde yapılan simülasyon çalışmaları önerilen algoritma ile rölelerin daha doğru bir şekilde çalışmasına olanak sağlamıştır. Böylece önerilen algoritma ile çalışan adaptif korumadaki yedek rölelerin çalışması ile normal adaptif korumadaki yedek rölelerin çalışması karşılaştırılmış ve sonuçlar sunulmuştur.
- 31 March 2026
- Published by Journal of the Faculty of Engineering and Architecture of Gazi University in Gazi Üniversitesi Mühendislik-Mimarlık Fakültesi Dergisi
- Vol. 41 (1) , 719-730
Dağıtık üretim tesisleri içeren adaptif korumadaki şebekelerde yeni bir röle koordinasyonu uygulaması
Elektrik dağıtım hatlarının korunması konusu günümüzde popüler olan akıllı şebekelerde olmazsa olmaz bir durumdur. Elektrik dağıtım hatlarının ise gelecekte yetersiz kalacak olması dağıtım hatlarına Dağıtık Üretimlerin (DÜ) bağlanmasını kaçınılmaz kılmaktadır. Elektrik dağıtım hatlarına gün geçtikçe artan bir şekilde DÜ ünitelerinin bağlanması birçok fayda sağlarken bir o kadar da dağıtım hattını karmaşık bir yapıya büründürmektedir. Bu durum elektrik dağıtım hatlarının korunmasını bir derece daha zorlaştırmaktadır. Rüzgâr enerjisi vb. DÜ tesislerinde enerjinin üretimi atmosfer şartlarına bağımlı olduğundan bu durum şebekede oluşabilecek kısa devre akımlarını doğrudan etkilemektedir. Bu sorunlar belirli bir koordinasyonda çalışan rölelerin yanlış çalışmasına, iki rölenin aynı anda çalışmasına (selektivite sağlanamadığından), gereksiz enerji kesintisi gibi durumlara yol açabilmektedir. Bu sorunların önüne geçmek için ise akıllı şebekelerde çift yönlü adaptif korumaya ve buna uygun şekilde çalışacak algoritmalara ihtiyaç duyulmaktadır. Bu çalışmada bahsedilen korumaya uygun bir algoritma önerilmiştir. Günümüz koşullarına ve orijinaline uygun bir şekilde değiştirilen IEEE 4-baralı test sistemi üzerinde yapılan simülasyon çalışmaları önerilen algoritma ile rölelerin daha doğru bir şekilde çalışmasına olanak sağlamıştır. Böylece önerilen algoritma ile çalışan adaptif korumadaki yedek rölelerin çalışması ile normal adaptif korumadaki yedek rölelerin çalışması karşılaştırılmış ve sonuçlar sunulmuştur.
- 17 February 2026
- Published by Gazi Universitesi Fen Bilimleri Dergisi Part C: Tasarim ve Teknoloji in Gazi Üniversitesi Fen Bilimleri Dergisi Part C: Tasarım ve Teknoloji
- Vol. 14 (1) , 116-127
Design and Implementation of Receiver Side Buck Converter Based Wireless Charging System for AGVs
In this study, the design, control, and implementation of a wireless power transfer (WPT) charging system for automated guided vehicles (AGVs) are proposed. An LCC-S tuned resonant network is designed for the proposed WPT system. Subsequently, the coupling coil design is provided through the finite element analysis simulation. By using the dc-dc buck converter on the receiver side, the constant current (CC) and constant voltage (CV) control of the WPT charging system are also achieved. The benefits of the proposed WPT charging system based on receiver side control with a dc-dc buck converter are demonstrated by simulation and experimental studies. To test the performance of the proposed control approach, a 300 W WPT prototype was built with an air gap of 50 mm. According to experimental results, the proposed WPT system has successfully maintained CC and CV charging for AGVs with various load conditions.
- 17 February 2026
- Published by Gazi Universitesi Fen Bilimleri Dergisi Part C: Tasarim ve Teknoloji in Gazi Üniversitesi Fen Bilimleri Dergisi Part C: Tasarım ve Teknoloji
- Vol. 14 (1) , 116-127
Design and Implementation of Receiver Side Buck Converter Based Wireless Charging System for AGVs
In this study, the design, control, and implementation of a wireless power transfer (WPT) charging system for automated guided vehicles (AGVs) are proposed. An LCC-S tuned resonant network is designed for the proposed WPT system. Subsequently, the coupling coil design is provided through the finite element analysis simulation. By using the dc-dc buck converter on the receiver side, the constant current (CC) and constant voltage (CV) control of the WPT charging system are also achieved. The benefits of the proposed WPT charging system based on receiver side control with a dc-dc buck converter are demonstrated by simulation and experimental studies. To test the performance of the proposed control approach, a 300 W WPT prototype was built with an air gap of 50 mm. According to experimental results, the proposed WPT system has successfully maintained CC and CV charging for AGVs with various load conditions.
- 31 December 2025
- Published by Gazi University in Gazi University Journal of Science Part A: Engineering and Innovation
- Vol. 12 (4) , 1028-1043
Extended State Observer Based Improved Control of Interleaved Boost Converter
The interleaved boost converters used in fuel cell (FC) applications are inevitably affected by disturbances, making output voltage regulation challenging. To address this issue, this paper proposes an improved robust voltage control strategy based on an extended state observer (ESO), which is implemented in interleaved DC-DC converters for FC systems. The super-twisting (ST) algorithm is used to track reference current in the inner loop. In the outer loop design, an ESO based controller is used to ensure output voltage regulation while generating the reference current required for the inner loop. Simulation results are used to verify the performance and robustness of the proposed controller, with comparison against the conventional double-loop PI controller.
- 31 December 2025
- Published by Gazi University in Gazi University Journal of Science Part A: Engineering and Innovation
- Vol. 12 (4) , 1028-1043
Extended State Observer Based Improved Control of Interleaved Boost Converter
The interleaved boost converters used in fuel cell (FC) applications are inevitably affected by disturbances, making output voltage regulation challenging. To address this issue, this paper proposes an improved robust voltage control strategy based on an extended state observer (ESO), which is implemented in interleaved DC-DC converters for FC systems. The super-twisting (ST) algorithm is used to track reference current in the inner loop. In the outer loop design, an ESO based controller is used to ensure output voltage regulation while generating the reference current required for the inner loop. Simulation results are used to verify the performance and robustness of the proposed controller, with comparison against the conventional double-loop PI controller.
- 26 December 2025
- Published by Journal of Materials and Mechatronics: A in Journal of Materials and Mechatronics: A
- Vol. 6 (2) , 366-380
Overcurrent Relay Coordination in Adaptive Protected Networks with Integrated Wind Energy
The fact that the capacity of electricity distribution networks will be insufficient in the future has forced people to integrate DG (Distributed Generation) facilities into their distribution networks. Although DG facilities provide many benefits to the grid, they also lead to complexity in the distribution network. This situation not only makes it difficult to protect the distribution network but also causes short circuit currents to have a variable structure. Variable short circuit currents cause the relays to activate at the wrong time, causing OCR (Overcurrent Relay) coordination to be disrupted. For this reason, bidirectional relays and adaptive protection are needed in the networks. In this study, the IEEE 4-bus test system, which includes DG facilities and was created in accordance with its original form, was used for simulation studies. In this way, the effect of short circuit current variability is minimized and optimum protection is achieved by quickly adapting to variable network conditions.
- 26 December 2025
- Published by Journal of Materials and Mechatronics: A in Journal of Materials and Mechatronics: A
- Vol. 6 (2) , 366-380
Overcurrent Relay Coordination in Adaptive Protected Networks with Integrated Wind Energy
The fact that the capacity of electricity distribution networks will be insufficient in the future has forced people to integrate DG (Distributed Generation) facilities into their distribution networks. Although DG facilities provide many benefits to the grid, they also lead to complexity in the distribution network. This situation not only makes it difficult to protect the distribution network but also causes short circuit currents to have a variable structure. Variable short circuit currents cause the relays to activate at the wrong time, causing OCR (Overcurrent Relay) coordination to be disrupted. For this reason, bidirectional relays and adaptive protection are needed in the networks. In this study, the IEEE 4-bus test system, which includes DG facilities and was created in accordance with its original form, was used for simulation studies. In this way, the effect of short circuit current variability is minimized and optimum protection is achieved by quickly adapting to variable network conditions.
- 8 July 2025
- Published by Springer Nature in Journal of Power Electronics
- Vol. 26 (4) , 920-933
Robust output voltage controller for dynamic wireless charging of electric vehicles based on super-twisting algorithm
- 8 July 2025
- Published by Springer Nature in Journal of Power Electronics
- Vol. 26 (4) , 920-933
Robust output voltage controller for dynamic wireless charging of electric vehicles based on super-twisting algorithm
- 25 June 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 13 (5) , 6780-6790
Composite Control Strategy for Constant Output Regulation of Dynamic Wireless Charging System in Electric Vehicles
This paper proposes a novel control scheme for the output voltage regulation of electrical vehicles (EVs) dynamic wireless charging (DWC) systems based on integral terminal sliding mode control (ITSMC) and finite time disturbance observer (FTDO). In the DWC system, due to EV movement, the coupling coefficient between primary and secondary coils varies, which leads to severe output voltage fluctuation in the DWC system. Thus, the wireless charging performance of the DWC system deteriorates. In order to compensate for the disturbances arising from the coupling coefficient variation and load resistance uncertainties, a disturbance observer-based ITSMC control strategy is proposed for the secondary side of the DWC system. In order to verify the effectiveness of the proposed control, a DWC prototype is built. Then, the proposed FTDO-based ITSMC and double proportional-integral (PI) control methods are compared with both simulation and experiments. The results verify that the proposed control could reduce the DWC system output voltage fluctuation from 5.27% to 1.66% compared to the conventional double PI control.
- 25 June 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 13 (5) , 6780-6790
Composite Control Strategy for Constant Output Regulation of Dynamic Wireless Charging System in Electric Vehicles
This paper proposes a novel control scheme for the output voltage regulation of electrical vehicles (EVs) dynamic wireless charging (DWC) systems based on integral terminal sliding mode control (ITSMC) and finite time disturbance observer (FTDO). In the DWC system, due to EV movement, the coupling coefficient between primary and secondary coils varies, which leads to severe output voltage fluctuation in the DWC system. Thus, the wireless charging performance of the DWC system deteriorates. In order to compensate for the disturbances arising from the coupling coefficient variation and load resistance uncertainties, a disturbance observer-based ITSMC control strategy is proposed for the secondary side of the DWC system. In order to verify the effectiveness of the proposed control, a DWC prototype is built. Then, the proposed FTDO-based ITSMC and double proportional-integral (PI) control methods are compared with both simulation and experiments. The results verify that the proposed control could reduce the DWC system output voltage fluctuation from 5.27% to 1.66% compared to the conventional double PI control.
- Open Access
- 30 September 2024
- Published by Gazi University in Gazi University Journal of Science Part A: Engineering and Innovation
- Vol. 11 (3) , 563-576
Super Twisting Sliding Mode Control of Four-Phase Interleaved Boost Converter
This paper presents a novel control method that integrates super-twisting sliding mode (STSM) voltage control with proportional-integral (PI) current control for a four-phase interleaved boost converter (IBC) in fuel cell applications. The STSM control, employed in the outer voltage loop, provides robust voltage regulation by generating precise reference currents for each phase. The conventional PI control in the inner current loop utilizes these reference currents to generate pulse width modulation (PWM) signals for each phase. The effectiveness of the proposed control strategy is evaluated through comprehensive simulation studies in MATLAB/Simulink, demonstrating an improvement in dynamic performance and enhanced robustness compared to conventional methods. Quantitative analysis shows that the output voltage quickly rises to the reference voltage within approximately 0.25 seconds in the proposed STSM-PI control method and improves transient response by 16 times compared to the conventional PI-PI method. This integrated STSM-PI control strategy offers significant advancements in reliability and efficiency making it a promising solution for high-performance fuel cell power systems.
- 30 September 2024
- Published by Gazi University in Gazi University Journal of Science Part A: Engineering and Innovation
- Vol. 11 (3) , 563-576
Open AccessSuper Twisting Sliding Mode Control of Four-Phase Interleaved Boost Converter
This paper presents a novel control method that integrates super-twisting sliding mode (STSM) voltage control with proportional-integral (PI) current control for a four-phase interleaved boost converter (IBC) in fuel cell applications. The STSM control, employed in the outer voltage loop, provides robust voltage regulation by generating precise reference currents for each phase. The conventional PI control in the inner current loop utilizes these reference currents to generate pulse width modulation (PWM) signals for each phase. The effectiveness of the proposed control strategy is evaluated through comprehensive simulation studies in MATLAB/Simulink, demonstrating an improvement in dynamic performance and enhanced robustness compared to conventional methods. Quantitative analysis shows that the output voltage quickly rises to the reference voltage within approximately 0.25 seconds in the proposed STSM-PI control method and improves transient response by 16 times compared to the conventional PI-PI method. This integrated STSM-PI control strategy offers significant advancements in reliability and efficiency making it a promising solution for high-performance fuel cell power systems.
- Open Access
- 17 September 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 12, 134937-134947
A Wireless Power Transfer System With High Misalignment Tolerance Based on Dual Side Variable Inductor Control
This article presents an LCC-LCC wireless power transfer (WPT) system based on dual side variable inductor (VI) control to achieve high efficiency and output power regulation. By adjusting the inductances of the VIs, the output voltage and current can be controlled while the wide range of zero voltage switching (ZVS) can be achieved for the primary side inverter under different misalignment conditions. The VIs in the primary and secondary sides provides ZVS condition and output regulation against misalignment, respectively. Since the resonant inductors of LCC-LCC topology are designed as VIs, the use of additional compensation elements is also eliminated. Moreover, the wireless communication is not necessary between primary and secondary side. A 300 W prototype is developed to verify the effectiveness of the proposed control method. Experimental results demonstrate that good regulation performance and high transmission efficiency are provided for the WPT system under the wide range of misalignment. A maximum efficiency of 92.5 % has been achieved for the proposed WPT system under the full power output.
- 17 September 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 12, 134937-134947
Open AccessA Wireless Power Transfer System With High Misalignment Tolerance Based on Dual Side Variable Inductor Control
This article presents an LCC-LCC wireless power transfer (WPT) system based on dual side variable inductor (VI) control to achieve high efficiency and output power regulation. By adjusting the inductances of the VIs, the output voltage and current can be controlled while the wide range of zero voltage switching (ZVS) can be achieved for the primary side inverter under different misalignment conditions. The VIs in the primary and secondary sides provides ZVS condition and output regulation against misalignment, respectively. Since the resonant inductors of LCC-LCC topology are designed as VIs, the use of additional compensation elements is also eliminated. Moreover, the wireless communication is not necessary between primary and secondary side. A 300 W prototype is developed to verify the effectiveness of the proposed control method. Experimental results demonstrate that good regulation performance and high transmission efficiency are provided for the WPT system under the wide range of misalignment. A maximum efficiency of 92.5 % has been achieved for the proposed WPT system under the full power output.
- 4 April 2022
- Published by Springer Nature in Electrical Engineering
- Vol. 104 (5) , 3197-3206
High efficiency implementation of constant voltage control of LC/S compensated wireless charging system for stationary electrical vehicles
- 4 April 2022
- Published by Springer Nature in Electrical Engineering
- Vol. 104 (5) , 3197-3206
High efficiency implementation of constant voltage control of LC/S compensated wireless charging system for stationary electrical vehicles