WZWei Zhuang

Wei Zhuang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Wei Zhuang has a total of 24 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    The Coupling Effects of Thermosetting Polyurethane Crosslinking and an Aggregate Skeleton on the Mechanical Response of Asphalt Mixtures

    by Deshui Yu, Wei Zhuang, Baoju Liu, Xiaowei Liu, Run Xu, Dan Wang, Zhuoran Yan, Min Sun

    To clarify the coupled effects of the thermosetting polyurethane (PU) crosslinked binder network and aggregate gradation on the multi-mode mechanical response of asphalt mixtures, three representative 13 mm gradations—stone mastic asphalt (SMA-13), dense-skeleton asphalt concrete (SAC-13), and dense-graded asphalt concrete (AC-13)—were used to prepare polyurethane-modified asphalt (PUA) mixtures, with an SMA-13 styrene–butadiene–styrene (SBS)-modified asphalt mixture employed as the control. Uniaxial penetration and dynamic modulus tests were conducted to systematically characterize strength, deformation, fracture, and viscoelastic responses under direct tension, crack propagation, localized compression–shear loading, and cyclic loading. Under the same SMA gradation and binder–aggregate ratio, SMA-PUA exhibited a 212.5% increase in peak tensile stress, a 29.2% reduction in peak strain, and increases of 76.3% and 92.8% in penetration strength and the penetration modulus, respectively, relative to SMA-SBS, demonstrating the enhanced load-bearing and stress transfer capacity provided by the three-dimensional PU chemical network. Gradation had a limited influence on tensile strength but a pronounced effect on penetration and fracture behavior. In terms of penetration strength and the penetration modulus, the mixtures followed the order SAC-PUA > SMA-PUA > AC-PUA, the SCB maximum fracture strength followed the same order and the maximum tensile strain showed the reverse trend. Dynamic testing showed clear temperature–frequency dependence for all PUA mixtures, with SAC-PUA generally maintaining higher dynamic stiffness. At the common test temperature of 35 °C, SMA-PUA exhibited a higher dynamic modulus and a smaller, more stable phase angle than SMA-SBS. Overall, the macroscopic mechanical response of thermosetting PUA mixtures is governed by the synergy between the high-strength crosslinked binder network and the aggregate skeleton: the PU network establishes the basic load-bearing level, while gradation further regulates stiffness, crack propagation, and deformation compatibility.

  • Open Access

    Mechanical Properties and Modification Mechanism of Thermosetting Polyurethane-Modified Asphalt

    by Wei Zhuang, Tingting Ding, Chuanqin Pang, Xuwang Jiao, Litao Geng, Min Sun

    To study the mechanical properties and modification mechanism of thermosetting polyurethane (PU)-modified asphalt, the effects of polyurethane dosage on the workability of polyurethane-modified asphalt were analyzed by means of rotational viscosity tests. The mechanical properties of polyurethane-modified asphalt with different polyurethane dosages were explored using tensile tests and dynamic mechanical analysis (DMA). In addition, the thermodynamic behavior and micromorphology of polyurethane-modified asphalt were also thoroughly investigated using the test results of differential scanning calorimetry (DSC) and scanning electron microscopy (SEM). The results showed that PU obtained the optimum workability when the polyurethane dose was 50%: at 120 min, its rotational viscosity was 1005 cp, which was lower than 2800 cp (40% PU) and 760 cp (60% PU). Additionally, the results of fracture elongation and fracture strength indicated that the PU-modified asphalt had good flexibility and strength. Compared with base asphalt, the tensile strength of 50% PU-modified asphalt increased by 509%, which was significantly higher than 157% (40% PU) and more balanced than 897% (60% PU) in terms of strength and flexibility. Added PU can significantly improve the elasticity of asphalt at high temperatures, while increasing the proportion of asphalt adhesive components, enhancing the deformation ability and temperature stability of asphalt. As the dose of PU increases, the interface between asphalt and PU blended more fully, and the surface became smoother. When the dose of PU was 50% or more, the interface between asphalt and PU was well integrated with a smooth and flat surface, forming a more uniform and stable cross-linked network structure.


  • Open Access

    Modification Mechanism and Performance of High-Content Polyurethane-Modified Asphalt

    by Wei Zhuang, Shuaiyu Ren, Baoju Liu, Tingting Ding, Lizheng Liu, Luyao Gu, Min Sun

    To explore the influence of the polyurethane blending ratio on the micro-characteristics of polyurethane-modified asphalt, three samples of the modified asphalt with different blending ratios (40%, 50%, and 60%) were prepared. Fourier transform infrared spectroscopy (FTIR), atomic force microscopy (AFM), and scanning electron microscopy (SEM) were employed to elucidate the modification mechanism of polyurethane-modified asphalt. To investigate how the preparation method affects the performance of polyurethane-modified asphalt mixtures, two different preparation methods, namely internal blending and external blending, were adopted. The road performance of the polyurethane-modified asphalt mixtures was evaluated through the utilization of rutting tests, low-temperature trabecular bending tests, and freeze–thaw splitting tests. The FTIR test results indicate that during the modification of polyurethane, there is a change in both the intensity and position of the absorption peak, which affects the local arrangement of the molecular structure. Upon reaching a polyurethane blending ratio of 50%, a cross-linked network structure that is similar to polyurethane is formed. The results of the AFM test demonstrate that an increase in polyurethane content results in a corresponding increase in surface roughness. At a polyurethane content of 50%, the curing reaction is most effective, which is beneficial for enhancing the bonding performance between the asphalt and the aggregate, thereby enhancing the overall water stability of the mixture. The results of the scanning electron microscopy (SEM) tests indicate that the microstructure is more stable when the polyurethane content is 50%. The results of the performance test of the polyurethane-modified asphalt mixture indicate that the dynamic stability of the polyurethane-modified asphalt mixture is approximately four times that of the SBS-modified asphalt mixture. The flexural tensile strength and maximum flexural strain of the polyurethane-modified asphalt mixture are, respectively, 1.5 and 3.2 times those of the SBS-modified asphalt mixture, indicating that its anti-deformation ability is stronger in a low-temperature environment, and it is found that the low-temperature performance of the mixture prepared with the internal blending method is better than that with the external blending method. The splitting strength of the polyurethane asphalt mixture before and after freezing and thawing is greater than that of an SBS asphalt mixture: before freezing and thawing, by about 3.8 times; after freezing and thawing, by about 3 times. Although the freezing and thawing of the polyurethane mixture has damage, it still meets the requirements of the use of pavement materials. It can be observed that the incorporation of polyurethane alters the internal structure of the asphalt, which markedly enhances the properties of the asphalt mixture and offers a novel perspective on the development of modified asphalt materials.


  • Open Access

    Mechanical Properties of Polyurethane Mixture and Load Response Behaviour of Polyurethane Composite Pavement

    by Wei Zhuang, Yufeng Bi, Baoju Liu, Derui Hou, Shuo Jing, Xiaojin Lu, Min Sun

    Finite element numerical simulation calculation of pavement structure load response is widely applied; however, there is still a lack of research on the polyurethane (PU) mixture composite pavement load response. The mechanical characteristics of PU mixture composite pavement are not well understood, and there is a lack of research on typical pavement structures of PU mixtures, which limits their application in pavement structures. Therefore, herein, the mechanical properties of PU mixtures are analysed using the dynamic modulus test, uniaxial penetration test, and fatigue test. Further, the finite element theory calculation method is used to realize the load response calculation of orthogonal design composite pavement structure. The results show that PU mixtures exhibit more obvious elastic characteristics and have good shear resistance, fatigue stability, and temperature stability, and can be used as shear and anti-fatigue layers. The structure of ‘4 cm SMA-13 + 5 cm PUM-20 + 6 cm PUM-25 + semi-rigid base’ is recommended for the PU mixture composite structure. In comparison to typical asphalt pavement, the analysis shows that except for shear stress, temperature has little effect on the load response of PU composite pavement structures, while high temperatures lead to a significant increase in the load response of typical asphalt pavement structures. The PU composite pavement can bear greater loads and has a reduced thickness of its surface layer by about 3 cm in comparison to conventional pavement. The results of this study provide theoretical support for the design of PU mixture pavement structures and promote the popularization and application of PU mixture pavement.


  • Open Access

    Interlaminar Shear Characteristics, Energy Consumption, and Carbon Emissions of Polyurethane Mixtures

    by Yufeng Bi, Min Sun, Shuo Jing, Derui Hou, Wei Zhuang, Sai Chen, Xuwang Jiao, Quanman Zhao

    The interlaminar shear characteristics of a polyurethane (PU) mixture composite structure, quantitatively calculating its energy consumption and carbon emissions were analyzed in this study. Inclined shear tests were carried out on thirteen structures without interlaminar treatment, and high-temperature water bath accelerated loading tests were conducted on three composite structures; further, the interlaminar shear strength of the tire trace position after the accelerated loading test was tested to analyze the influence of both the high-temperature water bath environment and loading on the structure. In addition, based on the medium repair project of the Qingdao-Yinchuan expressway, the construction log of PU mixture pavement and asphalt pavement was investigated. Combined with the calculation parameters provided by the United Nations Intergovernmental Panel on Climate Change (IPCC), the consumption and carbon emissions of the two types of mixtures were calculated and compared quantitatively. The results showed that the shear strength between layers of asphalt mixtures, PU mixture and asphalt mixture was less than 2 MPa; however, the shear strength between PU mixture–cement-stabilized macadam and PU mixture–PU mixture was greater than 3 MPa. Therefore, it was recommended to spread a 0.4 L/m2 two-component PU adhesive layer as the interlayer treatment scheme for the structure of asphalt mixture-PU mixture and PU mixture-asphalt mixture; the high-temperature water area and accelerated loading had different effects on the interlaminar shear strength of the three structures. The PUM-16 mixture could effectively reduce energy consumption by 88.3 and 87.2%, carbon emissions by 81.1% and 79.1% in comparison to Stone Matrix asphalt with Nominal maximum particle size of 13.2 mm (SMA-13) and Stone Matrix asphalt with Nominal maximum particle size of 19.0 mm (SMA-20). Thus, the PU mixture was confirmed to be an environmentally friendly road pavement material.


  • Open Access

    Mechanism of Polyurethane Binder Curing Reaction and Evaluation of Polyurethane Mixture Properties

    by Min Sun, Yufeng Bi, Wei Zhuang, Sai Chen, Pinhui Zhao, Dezheng Pang, Wensheng Zhang

    This study focuses on analyzing the curing reaction mechanism of polyurethane (PU) binders and comprehensively evaluating the PU mixture’s properties. The former was investigated by conducting a Fourier transform infrared spectroscopy (FTIR) test on PU binders with different curing times. The volume change characteristics, construction operation time, and strength formation law were clarified through the splitting tensile test of PU mixtures under different environmental conditions. The optimal PU mixture stacking time and curing time under different environmental conditions were determined. The properties of the PU mixture and asphalt mixture were evaluated and compared through a rutting test, low-temperature bending test, freeze–thaw splitting test, and four-point bending fatigue test. The results show that the physical and chemical curing of the PU binder occurred within the first 24 h of curing, and the reaction speed gradually accelerated to form a polyurea structure 24 h later. It is recommended to stack the PU mixture for 4 h before compaction and to cure it for 2 days before opening under the conditions of 50% humidity and 15–40 °C surrounding temperature. The PU mixture shows better temperature stability and fatigue resistance than the asphalt mixture, and the splitting tensile strength of the PU mixture before and after the freeze–thaw splitting test is also higher. It is clear that the PU mixture is a green road building material with good performance.