YAYongheng Ai

Yongheng Ai

*This is an algorithmically generated author record based on publicly available information.

Yongheng Ai has a total of 14 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Two-Sheath Loop Short Circuit Defects Detection in High-Voltage Cable Systems Using Sheath Current Phasors

    by Weihua Yuan, Jing Tu, Yongheng Ai, Zhanran Xia, Ruoxin Song, Jianfeng He, Xinyun Gao, Minghong Jiang, Bin Yang, Bo Li, et al.

    The joint is the weak point of HV (high voltage) cable insulation systems; creep discharge between insulation layers of the cable joint, due to moisture intrusion, is one of the main defects leading to single-phase grounding. Carbonization on the insulation interface after creep discharge would lead to a short-circuit defect in the sheath loops and result in abnormal sheath current. In this study, a novel diagnostic criterion using the phasor difference of sheath currents at both ends of the same circuit is proposed. The coupling effect between the sheath and the conductor under defect conditions is considered, and the original lumped parameter model of the cable circuit is optimized. The cable parameters are further corrected using a genetic algorithm. The diagnostic criterion comprehensively accounts for the adverse effects of unequal cable segment lengths, load current fluctuations, grounding impedance, and phase voltage variations. When the phase angle fluctuation of the phasor difference is within 10° and the defect impedance is below 100 Ω, the defective joint can be accurately diagnosed by this method. The conclusion has been validated through PSCAD simulations, with a diagnostic accuracy above 97%. Even under 20 dB noise interference, the error increase remains within 2%.


  • Open Access

    A Communication Encryption-Based Distributed Cooperative Control for Distributed Generators in Microgrids under FDI Attacks

    by Han Fu, Wenpei Li, Long Qiu, Yongheng Ai, Zhixiong Liu

    To alleviate the hassle of false data injection (FDI) attacks on distributed generators (DGs) in microgrids, a communication encryption-based distributed cooperative control is proposed in this paper. Compared to the conventional distributed control strategies, the proposed control scheme is simpler with much less complex evaluation mechanism by upgrading the secondary control to a second-order control based on the finite-time control theory while combining an encryption strategy. The proposed algorithm provides constant injections to eliminate the impact of FDI attacks based on a robust communication system. The effectiveness and high efficiency of the proposed control scheme is validated in an IEEE 34 Node Test Feeder system with six DGs as a microgrid cyber-physical system (CPS) under different FDI attacks.