Haiyong Wan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Haiyong Wan has a total of 28 co-authors. Here are the top co-authors by number of shared publications:
- Li Ran
State Key Laboratory of Power Transmission Equipment Technology, School of Electrical Engineering, Chongqing University, Chongqing, China
3 shared publications - Nikolaos Iosifidis
School of Engineering, The University of Warwick, Coventry, U.K.
3 shared publications - Phillip Andrew Mawby
Warwick University
3 shared publications - Xu Zhang
School of Engineering, The University of Warwick, Coventry, U.K.
3 shared publications - Heaklig Ayala
School of Engineering, University of Warwick, Coventry, U.K.
2 shared publications - Jianying Li
State Key Laboratory of Electrical Insulation and Power Equipment, Xian Jiaotong University, Xian, China
2 shared publications
Latest Publications
- 19 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Electron Devices
- Vol. 73 (6) , 3308-3320
Correlations Between Body Diode Pulsed Overcurrent Safe Operating Area, Short Circuit, and Avalanche Ruggedness in SiC MOSFETs
Power MOSFETs are sometimes taken outside their safe operating area (SOA). This can be during pulsed overcurrents, avalanche conduction mode during unclamped inductive switching (UIS) or short-circuit events. These conditions present different stresses to the device. In pulsed overcurrent conditions, the device is subject to overcurrents at low voltage; in UIS, the device is subject to overvoltage at low currents; and in short circuits, the device is subject to both. The ability of the MOSFET to withstand these conditions is a key robustness metric. How robustness under these three electrothermal shock events correlates with one another is yet to be investigated systematically. The objective of this article is to correlate these metrics in SiC MOSFETs by characterizing planar, asymmetric trench, and double-trench device structures. The critical energies to failure have been determined for all devices under the three undesired operating conditions, and correlations have been made. The maximum junction temperatures have been inferred by temperature-sensitive electrical parameters and confirmed with electrothermal simulations. The analysis in this article demonstrates that the critical avalanche and surge energies to failure are directly correlated, and they increase with stress duration. Furthermore, a tradeoff between short-circuit robustness and surge/avalanche robustness is observed based on device-specific on-state resistance.
- 19 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Electron Devices
- Vol. 73 (6) , 3308-3320
Correlations Between Body Diode Pulsed Overcurrent Safe Operating Area, Short Circuit, and Avalanche Ruggedness in SiC MOSFETs
Power MOSFETs are sometimes taken outside their safe operating area (SOA). This can be during pulsed overcurrents, avalanche conduction mode during unclamped inductive switching (UIS) or short-circuit events. These conditions present different stresses to the device. In pulsed overcurrent conditions, the device is subject to overcurrents at low voltage; in UIS, the device is subject to overvoltage at low currents; and in short circuits, the device is subject to both. The ability of the MOSFET to withstand these conditions is a key robustness metric. How robustness under these three electrothermal shock events correlates with one another is yet to be investigated systematically. The objective of this article is to correlate these metrics in SiC MOSFETs by characterizing planar, asymmetric trench, and double-trench device structures. The critical energies to failure have been determined for all devices under the three undesired operating conditions, and correlations have been made. The maximum junction temperatures have been inferred by temperature-sensitive electrical parameters and confirmed with electrothermal simulations. The analysis in this article demonstrates that the critical avalanche and surge energies to failure are directly correlated, and they increase with stress duration. Furthermore, a tradeoff between short-circuit robustness and surge/avalanche robustness is observed based on device-specific on-state resistance.
- 26 June 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 40 (11) , 16979-16994
Stress Management of Wind Turbine Components Using a Nano-Enhanced Phase Change Material Integrated Power Module
Offshore wind turbine components endure high mechanical and thermal stress due to fluctuating wind conditions and harsh marine environments, but lack coordinated stress management due to the low thermal inertia of the power electronic system. Frequent and large pitch movements further aggravate component stress. This article introduces a power module packaging method that integrates nano-enhanced phase change materials (PCMs) to provide short-term overload capability. By mixing PCMs with carbon nanotubes, the thermal resistance per insulated gate bipolar transistor (IGBT) of the nano-enhanced PCM module is reduced by 34% and 14% compared to the conventional module and PCM module respectively due to the increased thermal conductivity of PCMs. Finite element analysis and experimental results demonstrate the superior thermal performance of the nano-enhanced PCM module over traditional modules. Based on this improved functionality, a stress management strategy is proposed to mitigate mechanical stress on the pitch system by increasing the rated wind speed and temporarily overloading the turbine powertrain system. Statistical analysis based on real wind speed profiles validates the strategy’s effectiveness, showing a reduction in the number of pitch angle cycles by up to 86% .
- 26 June 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 40 (11) , 16979-16994
Stress Management of Wind Turbine Components Using a Nano-Enhanced Phase Change Material Integrated Power Module
Offshore wind turbine components endure high mechanical and thermal stress due to fluctuating wind conditions and harsh marine environments, but lack coordinated stress management due to the low thermal inertia of the power electronic system. Frequent and large pitch movements further aggravate component stress. This article introduces a power module packaging method that integrates nano-enhanced phase change materials (PCMs) to provide short-term overload capability. By mixing PCMs with carbon nanotubes, the thermal resistance per insulated gate bipolar transistor (IGBT) of the nano-enhanced PCM module is reduced by 34% and 14% compared to the conventional module and PCM module respectively due to the increased thermal conductivity of PCMs. Finite element analysis and experimental results demonstrate the superior thermal performance of the nano-enhanced PCM module over traditional modules. Based on this improved functionality, a stress management strategy is proposed to mitigate mechanical stress on the pitch system by increasing the rated wind speed and temporarily overloading the turbine powertrain system. Statistical analysis based on real wind speed profiles validates the strategy’s effectiveness, showing a reduction in the number of pitch angle cycles by up to 86% .
- 9 June 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 40 (10) , 15381-15398
Single-Phase and Evaporating Two-Phase Flow Microchannel Cooling of Power Modules for Temporary Overcurrent Operation
Evaporating two-phase flows are usually avoided in cooling applications due to the potential inception of flow instabilities, which result in worse cooling performance. However, the substantial latent heat of liquid evaporation presents a compelling source in power electronics cooling when temporary overcurrent is needed. In this study, we utilise water evaporation to enhance the cooling performance under temporary module overcurrent conditions, while the water remains in its liquid phase during nominal operation. The proof-of-concept is demonstrated for a Si IGBT/diode half-bridge module cooled with a microchannel array integrated below the direct bonded copper ceramic. The microchannel cooling solution is evaluated in terms of reduction in the junction-to-case thermal resistance and of an increase in the temporary overcurrent capability. The thermal resistance is extracted for different flow rates using Simcenter Micred Power Tester. Infrared and visible spectrum cameras are used to simultaneously record the junction temperature and the evaporating flow in the microchannel array. Flow regimes with parts of individual channels occupied by the flow of vapor have been observed in the overcurrent duration, resulting in heat transported downstream from the chip location, where liquid evaporates, to the outlet of the manifold. Results indicate that evaporation enhances the cooling performance for the tested conditions, with no signs of boiling crisis in the microchannel flow.
- 9 June 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 40 (10) , 15381-15398
Single-Phase and Evaporating Two-Phase Flow Microchannel Cooling of Power Modules for Temporary Overcurrent Operation
Evaporating two-phase flows are usually avoided in cooling applications due to the potential inception of flow instabilities, which result in worse cooling performance. However, the substantial latent heat of liquid evaporation presents a compelling source in power electronics cooling when temporary overcurrent is needed. In this study, we utilise water evaporation to enhance the cooling performance under temporary module overcurrent conditions, while the water remains in its liquid phase during nominal operation. The proof-of-concept is demonstrated for a Si IGBT/diode half-bridge module cooled with a microchannel array integrated below the direct bonded copper ceramic. The microchannel cooling solution is evaluated in terms of reduction in the junction-to-case thermal resistance and of an increase in the temporary overcurrent capability. The thermal resistance is extracted for different flow rates using Simcenter Micred Power Tester. Infrared and visible spectrum cameras are used to simultaneously record the junction temperature and the evaporating flow in the microchannel array. Flow regimes with parts of individual channels occupied by the flow of vapor have been observed in the overcurrent duration, resulting in heat transported downstream from the chip location, where liquid evaporates, to the outlet of the manifold. Results indicate that evaporation enhances the cooling performance for the tested conditions, with no signs of boiling crisis in the microchannel flow.
- 23 April 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 13 (4) , 4488-4503
A Comparative Study of Thermal Management Strategies for Overcurrent in Aircraft Power Electronics Applications
The increasing power density in More Electric Aircraft (MEA) systems poses significant thermal challenges for power electronics, especially during overcurrent scenarios and fault conditions throughout flight cycles. Efficient thermal management is therefore essential. This paper presents a comparative study of three thermal management strategies— liquid metal phase change material (PCM), thermoelectric cooling (TEC), and heat pipes—evaluated in terms of time-scale response and thermal performance under overcurrent conditions. Results indicate that liquid metal PCM responds in the seconds range, while TEC and heat pipes provide faster responses in the milliseconds range. All three strategies demonstrated significant improvements over conventional power module designs, achieving thermal resistance reductions of 45%, 35%, and 21% for heat pipe, TEC, and PCM, respectively. The heat pipe configuration exhibited the lowest thermal resistance and the most substantial reduction in junction temperature during overcurrent conditions. The overcurrent cycling test demonstrates that all three strategies effectively reduce both the mean junction temperature and junction temperature swing, resulting in an increased number of cycles to failure.
- 23 April 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 13 (4) , 4488-4503
A Comparative Study of Thermal Management Strategies for Overcurrent in Aircraft Power Electronics Applications
The increasing power density in More Electric Aircraft (MEA) systems poses significant thermal challenges for power electronics, especially during overcurrent scenarios and fault conditions throughout flight cycles. Efficient thermal management is therefore essential. This paper presents a comparative study of three thermal management strategies— liquid metal phase change material (PCM), thermoelectric cooling (TEC), and heat pipes—evaluated in terms of time-scale response and thermal performance under overcurrent conditions. Results indicate that liquid metal PCM responds in the seconds range, while TEC and heat pipes provide faster responses in the milliseconds range. All three strategies demonstrated significant improvements over conventional power module designs, achieving thermal resistance reductions of 45%, 35%, and 21% for heat pipe, TEC, and PCM, respectively. The heat pipe configuration exhibited the lowest thermal resistance and the most substantial reduction in junction temperature during overcurrent conditions. The overcurrent cycling test demonstrates that all three strategies effectively reduce both the mean junction temperature and junction temperature swing, resulting in an increased number of cycles to failure.