Ping Li
Research Subjects
Ping Li has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Xiaomei Guo
Key Laboratory of Key Technologies for Mechanical Industry Hydroelectric Power Generation Pump Turbine, Zhejiang Key Laboratory of Pumps and Turbines, Zhejiang University of Water Resource and Electric Power, Hangzhou 310018, China
3 shared publications - Aminjon Gulakhmadov
Institute of Water Problems, Hydropower and Ecology of the National Academy of Sciences of Tajikistan Dushanbe Tajikistan
2 shared publications - Saidabdullo Qurbonalizoda
National Academy of Sciences of Tajikistan Center of Innovative Development of Science and New Technologies, Dushanbe 734002, Tajikistan
2 shared publications - Sunwuji Wang
School of Mechanical and Engineering, Ningxia University, Yinchuan 750021, China
2 shared publications - Zuchao Zhu
Key Laboratory of Fluid Transmission Technology of Zhejiang Province, Zhejiang Sci-Tech University 1 , Hangzhou 310018
2 shared publications - Aleksandr N. Grigorchik
Joint Institute of Mechanical Engineering, National Academy of Sciences of Belarus, 220072 Minsk, Belarus
1 shared publication
Latest Publications
- Open Access
Development Status and Prospects of Centrifugal Pump Cavitation: A Bibliometric Analysis Using CiteSpace
This study employs CiteSpace 6.3 R1 software to conduct a quantitative analysis of 645 cavitation-related centrifugal pump publications from the Web of Science Core Collection database (2007–2025) using bibliometric methods. The analysis encompasses publication volume statistics, keyword co-occurrence analysis, and keyword clustering. The results indicate that research on centrifugal pump cavitation is currently in a phase of rapid development. The annual number of publications related to centrifugal pump cavitation shows an overall fluctuating upward trend, with Jiangsu University emerging as the leading research institution. The research hotspots include fault diagnosis, impeller design, numerical simulation, and validation, forming four major developmental pathways. Research on cavitation in centrifugal pumps has gradually shifted its focus from numerical simulation to practical engineering issues such as pressure pulsation and cavitation, with hot topics evolving at an accelerated pace. Future efforts must address challenges like cavitation monitoring and high-precision simulation to comprehensively enhance the anti-cavitation performance and operational reliability of centrifugal pumps.
Open AccessDevelopment Status and Prospects of Centrifugal Pump Cavitation: A Bibliometric Analysis Using CiteSpace
This study employs CiteSpace 6.3 R1 software to conduct a quantitative analysis of 645 cavitation-related centrifugal pump publications from the Web of Science Core Collection database (2007–2025) using bibliometric methods. The analysis encompasses publication volume statistics, keyword co-occurrence analysis, and keyword clustering. The results indicate that research on centrifugal pump cavitation is currently in a phase of rapid development. The annual number of publications related to centrifugal pump cavitation shows an overall fluctuating upward trend, with Jiangsu University emerging as the leading research institution. The research hotspots include fault diagnosis, impeller design, numerical simulation, and validation, forming four major developmental pathways. Research on cavitation in centrifugal pumps has gradually shifted its focus from numerical simulation to practical engineering issues such as pressure pulsation and cavitation, with hot topics evolving at an accelerated pace. Future efforts must address challenges like cavitation monitoring and high-precision simulation to comprehensively enhance the anti-cavitation performance and operational reliability of centrifugal pumps.
- Open Access
Impact of Inducer Tip Clearance on Cryopump Performance
Inducers play a critical role in pump operation by providing a preliminary pressure boost to suppress cavitation. The size of the tip clearance directly influences a pump’s operational efficiency. To investigate the impact of tip clearance on a pump’s hydraulic performance and its behavior under cavitation conditions, this study combines experimental and numerical simulation approaches. Numerical computations of the full flow field, including the inducer and a two-stage impeller, were performed for five liquefied natural gas (LNG) cryogenic inducers with different tip clearances. The accuracy of the numerical simulation results was validated by comparing them with the experimentally obtained hydraulic performance curves. The results yield cavitation performance curves, pressure distributions at incipient cavitation, vapor volume fraction contours, and leakage flow streamlines for various tip clearances. The impact of tip clearance on the overall hydraulic performance and cavitation behavior of the LNG inducer was systematically examined, with particular attention given to the microscopic evolution of the Tip Leakage Vortex (TLV) during the initial stages of cavitation. The experimental results indicate that for every 0.2 mm increase in the inducer tip clearance, the pump head decreases by approximately 1 m, the efficiency drops by about 0.2%, and the tip leakage flow rate increases by approximately 5 m3/h. Furthermore, under cavitation conditions, the cavitation area expands as the tip clearance increases. A critical clearance value, δ, exists within the range of 0.4 mm to 0.6 mm, which governs the development pattern of the TLV. When the clearance is smaller than δ, the TLV forms more rapidly, and cavitation development is significantly more sensitive to increases in tip clearance. Conversely, when the clearance exceeds δ, the formation of the TLV is delayed, and cavitation progression becomes less responsive to further increases in tip clearance.
Open AccessImpact of Inducer Tip Clearance on Cryopump Performance
Inducers play a critical role in pump operation by providing a preliminary pressure boost to suppress cavitation. The size of the tip clearance directly influences a pump’s operational efficiency. To investigate the impact of tip clearance on a pump’s hydraulic performance and its behavior under cavitation conditions, this study combines experimental and numerical simulation approaches. Numerical computations of the full flow field, including the inducer and a two-stage impeller, were performed for five liquefied natural gas (LNG) cryogenic inducers with different tip clearances. The accuracy of the numerical simulation results was validated by comparing them with the experimentally obtained hydraulic performance curves. The results yield cavitation performance curves, pressure distributions at incipient cavitation, vapor volume fraction contours, and leakage flow streamlines for various tip clearances. The impact of tip clearance on the overall hydraulic performance and cavitation behavior of the LNG inducer was systematically examined, with particular attention given to the microscopic evolution of the Tip Leakage Vortex (TLV) during the initial stages of cavitation. The experimental results indicate that for every 0.2 mm increase in the inducer tip clearance, the pump head decreases by approximately 1 m, the efficiency drops by about 0.2%, and the tip leakage flow rate increases by approximately 5 m3/h. Furthermore, under cavitation conditions, the cavitation area expands as the tip clearance increases. A critical clearance value, δ, exists within the range of 0.4 mm to 0.6 mm, which governs the development pattern of the TLV. When the clearance is smaller than δ, the TLV forms more rapidly, and cavitation development is significantly more sensitive to increases in tip clearance. Conversely, when the clearance exceeds δ, the formation of the TLV is delayed, and cavitation progression becomes less responsive to further increases in tip clearance.
- Open Access
- 26 November 2025
- Published by MDPI AG in Preprints.org
Impact of Inducer Tip Clearance on Cryopump Performance
To investigate the influence of different tip clearances on the hydraulic performance and cavitation characteristics of a cryogenic inducer, this study builds upon previous research by employing the SST k-ω turbulence model and modifying the empirical coefficients for evaporation and condensation in the Zwart cavitation model. Numerical simulations of the full flow field within an LNG cryogenic inducer were conducted. The results yielded cavitation performance curves, pressure distributions at incipient cavitation, vapor volume fraction contours, and leakage flow streamlines for various tip clearances. The impact of tip clearance on the overall hydraulic performance and cavitation behavior of the LNG inducer was systematically examined, with particular attention given to the microscopic evolution of the Tip Leakage Vortex (TLV) during the initial stages of cavitation. Experimental findings indicate that as the tip clearance increases, the tip leakage flow intensifies, leading to greater energy losses within the inducer and a consequent slight reduction in pump head and efficiency. A critical clearance value, δ, exists within the range of 0.4 mm to 0.6 mm, which governs the development pattern of the TLV. When the clearance is smaller than δ, the TLV forms more rapidly, and cavitation development is significantly more sensitive to increases in tip clearance. Conversely, when the clearance exceeds δ, the formation of the TLV is delayed, and cavitation progression becomes less responsive to further increases in tip clearance.
- 26 November 2025
- Published by MDPI AG in Preprints.org
Open AccessImpact of Inducer Tip Clearance on Cryopump Performance
To investigate the influence of different tip clearances on the hydraulic performance and cavitation characteristics of a cryogenic inducer, this study builds upon previous research by employing the SST k-ω turbulence model and modifying the empirical coefficients for evaporation and condensation in the Zwart cavitation model. Numerical simulations of the full flow field within an LNG cryogenic inducer were conducted. The results yielded cavitation performance curves, pressure distributions at incipient cavitation, vapor volume fraction contours, and leakage flow streamlines for various tip clearances. The impact of tip clearance on the overall hydraulic performance and cavitation behavior of the LNG inducer was systematically examined, with particular attention given to the microscopic evolution of the Tip Leakage Vortex (TLV) during the initial stages of cavitation. Experimental findings indicate that as the tip clearance increases, the tip leakage flow intensifies, leading to greater energy losses within the inducer and a consequent slight reduction in pump head and efficiency. A critical clearance value, δ, exists within the range of 0.4 mm to 0.6 mm, which governs the development pattern of the TLV. When the clearance is smaller than δ, the TLV forms more rapidly, and cavitation development is significantly more sensitive to increases in tip clearance. Conversely, when the clearance exceeds δ, the formation of the TLV is delayed, and cavitation progression becomes less responsive to further increases in tip clearance.