Zamir Aimaduddin Zulkefli
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Zamir Aimaduddin Zulkefli has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- Hasril Hasini
Department of Mechanical Engineering, College of Engineering, Putrajaya Campus, Universiti Tenaga Nasional, Jalan IKRAM-UNITEN, Kajang 43000, Malaysia
2 shared publications - Manmit Singh Jasbeer Singh
Department of Mechanical and Manufacturing Engineering, Universiti Putra Malaysia, 43400 UPM, Serdang, Selangor, Malaysia
2 shared publications - Nawal Aswan Abdul Jalil
Department of Mechanical and Manufacturing Engineering, Universiti Putra Malaysia, 43400 UPM, Serdang, Selangor, Malaysia
2 shared publications - Sharafiz Abdul Rahim
Universiti Putra Malaysia
2 shared publications - Abdul Aziz Nuraini
Department of Mechanical and Manufacturing Engineering, Faculty of Engineering, Universiti Putra Malaysia, 43400 Serdang, Selangor, Malaysia
1 shared publication Abdul Hakim Abdullah
Universiti Teknologi MARA
1 shared publication
Latest Publications
- Open Access
- 31 March 2023
- Published by Universiti Putra Malaysia in Pertanika Journal of Science and Technology
- Vol. 31 (3) , 1453-1474
Heat Rate Deviation Analysis of a Coal-Fired Power Plant (CFPP) with the Influence of Applicable Coal Prices (ACP)
Pertanika Journal information and guidelines
- 31 March 2023
- Published by Universiti Putra Malaysia in Pertanika Journal of Science and Technology
- Vol. 31 (3) , 1453-1474
Open AccessHeat Rate Deviation Analysis of a Coal-Fired Power Plant (CFPP) with the Influence of Applicable Coal Prices (ACP)
Pertanika Journal information and guidelines
- Open Access
- 3 March 2022
- Published by Universiti Putra Malaysia in Pertanika Journal of Science and Technology
- Vol. 30 (2) , 1003-1018
Thermo-Economic Analysis of a Coal-Fired Power Plant (CFPP) Using Turbine Cycle Heat Rate and Plant Net Heat Rates at Various Operating Loads
Evaluating Coal-Fired Power Plant (CFPP) performance is a complex process involving the determination of the turbine cycle Heat Rate (TCHR). This study focuses on determining the TCHR by developing a mathematical model. The model, which incorporates economic analysis of the plant, is developed using energy and mass balance relationships of the turbine cycle, validated using plant commissioning data from a 700MWn CFPP located in Perak, Malaysia. Actual plant data from a 700MWn CFPP is utilized to improve the accuracy and increase the confidence of the results of this study. It was found that at the nominal operating load of 729MWg, there is a Heat Rate (HR) deviation of -1,135 kJ/kWh, leading to daily losses of RM240,447 or USD 60,112. Furthermore, it is possible to utilize the developed model at lower loads as the plant is now being used to operate on “cyclic” loads. The daily losses at a lower load of 431MWg are RM125,767 or USD31,442. Thus, the model is able to compare the plant HR at various loads against commissioning data, and economic analysis is able to be carried out effectively. Valuable information for plant operations and performance engineers could be obtained using this model to determine plant HR.
- 3 March 2022
- Published by Universiti Putra Malaysia in Pertanika Journal of Science and Technology
- Vol. 30 (2) , 1003-1018
Open AccessThermo-Economic Analysis of a Coal-Fired Power Plant (CFPP) Using Turbine Cycle Heat Rate and Plant Net Heat Rates at Various Operating Loads
Evaluating Coal-Fired Power Plant (CFPP) performance is a complex process involving the determination of the turbine cycle Heat Rate (TCHR). This study focuses on determining the TCHR by developing a mathematical model. The model, which incorporates economic analysis of the plant, is developed using energy and mass balance relationships of the turbine cycle, validated using plant commissioning data from a 700MWn CFPP located in Perak, Malaysia. Actual plant data from a 700MWn CFPP is utilized to improve the accuracy and increase the confidence of the results of this study. It was found that at the nominal operating load of 729MWg, there is a Heat Rate (HR) deviation of -1,135 kJ/kWh, leading to daily losses of RM240,447 or USD 60,112. Furthermore, it is possible to utilize the developed model at lower loads as the plant is now being used to operate on “cyclic” loads. The daily losses at a lower load of 431MWg are RM125,767 or USD31,442. Thus, the model is able to compare the plant HR at various loads against commissioning data, and economic analysis is able to be carried out effectively. Valuable information for plant operations and performance engineers could be obtained using this model to determine plant HR.
- 23 June 2016
- Published by Penerbit UTM Press in Jurnal Teknologi (Sciences & Engineering)
- Vol. 78 (6-10)
PREDICTING THE TRANSMISSIBILITY OF A GLOVE MATERIAL TO THE PALM USING A SIMPLE LUMPED PARAMETER MODEL OF THE HAND AND THE GLOVE
Assessing a glove for its ability to reduce vibration transmitted to the hand can be improved if the transmissibility of the glove to the hand can be predicted. This study proposes a simple lumped parameter model of the hand and the glove for predicting the transmissibility of a glove to the hand. The model of the hand consists of three main body segments: the palm, the fingers, and the palm tissues, connected via translational and rotational springs and dampers. The glove material was represented by translational spring and damper. The results showed that the glove transmissibility predicted using the model overestimated the glove transmissibility measured experimentally at frequencies greater than 62 Hz, implying that a simple three degree-of-freedom model of the hand and the glove may not be able to provide a reasonable prediction of glove transmissibility.
- 23 June 2016
- Published by Penerbit UTM Press in Jurnal Teknologi (Sciences & Engineering)
- Vol. 78 (6-10)
PREDICTING THE TRANSMISSIBILITY OF A GLOVE MATERIAL TO THE PALM USING A SIMPLE LUMPED PARAMETER MODEL OF THE HAND AND THE GLOVE
Assessing a glove for its ability to reduce vibration transmitted to the hand can be improved if the transmissibility of the glove to the hand can be predicted. This study proposes a simple lumped parameter model of the hand and the glove for predicting the transmissibility of a glove to the hand. The model of the hand consists of three main body segments: the palm, the fingers, and the palm tissues, connected via translational and rotational springs and dampers. The glove material was represented by translational spring and damper. The results showed that the glove transmissibility predicted using the model overestimated the glove transmissibility measured experimentally at frequencies greater than 62 Hz, implying that a simple three degree-of-freedom model of the hand and the glove may not be able to provide a reasonable prediction of glove transmissibility.
- 1 June 2015
- Published by ASME International in Journal of Vibration and Acoustics
- Vol. 137 (3) , 034502
Mitigation of Gear Mesh-Frequency Noise Using a Hydrostatic Bearing
A proposed solution to reducing gear mesh-frequency vibrations in a gear-set involves the utilization of hydrostatic bearings placed in series, load wise, with the main support bearing. The hydrostatic bearings are expected to utilize its low pass filtering effect of the vibrational energies to prevent its transmission from the shaft to the gear housing where it would be emitted as noise. The present investigation examines the frequency response of a single-recess circular hydrostatic bearing under applied sinusoidal loads. The results show that as the driving frequency increases, the filtering effect of the hydrostatic bearing increases. The exhibited behavior is similar to the behavior of a low pass filter: negligible filtering effect at low frequencies, the filtering effect increasing from 0% to 90% over the midfrequencies range and the filtering effect remaining at the maximum value as the frequencies of the applied signals continue to increase. This observed behavior is expected to play a central role in the proposed gear mesh-frequency vibration mitigation system.
- 1 June 2015
- Published by ASME International in Journal of Vibration and Acoustics
- Vol. 137 (3) , 034502
Mitigation of Gear Mesh-Frequency Noise Using a Hydrostatic Bearing
A proposed solution to reducing gear mesh-frequency vibrations in a gear-set involves the utilization of hydrostatic bearings placed in series, load wise, with the main support bearing. The hydrostatic bearings are expected to utilize its low pass filtering effect of the vibrational energies to prevent its transmission from the shaft to the gear housing where it would be emitted as noise. The present investigation examines the frequency response of a single-recess circular hydrostatic bearing under applied sinusoidal loads. The results show that as the driving frequency increases, the filtering effect of the hydrostatic bearing increases. The exhibited behavior is similar to the behavior of a low pass filter: negligible filtering effect at low frequencies, the filtering effect increasing from 0% to 90% over the midfrequencies range and the filtering effect remaining at the maximum value as the frequencies of the applied signals continue to increase. This observed behavior is expected to play a central role in the proposed gear mesh-frequency vibration mitigation system.
- 6 June 2014
- Published by Trans Tech Publications, Ltd. in Applied Mechanics and Materials
- Vol. 564, 176-181
Identification of Corrosion on a Hollow Tube Using Vibration
Vibration based technique have so far been focused on the identification of structural damage. However, not many studies have been conducted on the corrosion identification on pipes. The objective of this paper is to identify corrosion on pipes from vibration measurements. A hollow pipe, 500 mm in length with 63.5 mm in diameter was subjected to impact loading using an impact hammer to identify the natural frequency of the tube in two conditions i) without any corrosion and ii) with an induced localized 40 mm by 40 mm corrosion at the middle of the pipe. The shift of natural frequencies of the structures under free boundary conditions was examined for each node of excitation. The results showed that there is a shift in natural frequency of the pipe, between 3 and 4 Hz near to the corrosion area. It can suggested that that the impact vibration is capable of identifying of localized corrosion on a hollow tube.
- 6 June 2014
- Published by Trans Tech Publications, Ltd. in Applied Mechanics and Materials
- Vol. 564, 176-181
Identification of Corrosion on a Hollow Tube Using Vibration
Vibration based technique have so far been focused on the identification of structural damage. However, not many studies have been conducted on the corrosion identification on pipes. The objective of this paper is to identify corrosion on pipes from vibration measurements. A hollow pipe, 500 mm in length with 63.5 mm in diameter was subjected to impact loading using an impact hammer to identify the natural frequency of the tube in two conditions i) without any corrosion and ii) with an induced localized 40 mm by 40 mm corrosion at the middle of the pipe. The shift of natural frequencies of the structures under free boundary conditions was examined for each node of excitation. The results showed that there is a shift in natural frequency of the pipe, between 3 and 4 Hz near to the corrosion area. It can suggested that that the impact vibration is capable of identifying of localized corrosion on a hollow tube.
- 6 June 2014
- Published by Trans Tech Publications, Ltd. in Applied Mechanics and Materials
- Vol. 564, 129-134
A Study of the Acoustics and Speech Intelligibility Quality of Mosques in Malaysia
This study presents the assessment of the quality of speech intelligibility of two Malaysian mosques and the results are used to develop a set of general acoustical guidelines to be used in the design of a mosque. Two mosques were selected for the research: Masjid UPM and the Masjid Jamek. The objective of the research is to enable the comparison of the acoustics and speech intelligibility between the mosques as function of the size, volume, occupancy and other parameters of the main prayer hall on the acoustic and speech intelligibility of the respective mosques. The reverberation time (RT60), speech level (SL), background noise (BN), signal-to-noise ratio (S/N ratio) were determined and are used to develop the speech transmission index (STI) and rapid transmission index (RASTI) prediction models for both mosques. It was observed from the results that the RT60, STI and RASTI values shows better performance over number of occupancy for both mosques. Furthermore, the BN and SL results were visualized using the spatial distribution patterns (SDP) of the main hall. The results of the analysis show that the overall acoustic and speech quality of Masjid Jamek is better when compared to the overall acoustic and speech quality of Masjid UPM. These results are then used to develop a set of design recommendations to ensure adequate speech intelligibility quality a mosque.
- 6 June 2014
- Published by Trans Tech Publications, Ltd. in Applied Mechanics and Materials
- Vol. 564, 129-134
A Study of the Acoustics and Speech Intelligibility Quality of Mosques in Malaysia
This study presents the assessment of the quality of speech intelligibility of two Malaysian mosques and the results are used to develop a set of general acoustical guidelines to be used in the design of a mosque. Two mosques were selected for the research: Masjid UPM and the Masjid Jamek. The objective of the research is to enable the comparison of the acoustics and speech intelligibility between the mosques as function of the size, volume, occupancy and other parameters of the main prayer hall on the acoustic and speech intelligibility of the respective mosques. The reverberation time (RT60), speech level (SL), background noise (BN), signal-to-noise ratio (S/N ratio) were determined and are used to develop the speech transmission index (STI) and rapid transmission index (RASTI) prediction models for both mosques. It was observed from the results that the RT60, STI and RASTI values shows better performance over number of occupancy for both mosques. Furthermore, the BN and SL results were visualized using the spatial distribution patterns (SDP) of the main hall. The results of the analysis show that the overall acoustic and speech quality of Masjid Jamek is better when compared to the overall acoustic and speech quality of Masjid UPM. These results are then used to develop a set of design recommendations to ensure adequate speech intelligibility quality a mosque.
- 1 April 2014
- Published by SAE International in SAE International Journal of Advances and Current Practices in Mobility
- Vol. 1
Experimental Investigation of the Low Pass Filtering Effect of a Hydrostatic Bearing
Gears are used in numerous applications where mechanical power needs to be transmitted as in the powertrain of cars, buses and other vehicles. These gears can potentially be a significant source of high-frequency vibration and radiated noise in a vehicle, which can be both harmful and objectionable to any listeners in the vicinity. A proposed approach to addressing the gear mesh-frequency vibrations is to utilize the low pass filtering effect of a hydrostatic bearing in a gear mesh-frequency noise mitigation system. This paper describes an experimental investigation of the low pass filtering effect of a hydrostatic bearing using an experimental setup involving a widely available materials testing machine. By using the materials testing machine, appropriately sized hydrostatic bearing and externally pressurized fluid supply system, empirical data was collected that allowed the frequency response of the hydrostatic bearing to be determined. The frequency response of the hydrostatic bearing clearly shows a low pass filtering effect on the applied dynamic loads. Furthermore, changes to various system parameters had no effect on the frequency responses except at high driving frequency values. The observed low pass filtering effect of the hydrostatic bearing is potentially of great significance in any proposed gear mesh-frequency noise mitigation system since it prevents the mesh-frequency vibratory energy from being transmitted. Additionally, the experimental setup used provides a relatively simple setup for further studies on the dynamic behavior of the hydrostatic bearing.
- 1 April 2014
- Published by SAE International in SAE International Journal of Advances and Current Practices in Mobility
- Vol. 1
Experimental Investigation of the Low Pass Filtering Effect of a Hydrostatic Bearing
Gears are used in numerous applications where mechanical power needs to be transmitted as in the powertrain of cars, buses and other vehicles. These gears can potentially be a significant source of high-frequency vibration and radiated noise in a vehicle, which can be both harmful and objectionable to any listeners in the vicinity. A proposed approach to addressing the gear mesh-frequency vibrations is to utilize the low pass filtering effect of a hydrostatic bearing in a gear mesh-frequency noise mitigation system. This paper describes an experimental investigation of the low pass filtering effect of a hydrostatic bearing using an experimental setup involving a widely available materials testing machine. By using the materials testing machine, appropriately sized hydrostatic bearing and externally pressurized fluid supply system, empirical data was collected that allowed the frequency response of the hydrostatic bearing to be determined. The frequency response of the hydrostatic bearing clearly shows a low pass filtering effect on the applied dynamic loads. Furthermore, changes to various system parameters had no effect on the frequency responses except at high driving frequency values. The observed low pass filtering effect of the hydrostatic bearing is potentially of great significance in any proposed gear mesh-frequency noise mitigation system since it prevents the mesh-frequency vibratory energy from being transmitted. Additionally, the experimental setup used provides a relatively simple setup for further studies on the dynamic behavior of the hydrostatic bearing.
- Open Access
- 24 January 2010
- Published by Defence Scientific Information and Documentation Centre in Defence Science Journal
- Vol. 60 (1) , 112-118
Strength Investigation of Thick Welded T-Joint using Finite Element Modelling
Strength Investigation of Thick Welded T-Joint using Finite Element Modelling
- 24 January 2010
- Published by Defence Scientific Information and Documentation Centre in Defence Science Journal
- Vol. 60 (1) , 112-118
Open AccessStrength Investigation of Thick Welded T-Joint using Finite Element Modelling
Strength Investigation of Thick Welded T-Joint using Finite Element Modelling