CAChris Adams

Chris Adams

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Chris Adams has a total of 25 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Implementation of a Skull-Conformal Phased Array for Transcranial Focused Ultrasound Therapy

    by Chris Adams, Ryan M. Jones, Steven D. Yang, Wai Meng Kan, Kogee Leung, Yuheng Zhou, Kang Uk Lee, Yuexi Huang, Kullervo Hynynen

    Objective: To implement a skull-conformal phased array for ultrasound-guided transcranial focused ultrasound therapy with improved patient comfort. Methods: Using patient-specific computed tomography and MRI neuroimaging data, tightly-conforming helmet scaffolds were designed computationally. The helmet scaffolds were designed to hold reusable transducer modules at near-normal incidence in an optimal configuration for the treatment location(s) of interest. Numerical simulations of trans-skull ultrasound propagation were performed to evaluate different conformal array designs and to compare with hemispherical arrays similar to those employed clinically. A 4096-element phased array was constructed by 3D printing a helmet scaffold optimised for an ex vivo human skullcap, and its performance was evaluated via benchtop and in vivo experiments. Results: Acoustic field measurements confirmed the system's ability to focus through human skull bone using simulation-based transcranial aberration corrections. Preliminary in vivo testing demonstrated safe trans-human skull blood-brain barrier (BBB) opening in rodents. Conclusion: Patient-specific conformal ultrasound phased arrays appear to be a feasible and safe approach for conducting transcranial BBB opening procedures. Significance: Skull-conformal phased arrays stand to improve patient comfort and have the potential to accelerate the adoption of transcranial FUS therapy by improving access to the technology.


  • HIFU Power Monitoring Using Combined Instantaneous Current and Voltage Measurement

    by Chris Adams, James R. McLaughlan, Thomas M. Carpenter, Steven Freear

    During high-intensity focused ultrasound (HIFU) therapy, it is important that the electrical power delivered to the transducer is monitored to avoid underexposure or overexposure, ensure patient safety, and to protect the transducer itself. Due to ease of measurement, the transducer's potential difference may be as an indicator of power delivery. However, even when a transducer's complex impedance is well characterized at small amplitudes and matching networks are used, voltage-only (VO) monitoring cannot account for the presence of drive waveform distortion, changes to the acoustic path, or damage to the transducer. In this study, combined current and voltage (CCV) is proposed as a magnetic resonance imaging (MRI)-compatible, miniature alternative to bidirectional power couplers, which is compatible with switched amplifiers. For CCV power measurement, current probe data were multiplied by the voltage waveform and integrated in the frequency domain. Transducer efficiency was taken into account to predict acoustic power. The technique was validated with a radiation force balance (RFB). When using a typical HIFU transducer and amplifier, VO predictions and acoustic power had a maximum difference of 20%. However, under the same conditions, CCV only had a maximum difference of 5%. The technique was applied to several lesioning experiments and it was shown that when VO was used as a control between two amplifiers, there was up to a 38% difference in lesion area. This greatly reduced to a maximum of 5% once CCV was used instead. These results demonstrate that CCV can accurately predict real-time electrical power delivery, leading to safer HIFU treatments.


  • Open Access

    HIFU Drive System Miniaturization Using Harmonic Reduced Pulsewidth Modulation

    by Chris Adams, Thomas M. Carpenter, David Cowell, Steven Freear, James R. McLaughlan

    Switched excitation has the potential to improve on the cost, efficiency, and size of the linear amplifier circuitry currently used in high-intensity focused ultrasound (HIFU) systems. Existing switching schemes are impaired by high harmonic distortion or lack array apodisation capability, so require adjustable supplies and/or large power filters to be useful. A multilevel pulsewidth modulation (PWM) topology could address both of these issues but the switching-speed limitations of transistors mean that there are a limited number of pulses available in each waveform cycle. In this study, harmonic reduction PWM (HRPWM) is proposed as an algorithmic solution to the design of switched waveforms. Its appropriateness for HIFU was assessed by design of a high power five-level unfiltered amplifier and subsequent thermal-only lesioning of ex vivo chicken breast. Three switched waveforms of different electrical powers (16, 26, 35 W) were generated using the HRPWM algorithm. Lesion sizes were measured and compared with those made at the same electrical power using a linear amplifier and bi-level excitation. HRPWM produced symmetric, thermal-only lesions that were the same size as their linear amplifier equivalents (p > 0.05). At 16 W, bi-level excitation produced smaller lesions but at higher power levels large transients in the acoustic waveform nucleated undesired cavitation. These results demonstrate that HRPWM can minimize HIFU drive circuity size without the need for filters to remove harmonics or adjustable power supplies to achieve array apodisation.


  • Excitation and acquisition of cranial guided waves using a concave array transducer

    by Chris Adams, James McLaughlan, Luzhen Nie, Steven Freear

    Ultrasonic therapeutic transducers that consist of large numbers of unfocused, low power elements have begun to replace single high power elements. This allows the operator to use phased array techniques to change the focal position in the tissue during therapy. In transcranial therapy, this phased array configuration is essential to reduce local heating at the highly attenuating bone. Recently, Dual Mode Ultrasound Arrays (DMUAs) have been developed which leverage existing elements for imaging during therapy. DMUAs have the benefit of both the therapeutic and imaging systems being co-registered. Unfortunately, the highly reflective nature of bone means that DMUAs have not been applied to skull imaging. However the recent near-field observation of lamb waves in cranial bone opens the possibility for DMUAs to be applied to a guided wave scan of the skull. This would allow co-registration of the bone’s ultrasonic properties with the therapeutic axis. In this work, a beamforming scheme for the excitation of guided waves in cranial bone using a transcranial transducer is described and demonstrated. These guided waves are then observed in the far field and are shown to change velocity with skull thickness.


  • Open Access

    An Adaptive Array Excitation Scheme for the Unidirectional Enhancement of Guided Waves

    by Chris Adams, Sevan Harput, David Cowell, Thomas M. Carpenter, David M. Charutz, Steven Freear

    Control over the direction of wave propagation allows an engineer to spatially locate defects. When imaging with longitudinal waves, time delays can be applied to each element of a phased array transducer to steer a beam. Because of the highly dispersive nature of guided waves (GWs), this beamsteering approach is suboptimal. More appropriate time delays can be chosen to direct a GW if the dispersion relation of the material is known. Existing techniques, however, need a priori knowledge of material thickness and acoustic velocity, which change as a function of temperature and strain. The scheme presented here does not require prior knowledge of the dispersion relation or properties of the specimen to direct a GW. Initially, a GW is generated using a single element of an array transducer. The acquired waveforms from the remaining elements are then processed and retransmitted, constructively interfering with the wave as it travels across the spatial influence of the transducer. The scheme intrinsically compensates for the dispersion of the waves, and thus can adapt to changes in material thickness and acoustic velocity. The proposed technique is demonstrated in simulation and experimentally. Dispersion curves from either side of the array are acquired to demonstrate the scheme's ability to direct a GW in an aluminum plate. The results show that unidirectional enhancement is possible without a priori knowledge of the specimen using an arbitrary pitch array transducer. The experimental results show a 34-dB enhancement in one direction compared with the other.


  • Cluster chemistry

    by Chris J. Adams, Michael I. Bruce, Brian W. Skelton, Allan H. White