GLGwangtaek Lee

Gwangtaek Lee

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Gwangtaek Lee has a total of 13 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Characterization and optimization of an ion spray air cleaner: housing material and ionizer geometry effects on clean air delivery rate

    by Gwangtaek Lee, Yewon Park, Bangwoo Han, Hak-Joon Kim

    Indoor particulate matter exposure has become a critical global health concern, and filter-based air cleaners have been widely used. However, it has critical shortcomings regarding frequent filter replacement and high energy consumption caused by the pressure drop across the filter. Electrostatic precipitator-based cleaners are a promising alternative, and the ion-spray configuration offers low pressure drop and low ozone emission. Therefore, we designed and evaluated an ion-spray ESP to maximize the clean air delivery rate (CADR). Although the local ion concentration differed by four orders of magnitude between a near-source and a far zone, the 8.3 m3 min-1 non-metal-frame lab device in a 30 m3 chamber achieved similar CADRs of 7.44 and 7.24 m3 min-1. The metal-frame CADR ranged from 5.6 to 7.4 m3 min-1 with ionizer length (0.4–15 cm) and from 5.9 to 7.1 m3 min-1 with tilt angle (0–90°), whereas the non-metal-frame CADR remained essentially constant at approximately 7.3 m3 min-1 regardless of geometry. The 40 m3 min-1 metal-frame pilot device in a 300 m3 chamber reached 29 m3 min-1 CADR at 0° tilt, and average CADRs were 23.8 m3 min-1. In addition, the ion-spray ESP exhibited a pressure drop of 13.5 Pa, which was 3.5-fold lower than that of the HEPA filter, and an ozone emission below 2 ppb. Therefore, the ion-spray ESP is expected to be an efficient low-energy, low-ozone air-cleaning system for improving indoor air quality in large spaces, offering a promising alternative to conventional filter- and two-stage ESP-based cleaners.

  • Open Access

    Chemical-free Non-Packing Scrubber–Electrochemical System for Industrial Gaseous NH3 Removal

    by Gwangtaek Lee, Bangwoo Han, Hak-Joon Kim

    Ammonia (NH3) emitted from semiconductor manufacturing is conventionally treated by packed-bed wet scrubber. However, this approach suffers from absorbent acidity depletion and high pressure drop inherent to the packing design. To overcome these limitations, an integrated non-packing scrubber-electrochemical regeneration system was developed for continuous, chemical-free NH3 removal and absorbent reuse. In the non-packing scrubber, NH3 removal reached 98% at an L/G ratio of 7 L m-3 and remained above 95% at absorbent pH < 8. However, scrubber-only operation could not maintain stable performance without chemical addition because the absorbent progressively lost acidity during NH3 absorption. With 0.005 M H2SO4, the NH3 removal efficiency decreased from >95% to ~45% and recovered to 95% only after additional acid addition. However, the integrated system with electrochemical cell maintained the absorbent under acidic conditions without external chemical dosing and sustained NH3 removal above 95% for 3 h. Under total ammonia nitrogen (TAN)-enriched conditions, the electrochemical nitrogen flux reached 250–260 g N m⁻2 d⁻1, which was comparable to or greater than the nitrogen loading from 100 ppm NH3 scrubbing, indicating that absorbed ammonium could be removed from the recirculating solution as rapidly as it was introduced. In addition, TAN was enriched above 5000 ppm, the average energy consumption was 3.7 kWh kg N⁻1. These results show that, unlike scrubber-only operation requiring repeated chemical addition, the integrated system enables stable and more energy-efficient continuous NH3 removal and recovery.

  • Open Access

    A Wearable Electronic Device With an Air Curtain Shield and Two‐Stage Curved Electrostatic Precipitation Module for Personal Respirator Protection

    by Serim S. Kwak, Kabin Kang, Gwangtaek Lee, Hak Joon Kim

    Conventional face masks suffer from limitations such as high pressure drop, discomfort, and limited reusability. To address these issues, we developed a wearable respiratory protection device (WRPD) that combines an air curtain shield with a curved electrostatic precipitation (EP) module. The curved EP module showed a high fine particle (0.3 μ m) removal efficiency of 99.3 % ± 0.6 % at −3.5 kV and generated low levels of ozone below 0.24 ppb. However, the efficiency of the EP module decreased to 85.8 % ± 0.8 % when it was integrated into the WRPD. In the WRPD, the air curtain shield efficiently blocked airborne and droplet‐sized particles with 91.6 % ± 1.8 % efficiency at flow rates exceeding 241 L/min under 0.7 m/s particle intrusion but showed limited effectiveness for submicron particles. However, the full WRPD system with both the air curtain shield and curved EP module operating achieved 94.5% removal efficiency for submicron particles and 99.8 % ± 0.2 % for larger airborne and droplet‐sized particles. The air curtain shield not only prevented ambient air mixing but also enhanced the purity of the air delivered by the curved EP module by more than 10% compared to the WRPD operated using only the EP module.

  • On-Site Test on Fine Dust Reduction in Subway Station Using Electrostatic Type Air Purifier

    by Gwangtaek Lee, Haneol Lee, So-Hee An, Yewon Park, Bangwoo Han, Yong-Jin Kim, Hak Joon Kim

    This study investigates the effect of an electrostatic-type air handling unit (ES-AHU) for improving indoor air quality at subway station. The ES-AHU features a pre-charger with carbon microfiber electrodes and a non- metallic collecting plate. It achieved particulate matter collection efficiency exceeding 90% for both PM2.5 and PM10. This performance is approximately 1.3 to 1.5 times higher than those of conventional filter-based air handling unit. In addition, the ES-AHU reduced PM2.5 concentration in the waiting room area and platform decreased by over 50%. The results of the spatial distribution analysis showed that the PM2.5 concentration in the waiting room varies depending on the location, suggesting that it is important to consider the spatial characteristics for effective air quality improvement. The ES- AHU applied in this study shows the potential to enhance air quality and promote a healthier environment for passengers by improving the existing ventilation system at subway stations.


  • Removal of Ammonium and Fluoride From Industrial Wastewater by Sonoelectrochemical Precipitation

    by Gwangtaek Lee, Yusom Choi, Yewon Park, Haneol Lee, Bangwoo Han, Yong-Jin Kim, Hak-Joon Kim

    Wastewater from the semiconductor industry typically contains substantial amounts of total ammonia nitrogen (TAN) and fluoride that can have adverse effects on the environment. The present study examined the efficacy of a sonoelectrochemical system which applies ultrasonic waves to an electrochemical process in removing these species from wastewater. Application of the sonoelectrochemical process with a current of 2 A, and a sonication frequency of 40 kHz to synthetic wastewater resulted in a TAN removal efficiency of 52.2% . pH was the main factor affecting TAN crystallization, with alkaline conditions in combination with a sonication frequency of 40 kHz being optimal for TAN removal. In terms of fluoride removal, application of the sonoelectrochemical process for 1.5 h achieved a removal efficiency of 98% at pH 7. The main precipitates obtained were Al-F complexes. The present findings indicate that the sonoelectrochemical process is a feasible and cost-effective approach for use in the recycling of industrial wastewater.


  • Absorption of nitrogen dioxide via a non-packing scrubber using a sulfite/thiosulfate complex absorbent

    by Gwangtaek Lee, Yewon Park, Jungho Hwang, Bangwoo Han, Yongjin Kim, Hak Joon Kim


  • Retrofitting of an Air Handling Unit by a Two-Stage Electrostatic Precipitator

    by Yeawan Lee, Ye-Sle Kim, Haneol Lee, Yewon Park, Gwangtaek Lee, So-Hee An, Bangwoo Han, Yong-Jin Kim, Hak-Joon Kim

    A two-stage electrostatic precipitator (ESP) was developed using carbon brush ionizers and lightweight plastic electrodes to be used in an air handling unit (AHU). In a pilot study, the developed ESP emitted near-zero ozone (2.5 collection efficiency higher than 90%. Theoretical analysis revealed that diffusion charging was as important as field charging in the particle charging mechanism. Based on the results of the pilot study, a real AHU of Yuseong Oncheon subway station, South Korea, was retrofitted with the developed ESP. In the field study, a flow distributor was required to achieve uniform flow and minimize the spatial standard deviation of the air flow velocity. Compared to a filter with a minimum efficiency reporting value (MERV) = 14, typically used for particle removal, the pressure drop decreased from 157.1 to 15.2 Pa, and the PM 2.5 collection efficiency increased from 72.7% to 75.0% by the retrofitting of the AHU. The modified quality factor improved more than three-fold, and the required power consumption to operate the device and the fan decreased from 2.49 to 0.85 kW. During ESP operation, the indoor ozone concentration increased by only 1.1 ppbv, whereas the outdoor ozone concentration increased by 30 ppbv. Thus, ESP operation in this study barely increased the indoor ozone concentration.